MS-AZM 200 D ST3-T-1P2P2P-2568
MS-AZM 200 D ST3-T-1P2P2P-2568
Produkt-Typbezeichnung: AZM 200D(1)-T-1P2P2P(2) |
(1) | |
SK | Schraubklemmen |
CC | Federkraftklemme |
ST1 | Steckeranschluss M23, (8+1-polig) |
ST2 | Steckeranschluss M12, 8-polig |
ST3 | Einbaustecker M23, 12-polig |
(2) | |
ohne | Ruhestromprinzip |
A | Arbeitsstromprinzip |
- Guard locking monitored
- Thermoplastic enclosure
- Electronic contact-free, coded system
- Max. length of the sensor chain 200 m
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Intelligent diagnosis
- Manual release
Ordering data
NOTE_DELIV_CPTY |
Nicht mehr lieferbar! |
PM_TYPE_NAME |
MS-AZM 200 D ST3-T-1P2P2P-2568 |
PM_ORDER_NUMBER |
103006851 |
SAP_EAN |
4030661443348 |
CODE_ECLASS_V12P0 |
27-27-26-03 |
CODE_ECLASS_V11P0 |
27-27-26-03 |
CODE_ECLASS_V09P0 |
27-27-26-03 |
CODE_ETIM_V07P0 |
EC002593 |
CODE_ETIM_V06P0 |
EC002593 |
General data
NORM_STANDARD |
EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 61508 |
CODE_GENERAL_INFO |
Universelle Codierung |
CODE_CODING_LEVEL_ISO14119 |
gering |
DESIGN_ACTIVE_PRINCIPLE |
induktiv |
MAT_HOUSING |
Kunststoff, glasfaserverstärkter Thermoplast |
TIME_RESPONSE_MAX |
60 |
TIME_DURAT_OF_RISK_MAX |
120 |
SAP_WEIGHT_GROSS |
720 |
General data - Features
YN_PWR_TO_UNLOCK |
Ja |
YN_ACT_MONITORING |
Ja |
YN_INTLK_MONITORING |
Ja |
YN_AUX_RELEASE |
Ja |
YN_SHORT_CIRCUIT_DETECT |
Ja |
YN_FIT_FOR_SAFE_FUNC |
Ja |
YN_INTEGR_DISPLAY_STATUS |
Ja |
NUM_OF_SAFE_CONT |
4 |
Safety classification |
SAFE_NORM_STANDARD |
EN IEC 60947-5-3 EN IEC 61508 |
Safety classification - Interlocking function
SAFE_PERFORM_LEVEL_INTLK |
e |
SAFE_CAT_INTLK |
4 |
SAFE_PFH_VALUE_INTLK |
4,00 x 10⁻⁹ |
SAFE_SIL_INTLK |
3 |
SAFE_MISSION_TIME_INTLK |
20 |
Safety classification - Interlocking function 2 |
SAFE_PERFORM_LEVEL_INTLK_2 |
d |
SAFE_CAT_INTLK_2 |
3 |
SAFE_PFH_VALUE_INTLK_2 |
1,00 x 10⁻⁷ |
SAFE_SIL_INTLK_2 |
2 |
SAFE_MISSION_TIME_INTLK_2 |
20 |
Mechanical data
DESIGN_MECH_LIFETIME_SWITCH_MIN |
1.000.000 |
FORCE_HOLDING_ISO14119 |
2.000 |
NOTE_FORCE_HOLDING_ISO14119 |
1.000 N in Verbindung mit einem Betätiger AZ/AZM201-B30 für Innenanbau. |
FORCE_HOLDING_MAX |
2.600 |
NOTE_FORCE_HOLDING_MAX |
1.300 N in Verbindung mit einem Betätiger AZ/AZM201-B30 für Innenanbau. |
FORCE_LATCH |
30 |
MOTION_ACT_SPEED_MAX |
0,2 |
TRQ_TIGHTEN_SCREW_HOUSING_COVER_MIN |
0,7 |
TRQ_TIGHTEN_SCREW_HOUSING_COVER_MAX |
1 |
NOTE_TRQ_TIGHTEN_SCREW_HOUSING_COVER |
Torx T10 |
Mechanical data - Connection technique
NOTE_LENGTH_SENSOR_CHAIN_MAX |
Leitungslänge und Leitungsquerschnitt verändern den Spannungsfall in Abhängigkeit vom Ausgangsstrom |
