- UNIVERSAL Gateway for the series-wiring of the diagnostic signals of safety
switchgear with integrated SD interface. - Comprehensive volumes of status and diagnostic data of the SD devices are transmitted to the control system through the field bus interface.
- Series-wiring of the diagnostic lines of max. 31 safety switchgear
- Series-wiring of different devices possible
- Reduced wiring efforts and costs as a result of the series-wiring of the safety channels and the diagnostic cables in the field.
- Automatic addressing of the safety switchgear in the SD interface
Ordering data
Product type description |
SD-I-U-PN |
Article number (order number) |
101209434 |
EAN (European Article Number) |
4030661448909 |
eCl@ss number, version 12.0 |
27-23-02-06 |
eCl@ss number, version 11.0 |
27-23-02-06 |
eCl@ss number, version 9.0 |
27-23-02-08 |
ETIM number, version 7.0 |
EC001099 |
ETIM number, version 6.0 |
EC001099 |
Approvals - Standards
Certificates |
cULus |
General data
Gross weight |
200 g |
General data - Features
Integral system diagnostics, status |
Evet |
Number of LEDs |
1 |
Mechanical data
Mounting |
EN 60715 e uygun standart DIN rayının üzerine kilitlenir |
Mechanical data - Connection technique
Termination |
Kafes kelepçeleri |
Mechanical data - Dimensions
Width |
50 mm |
Height |
100 mm |
Depth |
80 mm |
Ambient conditions
Degree of protection of the enclosure |
IP20 |
Ambient temperature |
+0 ... +55 °C |
Storage and transport temperature |
-25 ... +75 °C |
Relative humidity, minimum |
30 % |
Relative humidity, maximum |
85 % |
Note (Relative humidity) |
yoğuşmaz |
Resistance to vibrations |
10 ... 57 Hz, Genlik 0.35 mm 57 ... 150 Hz, ile 5 g |
Restistance to shock |
10 g |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 V |
Rated impulse withstand voltage Uimp |
0,5 kV |
Overvoltage category |
II |
Degree of pollution |
2 |
Electrical data
Operating voltage |
24 VDC -15 % / +20 % |
Rated operating voltage |
24 VDC |
Operating current |
500 mA |
Electrical data - Communication protocols
Feldbus Protokoll |
PROFINET IO |
Electrical data - Electromagnetic compatibility (EMC)
Electromagnetic compatibility |
EN 61000-4-2 EN 61000-4-4 EN 61000-4-5 |
Interfering radiation |
IEC 61000-6-4 (2002) |
EMC rating |
EN 61000-4-3 EN 61000-4-6 |
Other data
Note (applications) |
Güvenlik sensörü Koruma sistemi |
Dil filtresi
Veri sayfası
Çalışma Talimatları ile Uygunluk beyanı
UL Sertifikası
Veri sayfası (geçici PDF)
Cihaz açıklama dosyaları
Adobe Reader’ın son sürümünü indirin
Ürün resmi (katalog özel fotoğraf)
Kablo döşeme örneği
Uygulama notu
ID: p-sd-i-u-pn
Video ID: SD-Interface-Mr-Safety
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | SD-I-U-… |
Type: | See ordering code |
Description of the component: | UNIVERSAL gateway for serial diagnostic (SD-I-U-..) |
Relevant Directives: | EMC-Directive | 2014/30/EU |
RoHS-Directive | 2011/65/EU |
Applied standards: | DIN EN 61000-6-2:2006 DIN EN 61000-6-4:2011 EN 61326-3-1:2008 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, November 12, 2018 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Veriler ve ayrıntılar dikkatli bir şekilde kontrol edilmişlerdir. Görüntüler orijinalden farklı olabilir. Daha fazla teknik veri kılavuzda bulunabilir. Teknik değişiklikler ve hatalar olabilir.
Udarbejdet d. 17.08.2025 16:41