schmersal_s_icon.png

BN 325-R-1279 5,0M

Número de artículo: 101147097

Descargas

Trace Parts Datos CAD
ePLAN Datos
CADENAS Datos CAD
SISTEMA Datos
Product type description:
BN 325-R(1)-(2)

(1)
 without LED
Gwith LED

(2)
 Blade terminal 4,8 mm and 1 shielding plate
1239Blade terminal 4,8 mm and 2 shielding plate
1389Blade terminal 6,3 mm and 2 shielding plates
1279 ..MCable (Length in m) on the left side and 2 shielding plates
1279-2 ..MCable (Length in m) on the right side and 2 shielding plates
LST-1279 ..MCable with connector M12 on the left side, Length in m
LST-1279-2 ..MCable with connector M12 on the right side, Length in m
No todos los equipos posibles según este código de pedidos están disponibles y/o son realizables técnicamente.
  • Cable output left and 2 shielding plates
  • Actuation from front
  • Non-contact principle
  • 1 Reed contakts
  • Long life
  • Actuating surface and direction of actuation marked by switch symbol
  • 85 mm x 26 mm x 24 mm
  • Thermoplastic enclosure

Ordering data

Product type description

BN 325-R-1279 5,0M

Article number (order number)

101147097

EAN (European Article Number)

4030661141350

eCl@ss number, version 12.0

27-27-43-02

eCl@ss number, version 11.0

27-27-01-05

eCl@ss number, version 9.0

27-27-01-05

ETIM number, version 7.0

EC002544

ETIM number, version 6.0

EC002544

General data

Working principle

magnético

Housing construction form

Rectangular

Housing material

Plástico reforzado con fibra de vidrio

Gross weight

280 g

Note

Integrated shielding plate (top and bottom)

General data - Features

Latching

Suitable for elevators

Cable sleeve

Number of snap-in contacts

1

Mechanical data

Active area

desde el lado frontal

Actuating element

Imán

Mechanical lifetime, minimum

1.000.000.000 Operations

Actuation direction

Lengthwise

Actuating speed, maximum

18 m/s

Mounting

trasero con 2 pernos roscados

Mechanical data - Switching distances

Switching distance Sn

5 mm … 55 mm

2 x BP 21S = 20 ... 55 mm

BP 34S = 10 ... 25 mm

BP 10N = 10 mm

BP 10S = 10 mm

2 x BP 10N = 15 mm

2 x BP 10S = 15 mm

BP 15N = 12 mm

BP 15S = 12 mm

2 x BP 15/2N = 17 mm

2 x BP 15/2S = 17 mm

BP 34N = 10 ... 25mm

BP 20N = 5 ... 20 mm

BP 20S = 5 ... 20 mm

BP 31N = 5 ... 20 mm

BP 31S = 5 ... 20 mm

BP 11N = 10 mm

BP 11S = 10 mm

2 x BP 11N = 20 mm

2 x BP 11S = 20 mm

BP 12N = 15 mm

BP 12S = 15 mm

2 x BP 12N = 10 ... 25 mm

2 x BP 12S = 10 ... 25 mm

BP 21N = 15 ... 40 mm

BP 21S = 15 ... 40 mm

2 x BP 21N = 20 ... 55 mm

Note (Switching distance Sn)

Distancia de accionamiento hasta 55 mm, dependiendo del imán de accionamiento y versión

Note (switching distance)

All switching distances in accordance EN IEC 60947-5-2

Repeat accuracy R

0,3 mm

Mechanical data - Connection technique

Length of cable

5 m

Cable entry

back, right

Termination

Cable de salida

Number of cable wires

2

Wire cross-section

0,75 mm2

Wire cross-section

18 AWG

Material of the Cable mantle

PVC

Cable type

H03VV-F

Mechanical data - Dimensions

Length of sensor

24 mm

Width of sensor

85 mm

Height of sensor

26 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature

-25 ... +70 °C

Resistance to vibrations

10…55 Hz, amplitud 1 mm

Restistance to shock

50 g / 11 ms

Resistant to vibration

30 g, de oscilación sinusoidal

Electrical data

Switching voltage, maximum

250 VAC

Switching current, maximum

3 A

Switching capacity, maximum

120 VA

Switching principle

Descansando

Bounce duration, minimum

0,3 ms

Bounce duration, maximum

0,6 ms

Switching frequency, maximum

300 Hz

Maximale Schalthäufigkeit

1.080.000 /h

Maximum switching time close (NO)

1,5 ms

Maximum switching time open (NC)

0,5 ms

Scope of delivery

Scope of delivery

Actuator must be ordered separately.

Accessory

Recommendation (actuator)

BP 10 S

2x BP 10 S

BP 15 S

BP 34 S

BP 20 S

BP 31 S

BP 11 S

2x BP 11 S

BP 12 S

BP 21 S

2x BP 21 S

BP 10 N

2x BP 10 N

BP 15 N

2 x BP 15/2 N

2x BP 15/2 S

BP 34 N

BP 20 N

BP 31 N

Recommendation (actuator, lift switchgear)

BP 10

2 x BP 15/2

2 x BP 10

BP 15

BP 34

Note

Note (General)

Otwarcie i zamknięcie zestyków zależy od kierunku aktywacji oraz typu i polaryzacji użytego magnesu aktywującego.

Filtro de idiomas

Descargar la versión actual de Adobe Reader

Diagrama de recorridos de contacto

Diagrama de recorridos de contacto

Diagrama


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Los datos e información anteriores se han verificado cuidadosamente. Las imágenes pueden diferir del original. Se pueden encontrar más datos técnicos en los manuales de instrucciones. Sujeto a cambios técnicos y errores.