EX-SLC440-ER-0650-30
EX-SLC440-ER-0650-30
- Ex-Zone 1 and 21
- Resolution 14 and 30 mm
- Range up to 20m
- Protected mode
- Integrated contactor control
- Beam coding
Ordering data
Product type description |
EX-SLC440-ER-0650-30 |
Article number (order number) |
103047632 |
EAN (European Article Number) |
4030661619125 |
eCl@ss number, version 12.0 |
27-27-27-04 |
eCl@ss number, version 11.0 |
27-27-27-04 |
eCl@ss number, version 9.0 |
27-27-27-04 |
ETIM number, version 7.0 |
EC002549 |
ETIM number, version 6.0 |
EC002549 |
Approvals - Standards
Certificates |
ATEX |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN 60079-1 EN 60079-28 EN 60079-31 |
Explosion protection zones |
1 21 |
Explosion protection category |
2G 2D |
Explosion protection designation |
D II 2G Ex db op is IIA T6 Gb D II 2D Ex op is tb IIIC T80°C Db |
General data
Standards |
EN IEC 61496-2 EN IEC 62061 EN ISO 13849-1 EN IEC 61496-1 |
Housing material |
Shatterproof glass |
Reaction time, maximum |
10 ms |
Reaction time with beam coding A, maximum |
15 ms |
General data - Features
Restart interlock (manual reset) |
Evet |
Contactor control integrated |
Evet |
Beam coding available |
Evet |
Blanking function |
Evet |
7-segment display |
Evet |
Integral system diagnostics, status |
Evet |
Integral system diagnostics |
Evet |
Number of fail-safe digital outputs |
2 |
Number of beams |
32 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 62061 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
5,14 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Safety type in accordance with IEC 61496-1 |
4 |
Mechanical data
Height of the protection field |
650 mm |
Range, protection field, minimum |
0,3 m |
Range, protection field, maximum |
10 m |
Wave length of the laserdiode |
850 nm |
Mechanical data - Connection technique
Termination |
Konektör |
Terminal connector, Recipient |
Konektör fişi M12 8-kutup |
Terminal, Connector, Transmitter |
Konektör fişi M12 4-kutup |
Mechanical data - Dimensions
Width of sensor |
100 mm |
Ambient conditions
Degree of protection |
IP66 |
Ambient temperature |
-25 ... +50 °C |
Storage and transport temperature |
-25 ... +70 °C |
Electrical data
Switching voltage OSSD, HIGH signal |
24 V |
Electrical data - Safety digital outputs
Output current, (fail-safe output), maximum |
0,25 A |
Design of control elements |
short-circuit proof, p-type |
Scope of delivery
Scope of delivery |
2 montaj dirsekli set |
Accessory
Recommended safety switchgear |
SRB-E 301 |
Note
Note (General) |
Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |
Dil filtresi
Veri sayfası
Çalışma Talimatları ile Uygunluk beyanı
ATEX Certificate
Adobe Reader’ın son sürümünü indirin
Ürün resmi (katalog özel fotoğraf)
ID: kxslc4f01
| 863,1 kB | .jpg | 352.778 x 968.375 mm - 1000 x 2745 px - 72 dpi
| 97,3 kB | .png | 74.083 x 203.2 mm - 210 x 576 px - 72 dpi
| 24,1 kB | .jpg | 45.156 x 123.472 mm - 128 x 350 px - 72 dpi
| 918,1 kB | .jpg | 352.778 x 968.375 mm - 1000 x 2745 px - 72 dpi
| 129,8 kB | .png | 74.083 x 203.2 mm - 210 x 576 px - 72 dpi
| 60,3 kB | .png | 45.156 x 123.472 mm - 128 x 350 px - 72 dpi
Ürün resmi (katalog özel fotoğraf)
Boyutsal resim temel bileşeni
Boyutsal resim temel bileşeni
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | Series EX-SLC440 Series EX-SLG440 |
Type: | See ordering code |
Marking: | D II 2G Ex db op is IIA T6 Gb D II 2D Ex op is tb IIIC T80°C Db |
Description of the component: | Safety light curtain / safety light grid |
Relevant Directives: | Machinery Directive 1) | 2006/42/EC |
EMC-Directive | 2014/30/EU | |
Explosion Protection Directive (ATEX) 2) | 2014/34/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 61496-1:2013 EN 61496-2:2013 ISO 13849-1:2015 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 EN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-28:2015 EN 60079-31:2014 |
Notified body, which approved the full quality assurance system, referred to Appendix IV, 2014/34/EU: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
Notified body for Type Examination: | 1) TÜV NORD CERT GmbH | 2) TÜV CYPRUS |
Langemarckstr. 20, 45141 Essen | Papaflessa 2, 2235 Latsia, Nicosia | |
Germany | Cyprus | |
ID n°: 0044 | ID n°: 2261 |
Type Examination Certificate: | 1) 44 205 16019910 | 2) TÜV CY 22 ATEX 0206673 X |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, January 13, 2023 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Veriler ve ayrıntılar dikkatli bir şekilde kontrol edilmişlerdir. Görüntüler orijinalden farklı olabilir. Daha fazla teknik veri kılavuzda bulunabilir. Teknik değişiklikler ve hatalar olabilir.
Udarbejdet d. 26.04.2025 02:34