AZ 16-12ZI-B6R-M20
AZ 16-12ZI-B6R-M20
Désignation produit: AZ 16-(1)ZI-(2)-(3) |
(1) | |
03 | 3 contacts NF |
12 | 1 contact NO / 2 contacts NF |
(2) | |
B1 | modèle droit |
B1-1747 | modèle droit avec loqueteau magnétique |
B1-2024 | modèle droit avec obturateur d' entrée |
B1-2053 | modèle droit avec loqueteau à bille |
B1-2177 | modèle droit avec guide d'entrée |
B6L | coudé, mobile vers la gauche |
B6R | coudé, mobile vers la droite |
(3) | |
M16 | Entrée de câble M 16 |
M20 | Entrée de câble M 20 |
- 3 cable entries M 16 x 1.5
- Thermoplastic enclosure
- Individual coding
- Coding level "High" according to ISO 14119
- 52 mm x 90 mm x 30 mm
- Long life
- Double-insulated
- Large wiring compartment
- High level of contact reliability with low voltages and currents
- Insensitive to soiling
- Slotted holes for adjustment, circular holes for location
Ordering data
Product type description |
AZ 16-12ZI-B6R-M20 |
Article number (order number) |
103010579 |
EAN (European Article Number) |
4030661473109 |
eCl@ss number, version 12.0 |
27-27-26-02 |
eCl@ss number, version 11.0 |
27-27-26-02 |
eCl@ss number, version 9.0 |
27-27-26-02 |
ETIM number, version 7.0 |
EC002592 |
ETIM number, version 6.0 |
EC002592 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 |
Coding level according to EN ISO 14119 |
haut |
Housing material |
Plastique, thermoplastique renforcé de fibres de verre, auto-extinguible |
Material of the actuator |
Acier inoxydable |
Gross weight |
200 g |
General data - Features
Ejection force |
Oui |
Number of auxiliary contacts |
1 |
Number of safety contacts |
2 |
Safety classification |
Vorschriften |
EN ISO 13849-1 |
Performance Level, up to |
c |
Category |
1 |
B10D Normally-closed contact (NC) |
2 000 000 Operations |
Note |
Electrical life on request. |
B10D Normally-open contact (NO) |
1 000 000 Operations |
Note |
at 10% Ie and ohmic load |
Mission time |
20 Year(s) |
Safety classification - Fault exclusion |
Please note: |
Utilisable si l'exclusion d'une défaillance dangereuse de la mécanique à 1 canal est autorisée et si une protection antifraude suffisante est garantie. |
Performance Level, up to |
d |
Category |
3 |
Note |
for 2-channel use and with suitable logic unit. |
Mission time |
20 Year(s) |
Mechanical data
Actuating radius, minimum |
35 mm |
Actuator |
angulaire mobile |
Mechanical life, minimum |
1 000 000 Operations |
Positive break travel |
8 mm |
Positive break force per NC contact, minimum |
10 N |
Actuating speed, maximum |
2 m/s |
Mounting |
Vis |
Type of the fixing screws |
2x M6 |
Mechanical data - Connection technique
Cable entry |
3 x M20 x 1,5 |
Termination |
Bornes à vis |
Cable section, minimum |
0,75 mm² |
Cable section, maximum |
2,5 mm² |
Note |
Toutes les indications relatives à la section du câble sont embouts compris. |
Mechanical data - Dimensions
Length of sensor |
30 mm |
Width of sensor |
52 mm |
Height of sensor |
90 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-30 ... +80 °C |
Storage and transport temperature |
-40 ... +85 °C |
Permissible installation altitude above sea level, maximum |
2 000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
500 V |
Rated impulse withstand voltage Uimp |
6 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Thermal test current |
10 A |
Required rated short-circuit current |
1 000 A |
Switching element |
1 contact NO, 2 contacts NF |
Switching principle |
slow action, positive break NC contact |
Maximale Schalthäufigkeit |
4 000 /h |
Material of the contacts, electrical |
Argent |
Electrical data - Safety contacts
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
4 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
4 A |
Electrical data - Auxiliary contacts
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
4 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
4 A |
Scope of delivery
Scope of delivery |
Actionneur à codage individuel B6, version droite: actionneur à codage individuel B6 version droite |
Note
Note (General) |
L'axe de rotation de la charnière doit être 5 mm plus haut que la face supérieure de l'interrupteur de sécurité Rayon d'actionnement min. pour dispositifs de protection pivotants 35 mm L'actionneur ne peut pas être livré séparément. |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Certificat UL
Bibliothèque/Library SISTEMA-VDMA
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Plan d'encombrement composant de base
Plan d'encombrement actionneur
Plan d'encombrement actionneur
Diagramme des contacts
Diagramme de contact
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 04/04/2025 01:41