  • Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit recognition, Level 2: / Opener (NC) Normally open contact (NO)
  • Multifunctional safety relay module for superior diagnostics and visualisation
  • Suitable for the signal processing of outputs with contact sensors
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
  • Suitable for the signal processing of outputs with contact sensors
  • 3 safety contacts, STOP 0
  • 2 + 6 Signalling outputs

Ordering data

Note (Delivery capacity)

Niedostępne!

Replacement article number

101166107

Product type description

SRB308IT-230VAC

Article number (order number)

101158202

EAN (European Article Number)

4250116201563

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

cULus

General data

Standards

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 61508

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-78

Housing material

Tworzywo, Tworzywo termoplastyczne wzmocnione włóknem szklanym, obudowa wentylowana

Gross weight

480 g

General data - Features

Electronic Fuse

Tak

Wire breakage detection

Tak

Cross-circuit detection

Tak

Removable Terminals

Tak

Start input

Tak

Feedback circuit

Tak

Automatic reset function

Tak

Reset edge detection

Tak

Earth connection detection

Tak

Integral system diagnostics, status

Tak

Number of auxiliary contacts

2

Number of LEDs

5

Number of normally closed (NC)

2

Number of undelayed semi-conductor outputs with signaling function

6

Number of safety contacts

3

Number of signalling outputs

6

Safety classification

Vorschriften

EN IEC 60947-5-1

EN IEC 61508

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Stop-Category

0

Safety classification - Relay outputs

Performance Level, stop 0, up to

e

Category, Stop 0

4

Diagnostic Coverage (DC) Level, Stop 0

≥ 99 %

PFH value, Stop 0

2,00 x 10⁻⁸ /h

Safety Integrity Level (SIL), Stop 0, suitable for applications in

3

Mechanical data

Mechanical life, minimum

10 000 000 Operations

Mounting

montaż na standardowej szynie DIN wg EN 60715

Mechanical data - Connection technique

Terminal designations

IEC/EN 60947-1

Termination

sztywny lub elastyczny

Połączenie śrubowe M20 x 1.5

Cable section, minimum

0,25 mm²

Cable section, maximum

2,5 mm²

Tightening torque of Clips

0,6 Nm

Mechanical data - Dimensions

Width

45 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature

-25 ... +45 °C

Storage and transport temperature

-40 ... +85 °C

Resistance to vibrations

10 ... 55 Hz, amplituda 0,35 mm

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution

2

Electrical data

Frequency range

50 Hz

60 Hz

Operating voltage

230 VAC -15 % / +10 %

Rated operating voltage

230 VAC

Operating current

125 mA

Rated AC voltage for controls, 50 Hz, minimum

215 VAC

Rated control voltage at AC 50 Hz, maximum

253 VAC

Rated AC voltage for controls, 60 Hz, minimum

215 VAC

Rated control voltage at AC 60 Hz, maximum

253 VAC

Utilisation category AC-15

230 VAC

Utilisation category AC-15

1,5 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1,2 A

Electrical power consumption

3 W

Electrical power consumption

3 VA

Contact resistance, maximum

0,1 Ω

Note (Contact resistance)

w nowym stanie

Drop-out delay in case of "emergency stop", maximum

15 ms

Pull-in delay at automatic start, maximum, typically

60 ms

Pull-in delay at RESET, typically

200 ms

Material of the contacts, electrical

AgSn0, Ag-Ni, samoczyszczący, wymuszone prowadzenie

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

Dyrektywa o kompatybilności elektromagnetycznej

Status indication

Indicated operating states

Przekaźnik pozycyjny K2

Przekaźnik pozycyjny K1

Wewnętrzne napięcie robocze Ui

Przekaźnik pozycyjny K3

Other data

Note (applications)

Osłony bezpieczeństwa

Przycisk stopu awaryjnego

Linkowe wyłączniki stopu awaryjnego

Kurtyny świetlne bezpieczeństwa

Note

Note (General)

Obciążenia indukcyjne (np. styczniki, przekaźniki itp.) należy wytłumić przy pomocy odpowiedniego obwodu.

Wiring example

Note (Wiring diagram)

Schemat okablowania dla zamknietej osłony bezpieczeńatwa i stanu z wyłączonym zasilaniem.

Tabele ISD (Zintegrowanego Systemu Diagnostyczego) dla analizy wskazań błędów i ich przyczyn zamieszczono w załączniku.

Wyjścia przekaźnikowe: odpowiednie dla sterowania 2-kanałowego, dla zwiększenia pojemności lub liczby zestyków za pomocą styczników lub przekaźników o zestykach lustrzanych.

Sterownik rozpoznaje zwarcie międzykanałowe, przerwanie kabla lub upływ doziemny w obwodzie monitorowania.

Podłączyć potencjałowe wyjścia (typu p) krat/kurtyn świetlnych bezpieczeństwa do S12/S22. Urządzenia muszą mieć ten sam potencjał referencyjny.

Pokazano sterowanie 2-kanałowe dla monitorowania osłony bezpieczeństwa z dwoma zestykami, z których przynajmniej jeden zestyk posiada funkcję wymuszonego rozwarcia, z zewnętrznym przyciskiem resetu (R) i obwodem sprzężenia zwrotnego (H2). (przykład bez wykrywania zwarć międzykanałowych)

Sterowanie dwukanałowe z wykrywaniem zwarć międzykanałowych, podłączyć zestyk NC do S11/S12 i S31/S32 oraz zmostkować S21/S22

Aby uzyskać sterowanie 1-kanałowe, podłączyć zestyk NC do S11/S12 i zmostkować S31/S32

Funkcja uruchamiania / przycisk reset: Funkcja "zbocze opadające" jest programowana za pomocą przełącznika "AF" umieszczonego pod pokrywą obudowy (pozycja przełącznika = 1). Automatyczne uruchomienie jest programowane przez zmostkowanie przyłączy X3/X5 i przestawienie przełącznika "AF" na 0. Przesunięcie czasowe między kanałami wynosi ok. 100 ms. Nieskończone przesunięcie czasowe pomiędzy kanałami 1 i 2 programowane jest przez zmostkowanie przyłączy X3/X6.

F1 = bezpiecznik hybrydowy

F2 = bezpiecznik dla wyjść sygnalizacyjnych

Filtr językowy

Przykład połączeń (okablowanie elektryczne)

pobierz najnowszą wersję Adobe Reader

103007672 SRB-E-301ST
  • Plug-in screw terminals with coding
  • STOP 0 Function
  • 1 oder 2-channel control
  • Start button / Auto-start
  • 1 Auxiliary contact
  • 3 safety contacts


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220