- Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit recognition, Level 2: / Opener (NC) Normally open contact (NO)
- Multifunctional safety relay module for superior diagnostics and visualisation
- Suitable for the signal processing of outputs with contact sensors
- Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
- Suitable for the signal processing of outputs with contact sensors
- 3 safety contacts, STOP 0
- 2 + 6 Signalling outputs
Ordering data
Note (Delivery capacity) |
Ej tillgänglig! |
Replacement article number |
101166107 |
Product type description |
SRB308IT-230VAC |
Article number (order number) |
101158202 |
EAN (European Article Number) |
4250116201563 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
Plast, glasfiberarmerad termoplast, ventilerad |
Gross weight |
480 g |
General data - Features
Electronic Fuse |
Ja |
Wire breakage detection |
Ja |
Cross-circuit detection |
Ja |
Removable Terminals |
Ja |
Start input |
Ja |
Feedback circuit |
Ja |
Automatic reset function |
Ja |
Reset edge detection |
Ja |
Earth connection detection |
Ja |
Integral system diagnostics, status |
Ja |
Number of auxiliary contacts |
2 |
Number of LEDs |
5 |
Number of normally closed (NC) |
2 |
Number of undelayed semi-conductor outputs with signaling function |
6 |
Number of safety contacts |
3 |
Number of signalling outputs |
6 |
Safety classification |
Standards |
EN IEC 60947-5-1 EN IEC 61508 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
e |
Category, Stop 0 |
4 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
PFH value, Stop 0 |
2,00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Mechanical data
Mechanical lifetime, minimum |
10.000.000 Operations |
Mounting |
snäpps på standard-DIN-skena enligt EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
styv eller flexibel Skruvkoppling M20 x 1,5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
45 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the installation space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +45 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10 ... 55 Hz, amplitud 0,35 mm |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
230 VAC -15 % / +10 % |
Rated operating voltage |
230 VAC |
Operating current |
125 mA |
Rated AC voltage for controls, 50 Hz, minimum |
215 VAC |
Rated control voltage at AC 50 Hz, maximum |
253 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
215 VAC |
Rated control voltage at AC 60 Hz, maximum |
253 VAC |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
1,5 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
1,2 A |
Electrical power consumption |
3 W |
Electrical power consumption |
3 VA |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
i nyskick |
Drop-out delay in case of "emergency stop", maximum |
15 ms |
Pull-in delay at automatic start, maximum, typically |
60 ms |
Pull-in delay at RESET, typically |
200 ms |
Material of the contacts, electrical |
AgSn0, AgNi, självrengörande, tvångsstyrd |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
EMC-Directive |
Status indication
Indicated operating states |
Positionsrelä K2 Positionsrelä K1 Intern driftspänning Ui Positionsrelä K3 |
Other data
Note (applications) |
Skyddsanordning Nödstoppsknapp Linnödstopp Säkerhetsljusridå |
Note
Note (General) |
Induktiva laster (t.ex. kontaktorer, reläer etc.) måste dämpas med hjälp av en lämplig krets. |
Wiring example
Note (Wiring diagram) |
Kopplingsdiagrammet visas med skyddsdörrarna stängda och i strömlöst tillstånd. ISD-tabellerna (integrerad systemdiagnos) för analys av felindikationerna och deras orsaker visas i bilagan. Reläutgångar: Lämpliga för 2 kanalstyrning, för utökning av antalet kontakter med hjälp av kontaktorer eller reläer med positivt styrda kontakter. Styrenheten identifierar kortslutning, kabelbrott och jordfel i övervakningskretsen. Anslut utgångar av p-typ på ljusbommar/ljusridåer till S12/S22. Enheterna måste ha samma referenspotential. 2-kanalig övervakning för en skyddsdörr med två brytare varav minst en kontakt har tvångsbrytning, med extern reset (R) och återkopplingskrets (H2). (exempel utan kortslutningsövervakning) För tvåkanalsstyrning med kortslutningsövervakning ansluts en br-kontakt till S11/S12 och S31/S32 samt bygla S21/S22 Anslut NC-kontakten för S11/S12 vid 1-kanalig styrning och bygla S21/S22 i S31/S32 Resetfunktion: Reset på bakflank ställs in med hjälp av ”AF”-brytaren som är placerad under locket (brytarposition = 1). Automatiska reset ställsn in genom bygling av polerna X3/X5 och genom att ”AF”-brytaren sätts till 0. Tidsförskjutningen mellan kanalerna är ungefär 100 ms. En oändlig tidsförskjutning mellan kanal 1 och 2 programmeras genom bygling av polerna X3/X6. F1 = hybridsäkring F2 = Säkring för signalutgångar |
Språk filter
Datablad
Driftsinstruktion och EU-försäkran om överensstämmelse
UL-certifikat
Kopplingsexempel (elektr. trådning)
Kraft-Väg diagram
Ladda ned senaste versionen av Adobe reader
Produktbild (singelfoto i katalog)
Kopplingsexempel
Kopplingsexempel
Kopplingsexempel
Symbol (teknisk standard)
103007672 SRB-E-301ST
- Plug-in screw terminals with coding
- STOP 0 Function
- 1 oder 2-channel control
- Start button / Auto-start
- 1 Auxiliary contact
- 3 safety contacts