CSS 12-34-V-SD-M-L

Artikelnummer: 101181062

  • 1 x Pre-wired cable 8-pole
  • Actuation from top
  • serial diagnostic output
  • Max. 31 sensors can be wired in series.
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Misaligned actuation possible
  • 27 mm x 108.2 mm x 35 mm
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

Ordering data

Note (Delivery capacity)

Nicht mehr lieferbar!

Product type description

CSS 12-34-V-SD-M-L

Article number (order number)

101181062

EAN (European Article Number)

4030661314860

eCl@ss number, version 12.0

27-27-46-01

eCl@ss number, version 11.0

27-27-24-03

eCl@ss number, version 9.0

27-27-24-03

ETIM number, version 7.0

EC001829

ETIM number, version 6.0

EC001829

Approvals - Standards

Certificates

TÜV

cULus

UKCA

General data

Standards

EN IEC 60947-5-3

Working principle

induktiv

Housing construction form

Quader

Installation conditions (mechanical)

nicht bündig

Sensor topology

Reihenschaltungsgerät

Housing material

Kunststoff, glasfaserverstärkter Thermoplast

Active area

Kunststoff, glasfaserverstärkter Thermoplast

Reaction time, maximum

30 ms

Duration of risk, maximum

60 ms

Gross weight

300 g

General data - Features

Serial diagnostics

Ja

Diagnostic output

Ja

Short circuit detection

Ja

Cross-circuit detection

Ja

Safety functions

Ja

Cascadable

Ja

Integral system diagnostics, status

Ja

Number of LEDs

3

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of series-wiring of sensors

31

Safety classification

Standards

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Performance Level, up to

e

Category

4

PFH value

3,60 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Actuating panels

kopfseitige Betätigung

Active area

vorderseitig

Switching distance actuator

Betätiger CST 34-V-1: 12 mm (Schaltabstand typisch Sn)

Betätiger CST 34-V-1: 10 mm (gesicherter Schaltabstand EIN Sao)

Betätiger CST 34-V-1: 15 mm (gesicherter Schaltabstand AUS Sar)

Betätiger CST 34-S-1 / CST 34-S-3: 15 mm (Schaltabstand typisch Sn)

Betätiger CST 34-S-1 / CST 34-S-3: 13 mm (gesicherter Schaltabstand EIN Sao)

Betätiger CST 34-S-1 / CST 34-S-3: 18 mm (gesicherter Schaltabstand AUS Sar)

Betätiger CST 34-S-2: 10 mm (Schaltabstand typisch Sn)

Betätiger CST 34-S-2: 8 mm (gesicherter Schaltabstand EIN Sao)

Betätiger CST 34-S-2: 16 mm (gesicherter Schaltabstand AUS Sar)

Betätiger CST 180-1 / CST 180-2: 12 mm (typischer Schaltabstand Sn)

Betätiger CST 180-1 / CST 180-2: 10 mm (gesicherter Schaltabstand EIN Sao)

Betätiger CST 180-1 / CST 180-2: 16 mm (gesicherter Schaltabstand AUS Sar)

Mechanical data - Switching distances according EN IEC 60947-5-3

Hysteresis (Switching distance), maximum

1,5 mm

Repeat accuracy R

0,5 mm

Note (Repeat accuracy R)

Seitlicher Versatz: Die Kopffläche erlaubt einen Querversatz (z) von max. ± 8 mm. siehe Abbildung: Funktionsweise

Mechanical data - Connection technique

Note (length of the sensor chain)

Leitungslänge und Leitungsquerschnitt verändern den Spannungsfall in Abhängigkeit vom Ausgangsstrom

Note (series-wiring)

Anzahl der Geräte unbegrenzt, externen Leitungsschutz beachten, max. 31 Geräte bei serieller Diagnose SD

Length of cable

2 m

Termination

Kabel (Y-UL 2517), 8-polig

Cable section, maximum

8 x 0,35 mm²

Wire cross-section

22 AWG

Cable type

LiYY

Mechanical data - Dimensions

Length of sensor

35 mm

Width of sensor

27 mm

Height of sensor

108,2 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature

-25 ... +70 °C

Storage and transport temperature

-25 ... +85 °C

Resistance to vibrations

10 … 55 Hz, Amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0,8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

No-load supply current I0, typical

100 mA

Operating current

600 mA

Required rated short-circuit current

100 A

Utilisation category DC-12

24 VDC

Utilisation category DC-12

0,05 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

0,05 A

Switching frequency, approx.

