schmersal_s_icon.png

AZM 200 B SK-T-1P2PWA

项目编号: 101195441

下载

追踪备件 CAD数据
计划 数据
CADENAS CAD数据
产品描述:

AZM 200(1)(2)-T-(3)(4)


(1)
防护装置锁定监控 >
B操动件,受监控

(2)
SK螺丝端子
CC弹簧滑轮连接
ST1连接器M23 x 1,(8+1 芯)
ST2连接器M12 x 1,8 芯

(3)
1P2P1 串联诊断输出以及2 P型安全输出
1P2PW与1P2P相同,组合诊断信号:防护系统关闭且联锁装置锁定
SD2P串联诊断输出以及2个P型安全输出

(4)
通电开锁
A 通电上锁
并非所有根据本订单代码可能的组件变体都可用和/或在技术上可行。
  • Actuator monitored
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Max. length of the sensor chain 200 m
  • Self-monitoring series-wiring
  • 3 LEDs to show operating conditions
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
  • Intelligent diagnosis
  • Manual release

Ordering data

Note (Delivery capacity)

不支持!

Product type description

AZM 200 B SK-T-1P2PWA

Article number (order number)

101195441

EAN (European Article Number)

4030661360782

eCl@ss number, version 12.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 9.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

cULus

General data

Standards

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 61508

Working principle

感应

Housing material

玻璃纤维,加强型热塑塑料

Reaction time, maximum

60 ms

Duration of risk, maximum

120 ms

Gross weight

550 g

General data - Features

Power to lock

Actuator monitored

Manual release

Short circuit detection

Cross-circuit detection

Series-wiring

Safety functions

Integral system diagnostics, status

Number of safety contacts

2

Safety classification

Vorschriften

EN IEC 60947-5-3

EN IEC 61508

Mission time

20 Year(s)

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

4.00 x 10⁻⁹ /h

PFD value

1.00 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Holding force FZh in accordance with EN ISO 14119

2,000 N

Note (clamping force FZh)

1,000 N 当使用↲AZ/ AZ/AZM201-B30操动件,用于室内.

Holding force Fmax, maximum

2,600 N

Note (clamping force Fmax)

1,300 N 当使用↲AZ/ AZ/AZM201-B30操动件,用于室内.

Latching force

30 N

Actuating speed, maximum

0.2 m/s

Tightening torque of the fastening screws for the housing cover, minimum

0.7 Nm

Tightening torque of the fastening screws for the housing cover, maximum

1 Nm

Note

Torx T10

Mechanical data - Connection technique

Termination

螺丝端子 M20 x 1.5

Cable section, minimum

.25 mm²

Cable section, maximum

1.5 mm²

Note

包括导体套管在内的所有指标。

Wire cross-section, minimum

23 AWG

Wire cross-section, maximum

15 AWG

Allowed type of cable

实心单线

实心多导线

可调

Mechanical data - Dimensions

Length of sensor

50 mm

Width of sensor

40 mm

Height of sensor

220 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature

-25 ... +50 °C

Storage and transport temperature

-25 ... +85 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Note (Relative humidity)

无冷凝

Resistance to vibrations

10 ... 55 Hz,振幅 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 %

No-load supply current I0, typical

600 mA

Rated operating voltage

24 VDC

Operating current

50 mA

Time to readiness, maximum

4,000 ms

Switching frequency, approx.

1 Hz

Electrical data - Magnet control

Switching thresholds

-3 V … 5 V (Low)

15 V … 30 V (High)

Magnet switch-on time

100 %

Electrical data - Safety digital inputs

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24 V

5 mA

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Voltage drop Ud, maximum

4 V

Leakage current Ir, maximum

0.5 mA

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.25 A

Electrical data - Diagnostic outputs

Voltage drop Ud, maximum

4 V

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.05 A

Status indication

Note (LED switching conditions display)

工作状态:LED绿色

错误 / 功能故障:LED红色

供电电压 UB:LED 绿色

Scope of delivery

Scope of delivery

操动件#必须单独订购.

AZM200用的三角钥匙

Accessory

Recommendation (actuator)

AZ/AZM 200-B1

Note

Note (General)

只要操动件保持插入在电磁安全锁中,已解锁的防护门会重新锁定。在这种情况下,安全输出将重新启用,因此不能打开安全防护装置。

103013911 AZM201B-SK-T-1P2PW-A
  • Actuator monitored
  • Power to lock
  • Thermoplastic enclosure
  • Max. length of the sensor chain 200 m
  • Self-monitoring series-wiring
  • Coding in accordance to ISO 14119 by using RFID-Technology
  • 3 LEDs to show operating conditions
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
  • Suitable for hinged and sliding guards
  • Intelligent diagnosis
  • Manual release
  • Protection class IP66, IP67
  • High holding force 2000
  • symmetrical construction form, assembly on 40mm profiles
  • OSSD safety outputs
  • Emergency exit / Emergency release suitable for retrofitting

EU Conformity Declaration
EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:AZM 200
Type:See ordering code
Description of the component:Interlocking device with electromagnetic interlock for safety functions
Relevant Directives:Machinery Directive2006/42/EC
 EMC-Directive2014/30/EU
 RoHS-Directive2011/65/EU
Applied standards:EN 60947-5-3:2013
ISO 14119:2013
EN ISO 13849-1:2015
EN 61508 parts 1-7:2010
EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Notified body for Type Examination:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
EC-Type Examination Certificate:01/205/5122.02/20
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, May 12, 2020
  GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

所涉及的详细信息和数据已经过仔细检查。 图像可能与原始图像有所不同。 您可在说明书中进一步获得技术数据。 可能会有技术修改和错误。

生成日期 2025/4/28 上午7:49