schmersal_s_icon.png

TZFCWN24VDC-2917

Numéro d'article: 137000295

Téléchargements

TraceParts Données
ePLAN Données
CADENAS Données CAO
SISTEMA Données
Product type description:
TZ(1)(2)(3)(4)(5)24VCD-(6)

(1)
MPower to lock
FPower to unlock

(2)
 Contact variants (also refer to 4.3)
 Magnet: 1 NC contact; actuator: 1 NC contact / 1 NO contact
WMagnet: 1 NC contact; actuator: 1 NC contact / 1 NO contact
CMagnet: 1 NC contact/1 NO contact; actuator: 1 NC contact / 1 NO contact
CWMagnet: 1 NC contact/1 NO contact; actuator: 1 NC contact / 1 NO contact
3OE/1SMagnet: 1 NC contact; actuator: 2 NC contacts / 1 NO contact
W3OEMagnet: 1 NC contact; actuator: 2 NC contacts / 1 NO contact
4OEMagnet: 2 NC contacts; actuator: 2 NC contacts
W2MOEMagnet: 2 NC contacts; actuator: 1 NC contact/1 NO contact

(3)
NEmergency release N
.NEAncillary release .NE
.NEMAncillary release .NEM
SManual release using triangular key
SPManual release with triangular key and release bar
S.NFEmergency exit and manual release

(4)
Lwith LED display

(5)
.CHIActuating head higher and rotated 180°

(6)
3053Customer-specific contact variant
Il est possible que certains appareils suivant cet exemple de commande ne soient pas livrables et/ou techniquement réalisables.
  • Thermoplastic enclosure
  • Holding force 1500 N

Ordering data

Product type description

TZFCWN24VDC-2917

Article number (order number)

137000295

EAN (European Article Number)

8905236100055

eCl@ss number, version 12.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 9.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

cULus

CCC

General data

Standards

BG-GS-ET-19

EN IEC 60947-5-1

Coding level according to EN ISO 14119

faible

Working principle

électromécanique

Housing material

Plastique, thermoplastique renforcé de fibres de verre

General data - Features

Power to unlock

Oui

Number of actuating directions

4

Safety classification

Standards

EN ISO 13849-1

Performance Level, up to

c

Category

1

B10D Normally-closed contact (NC)

2.000.000 Operations

Note

Electrical life on request.

B10D Normally-open contact (NO)

1.000.000 Operations

Note

at 10% Ie and ohmic load

Mission time

20 Year(s)

Safety classification - Fault exclusion

Please note:

Utilisable si l'exclusion d'une défaillance dangereuse de la mécanique à 1 canal est autorisée et si une protection antifraude suffisante est garantie.

Performance Level, up to

d

Category

3

Note

for 2-channel use and with suitable logic unit.

Mission time

20 Year(s)

Mechanical data

Mechanical lifetime, minimum

1.000.000 Operations

Holding force FZh in accordance with EN ISO 14119

1.500 N

Latching force

20 N

Positive break travel

3,5 mm

Positive break force per NC contact, minimum

20 N

Positive break force, minimum

20 N

Actuating speed, maximum

0,3 m/s

Mounting

Vis

Type of the fixing screws

3x M6

Tightening torque of the fastening screws for the housing cover, minimum

0,8 Nm

Tightening torque of the fastening screws for the housing cover, maximum

0,8 Nm

Mechanical data - Connection technique

Termination

Bornes à vis

Cable section, minimum

1 x 0,5 mm²

Cable section, maximum

1 x 1,5 mm²

Note

Toutes les indications relatives à la section du câble sont embouts compris.

Mechanical data - Dimensions

Length of sensor

41 mm

Width of sensor

129 mm

Height of sensor

92,5 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature

+0 ... +50 °C

Note (Relative humidity)

sans condensation

non givrant

Ambient conditions - Insulation values

Rated insulation voltage Ui

250 VAC

Rated impulse withstand voltage Uimp

2,5 kV

Electrical data

Thermal test current

4 A

Required rated short-circuit current

1.000 A

Electrical power consumption, maximum

8,5 W

Switching principle

contacts à action dépendante

Maximale Schalthäufigkeit

1.200 /h

Material of the contacts, electrical

Argent

Electrical data - Magnet control

Magnet switch-on time

100 %

Test pulse duration, maximum

5 ms

Test pulse interval, minimum

50 ms

Electrical data - Safety contacts

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

4 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

4 A

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

4 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

4 A

Other data

Note (applications)

protecteur coulissant

protecteur amovible

protecteur pivotant

Scope of delivery

Scope of delivery

Actuator must be ordered separately.

Filtre de langue

Télécharger la dernière version d'Adobe Reader


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.