SRB301LC/8
SRB301LC/8
Downloads
- Suitable for the signal processing of outputs with contact sensors
- 3 safety contacts, STOP 0, 1 Auxiliary contact
Ordering data
Note (Delivery capacity) |
Ei saatavana! |
Product type description |
SRB301LC/8 |
Article number (order number) |
101197553 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
Muovi, lasikuituvahvistettu kestomuovi, tuuletettu |
Gross weight |
250 g |
General data - Features
Electronic Fuse |
Kyllä |
Wire breakage detection |
Kyllä |
Cross-circuit detection |
Kyllä |
Start input |
Kyllä |
Feedback circuit |
Kyllä |
Automatic reset function |
Kyllä |
Earth connection detection |
Kyllä |
Integral system diagnostics, status |
Kyllä |
Number of auxiliary contacts |
1 |
Number of LEDs |
4 |
Number of normally closed (NC) |
2 |
Number of safety contacts |
3 |
Safety classification |
Vorschriften |
EN IEC 60947-5-1 EN IEC 61508 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
e |
Category, Stop 0 |
4 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
PFH value, Stop 0 |
2,00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Mechanical data
Mechanical life, minimum |
10 000 000 Operations |
Mounting |
Pikakiinnitys DIN-kiskoon standardin DIN EN 60715 mukaan |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
Jäykkä tai taipuisa Ruuviliitäntä M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
22,5 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +45 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10...55 Hz, Amplitudi 0,35 mm, ± 15 % |
Restistance to shock |
10 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
II |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VAC -15 % / +10 % |
Ripple voltage |
10 % |
Rated operating voltage |
24 VAC |
Rated operating voltage |
24 VDC |
Rated AC voltage for controls, 50 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
6 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
6 A |
Electrical power consumption |
2 W |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
uutena |
Drop-out delay in case of power failure, typically |
30 ms |
Drop-out delay in case of "emergency stop", maximum |
30 ms |
Pull-in delay at automatic start, maximum, typically |
110 ms |
Pull-in delay at RESET, typically |
20 ms |
Material of the contacts, electrical |
AgSn0. itsepuhdistuva, pakkotoiminto |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
EMC-Directive |
Status indication
Indicated operating states |
Releiden K2 tila Releiden K1 tila Sisäinen käyttöjännite Ui |
Other data
Note (applications) |
Turvatunnistin suojus Hätäpysäytyspainikkeet Köysihätäpysäyttimet Turvavaloverho |
Note
Note (General) |
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
Wiring example
Note (Wiring diagram) |
Kytkentäkaavion kytkennät on kuvattu suojukset suljettuna ja jännitteettömässä tilassa. Relelähdöt: 2-kanavainen ohjaus kontaktorien tai releiden pakkotoimisten koskettimien kautta mahdollistaa koskettimien kapasiteetin tai lukumäärän lisäämiseen . Automaattinen resetointi: automaattinen resetointi ohjelmoidaan yhdistämällä takaisinkytkentäpiiri päätteisiin X1/X2. Jos takaisinkytkentäpiiriä ei tarvita,liittimet oikosuljetaan keskenään. Ohjain tunnistaa valvontapiirissä olevan oikosulun, johdinkatkon ja maasulun. Tulotaso: Esimerkissä näkyy turvaoven kaksikanavainen valvonta, jossa kaksi rajakytkintä, joista toinen pakkoavauksella, ulkoisella kuittauspainikkeella (R); ristiinjohdotuksen valvonta ja takaisinkytkentäpiiri (H2). Käytettäessä 1-kanavaista valvontaa kytke NC-kosketin käyttöjännitteeseen ja siltaa S11/S12 ja S21/S22. |
Kielisuodatin
Tuotelehti
Käyttöohjeet ja vaatimuksenmukaisuusvakuutus
Lattaa Adobe Readerin viimeisin versio
Tuotekuva( luettelokuva)
Kytkentäesimerkki
Merkki (tekninen standardi)
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Tiedot ja arvot on tarkastettu huolellisesti. Kuvat voivat poiketa alkuperäisestä. Tarkemmat tekniset tiedot löytyvät manuaalista. Pidätämme oikeuden teknisiin muutoksiin ja virheisiin.
Luotu: 5.4.2025 15.03