3 Hz

Utilisation category DC-12

24 VDC / 0,05 A

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0,25 A

Design of control elements

p-schaltend

Voltage drop Ud, maximum

0,5 V

Leakage current Ir, maximum

0,5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,25 A

Electrical data - Diagnostic outputs

Design of control elements

p-schaltend

Voltage drop Ud, maximum

5 V

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,05 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,05 A

Electrical data - Serial diagnostic SD

Designation, Serial diagnostic SD

OUT

Operation current

150 mA

Design of control elements

kurzschlussfest, p-schaltend

Wiring capacitance

50 nF

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

EMC rating

IEC 61000-6-2

Pin assignment

PIN 1

A1 Ue: braun

PIN 2

X1 Sicherheitseingang 1: weiß

PIN 3

A2 GND: blau

PIN 4

Y1 Sicherheitsausgang 1: schwarz

PIN 5

SD serieller Diagnoseausgang: grau

PIN 6

X2 Sicherheitseingang 2: violett

PIN 7

Y2 Sicherheitsausgang 2: rot

PIN 8

IN serieller Diagnoseeingang: rosa

Scope of delivery

Scope of delivery

Der Betätiger ist nicht im Lieferumfang enthalten.

Accessory

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Note

Note (General)

Anforderungen an die Auswertung: Zweikanaliger Sicherheitseingang, geeignet für p-schaltende Sensoren mit Schließerfunktion. Die Funktionstests der Sensoren mit zyklischem Abschalten der Sensorausgänge für max. 0,5 ms müssen von der Auswertung toleriert werden. Eine Querschlusserkennung in der Auswertung ist nicht notwendig.

Sprachfilter

Schaltungsbeispiel (elektr. Verdrahtung)

Download der aktuellen Version von Adobe Reader

EU-Konformitätserklärung LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Erklärung:Hiermit erklären wir, dass die nachfolgend aufgeführten Bauteile aufgrund der Konzipierung und Bauart den Anforderungen der unten angeführten Europäischen Richtlinien entsprechen.
Bezeichnung des Bauteils:CSS 34
Typ:siehe Typenschlüssel
Beschreibung des Bauteils:Berührungslos wirkender Sicherheits-Sensor
Einschlägige Richtlinien:Maschinenrichtlinie2006/42/EG
 EMV-Richtlinie2014/30/EU
 RoHS-Richtlinie2011/65/EU
Angewandte Normen:EN 60947-5-3:2013
EN ISO 13849-1:2015
EN 61508 Teile 1-7:2010
Benannte Stelle der Baumusterprüfung:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
Kenn-Nr.: 0035
Baumusterprüfbescheinigung:01/205/5194.02/20
Bevollmächtigter für die Zusammenstellung der technischen Unterlagen:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Ort und Datum der Ausstellung:Wuppertal, 9. Juni 2023
 GRA_SIG_ksig-y24
 Rechtsverbindliche Unterschrift
Philip Schmersal
Geschäftsführer
UK Declaration of Conformity LOG_COM_lo1de01s
Company:K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom.
Name of the component:CSS 34
Type:See ordering code
Description of the component:Non-contact safety sensor
Relevant legislation:Supply of Machinery (Safety) Regulations2008
 Electromagnetic Compatibility Regulations2016
 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations2012
Designated standards:EN 60947-5-3:2013
EN ISO 13849-1:2015
EN 61508 parts 1-7:2010
Approved body for Type Examination:TÜV Rheinland UK Ltd.
1011 Stratford Road
Solihull, B90 4BN
ID: 2571
Type examination certificate:01/205U/5194.00/22
UK-Importer /
Person authorised for the compilation of the technical documentation:



Schmersal UK Ltd.
Paul Kenney
Unit 1, Sparrowhawk Close
Enigma Business Park
Malvern, Worcestershire, WR14 1GL
Place and date of issue:Wuppertal, June 9, 2023
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.

Generiert am: 26.12.2024, 03:06