REVIEW_ELEC_WIRING_GENERAL |
Steckverbinder M23, 12-polig |
ELEC_CABLE_SECTION_MIN |
0,25 mm² |
ELEC_CABLE_SECTION_MAX |
1,5 mm² |
NOTE_ELEC_CABLE_SECTION |
Alle Angaben einschließlich Aderendhülsen. |
DIM_DIAM_AWG_MIN |
23 |
DIM_DIAM_AWG_MAX |
15 |
Mechanical data - Dimensions
DIM_LENGTH_SENSOR |
50 |
DIM_WIDTH_SENSOR |
40 |
DIM_HEIGHT_SENSOR |
220 |
Ambient conditions
DESIGN_IP_CLASS_GENERAL |
IP67 |
TEMP_AMB_GPV |
-25 ... +60 °C |
TEMP_STORAGE_AND_TRANSPORT_GPV |
-25 ... +85 °C |
REVIEW_RESIST_VIBRAT_EN60068_2_6 |
10 … 55 Hz, Amplitude 1 mm |
REVIEW_RESTIST_TO_SHOCK |
30 g / 11 ms |
DESIGN_PROTECT_CLASS_ROMAN |
II |
Ambient conditions - Insulation values
VOLT_RATED_INSULAT |
32 VDC |
VOLT_RATED_IMPULSE_WITHSTAND |
0,8 |
DESIGN_OVERVOLT_CAT_VDE100_ROMAN |
III |
DESIGN_DEG_OF_POLLUT_VDE100 |
3 |
Electrical data
VOLT_OPERAT_GPV |
24 VDC -15 % / +10 % |
CURR_NO_LOAD_CURR |
500 |
VOLT_RATED_OPERAT_DC |
24 |
CURR_RATED_OPERAT |
1.200 |
DIM_LENGTH_CABLE_MAX |
200 |
TIME_TO_READINESS_MAX |
4.000 |
TIME_SWITCH_FREQ_CA |
1 |
Electrical data - Magnet control
ELEC_SWITCH_THRESHOLDS_MAGNET |
-3 V … 5 V (Low) 15 V … 30 V (High) |
TIME_ON_DUTY_MAGNET |
100 |
Electrical data - Safety digital outputs
VOLT_DROP_SDOUT_MAX |
4 |
CURR_LEAKAGE_SDOUT_MAX |
0,5 |
VOLT_UTILISAT_CAT_DC13_SDOUT |
24 |
CURR_UTILISAT_CAT_DC13_SDOUT |
0,25 |
NOTE_UTILISAT_CAT_DC13_SDOUT |
Gilt für die Ausgänge Y1 und Y2 |
Electrical data - Diagnostic outputs
CURR_RATED_OPERAT_DIAGN_OUT |
100 |
VOLT_DROP_DIAGN_OUT_MAX |
4 |
VOLT_UTILISAT_CAT_DC13_DIAGN_OUT |
24 |
CURR_UTILISAT_CAT_DC13_DIAGN_OUT |
0,05 |
Status indication
NOTE_LED_STATUS_INDICAT |
Betriebszustand: gelbe LED Fehler Funktionsstörung: rote LED Versorgungsspannung UB: grüne LED |
Scope of delivery
SCOPE_OF_DELIV_GENERAL |
Der Betätiger ist nicht im Lieferumfang enthalten. Dreikantschlüssel für AZM 200 |
Accessory
RECOMM_ACT |
AZ/AZM 200-B1 |
Note
NOTE_GENERAL |
Die entsperrte Schutzeinrichtung kann, solange die Betätigereinheit in der Sicherheitszuhaltung eingeführt bleibt, wieder gesperrt werden. Die Sicherheitsausgänge werden erneut eingeschaltet, somit ist ein Öffnen der Schutzeinrichtung nicht erforderlich. |
NOTE_YN_ACT_MONITORING |
Sicherheitsausgänge Y1, Y2 |
NOTE_YN_INTLK_MONITORING |
Sicherheitsausgänge Y3, Y4 |
Sprachfilter
Datenblatt
Betriebsanleitung und Konformitätserklärung
Info
Broschüre
SISTEMA-VDMA Bibliothek/Library
Download der aktuellen Version von Adobe Reader
Produktbild (Katalogeinzelphoto )
Maßzeichnung Grundgerät
Schaltungsbeispiel
施迈赛工业开关制造(上海)有限公司, 上海市青浦区漕盈路3336号,
Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.
Generiert am: 06.08.2025, 19:57