FWS 1206 C
FWS 1206 C
- Detects standstill using 1 or 2 impulse sensors
- Uses additional standstill signal, e.g. PLC as second input channel
- 2 safety contacts
- 2 Signalling outputs
Ordering data
Note (Delivery capacity) |
Phased-out product |
Product type description |
FWS 1206 C |
Article number (order number) |
101170058 |
EAN (European Article Number) |
4030661297200 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Available until |
31.12.2024 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
BG-GS-ET-20 EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-3 BG-GS-ET-14 |
Housing material |
Plast, glasfiberarmerad termoplast, ventilerad |
Gross weight |
200 g |
General data - Features
Wire breakage detection |
Ja |
Feedback circuit |
Ja |
Reset edge detection |
Ja |
Earth connection detection |
Ja |
Integral system diagnostics, status |
Ja |
Number of LEDs |
1 |
Number of undelayed semi-conductor outputs with signaling function |
2 |
Number of safety contacts |
2 |
Number of signalling outputs |
2 |
Safety classification |
Vorschriften |
EN IEC 61508 |
Performance Level, up to |
d |
Category |
3 |
PFH value |
1,00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Mission time |
20 Year(s) |
Stop-Category |
0 |
Mechanical data
Mechanical lifetime, minimum |
20.000.000 Operations |
Mounting |
snäpps på standard-DIN-skena enligt EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
styv eller flexibel Skruvkoppling M20 x 1,5 |
Cable section, minimum |
0,2 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
22,5 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the installation space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
+0 ... +55 °C |
Storage and transport temperature |
-25 ... +70 °C |
Resistance to vibrations |
10 ... 55 Hz, amplitud 0,35 mm |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4,8 kV |
Overvoltage category |
II |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC -15 % / +15 % |
Thermal test current |
6 A |
Rated operating voltage |
24 VDC |
Rated AC voltage for controls, 50 Hz, minimum |
20.4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26.4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20.4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26.4 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Electrical power consumption, maximum |
5 W |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
i nyskick |
Material of the contacts, electrical |
Ag-Ni 10 och 0,2 µm guldpläterat |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
3 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
2 A |
Switching capacity, minimum |
10 VDC |
Switching capacity, minimum |
10 mA |
Switching capacity, maximum |
250 VAC |
Switching capacity, maximum |
8 A |
Electrical data - Digital inputs
Input signal, HIGH Signal "1" |
10 … 30 VDC |
Input signal, LOW Signal "0" |
0 … 2 VDC |
Conduction resistance, maximum |
40 Ω |
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum |
24 VDC |
Switching capacity, maximum |
2 A |
Integral system diagnosis (ISD)
Note (ISD -Faults) |
Följande fel registreras av säkerhetsmodulerna och indikeras av ISD. |
Faults |
Säkerhetsreläet går inte att aktivera eller deaktivera Fel på ingångskretsarna till säkeretreläet De induktiva givarna fungerar inte Fel på en kanal som utvärderas Avbrott i anslutningarna till de induktiva givarna |
Other data
Note (applications) |
säker stilleståndsövervakning |
Note
Note (General) |
Induktiva laster (t.ex. kontaktorer, reläer etc.) måste dämpas med hjälp av en lämplig krets. |
Wiring example
Note (Wiring diagram) |
Om endast en induktiv givare är ansluten till stilleståndsvakten måste frekvenserna för stillestånd vara identiska och ingångarna X1 och X2 måste därför byglas. |
Språk filter
Datablad
Driftsinstruktion och EU-försäkran om överensstämmelse
UL-certifikat
Info
Kopplingsexempel (elektr. trådning)
SISTEMA-VDMA Bibliotek/Library
Ladda ned senaste versionen av Adobe reader
Produktbild (singelfoto i katalog)
Kopplingsexempel
103014754 SRB-E-302FWS-TS
- 2 Safety contacts, 1 Safety Output
- Plug-in screw terminals with coding
- 1 Signalling output - status safety module
- 1 Signalling output - failure massage dynamic
- Detects standstill using 1 or 2 impulse sensors
- additional standstill signal, e.g. PLC as second input channel
- 2-channel time monitoring
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | FWS 1206 |
Type: | See ordering code |
Description of the component: | Fail-safe standstill monitor |
Relevant Directives: | Machinery Directive | 2006/42/EC |
EMC-Directive | 2014/30/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 60947-5-1:2017 + AC:2020 EN ISO 13849-1: 2015 EN ISO 13849-2: 2012 |
Notified body, which approved the full quality assurance system, referred to in Appendix X, 2006/42/EC: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, August 4, 2023 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Alla data och värden har kontrollerats noga. Bilder kan avvika från originalet. Ytterligare tekniska data finns i manualen. Tekniska ändringar och fel förbehålles.
Genererat den 2025-08-24 08:48