EX-RS655-Z22-DS-2D
EX-RS655-Z22-DS-2D
- Ex-Zone 21 and 22
- Metal enclosure
- wire pull and breakage detection
- Protection class IP66, IP67
- Central connection terminal
- Mechanical switching position indication
- two-side operation / wire up to 2 x 100 m
Ordering data
Product type description |
EX-RS655-Z22-DS-2D |
Article number (order number) |
153038066 |
EAN (European Article Number) |
4030661546643 |
eCl@ss number, version 12.0 |
27-27-26-01 |
eCl@ss number, version 11.0 |
27-27-26-01 |
eCl@ss number, version 9.0 |
27-27-26-01 |
ETIM number, version 7.0 |
EC000030 |
ETIM number, version 6.0 |
EC000030 |
Approvals - Standards
Certificates |
ATEX IECEx NEPSI CCC-EX |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN 60079-31 |
Explosion protection zones |
21 |
Explosion protection category |
2D |
Explosion protection designation |
D II 2D Ex tb IIIC T80°C Db |
Manufacturer declaration, zone |
1 21 |
General data
Standards |
EN 620 EN ISO 13850 EN IEC 60947-5-1 EN IEC 60947-5-5 |
Housing material |
fonte grise, laquée |
Material of the housing cover |
fonte grise, laquée |
Length of the wire, maximum |
100 m |
Gross weight |
5 072 g |
General data - Features
Number of auxiliary contacts |
2 |
Number of safety contacts |
2 |
Feature |
two-side operation wire up to 2 x 100 m long |
Safety classification |
Vorschriften |
EN ISO 13849-1 |
Mission time |
20 Year(s) |
Safety classification - Safety outputs
B10D Normally-closed contact (NC) |
100 000 Operations |
Mechanical data
Actuating element |
Tête rotative à levier à galet N300 |
Mechanical life, minimum |
100 000 Operations |
Actuation direction |
Rotation à droite et à gauche par chaque fois 75° |
Mechanical data - Connection technique
Cable entry |
2 x M25 x 1,5 |
Termination |
Raccordement par bornes à ressort |
Cable section, minimum |
0,5 mm², flexible |
Cable section, maximum |
2,5 mm², flexible |
Ambient conditions
Degree of protection |
IP66 IP67 |
Ambient temperature |
-40 ... +70 °C |
Protection class |
I |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
300 V |
Rated impulse withstand voltage Uimp |
4 kV |
Degree of pollution |
3 |
Electrical data
Thermal test current |
6 A |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
3 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
3 A |
Switching principle |
Rupture brusque |
Material of the contacts, electrical |
Argent |
Other data
Note (applications) |
Interrupteurs de sécurité à commande par câble |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
IECEx certification
Certificat NEPSI
Certification CCC
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Plan d'encombrement composant de base
Plan d'encombrement composant de base
Plan d'encombrement composant de base
Exemple d'assemblage
EU Declaration of Conformity | ![]() |
Original | SCHMERSAL Industrial Switchgear (Shanghai) Co., Ltd. Cao Ying Road 3336 201712 Shanghai / Qingpu P.R. CHINA Internet: www.schmersal.com.cn |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | Marking: |
EX-I-RS6551) | D II 2G Ex ia IIC T6 Gb |
D II 2D Ex ia IIIC T85°C Db | |
D II 2D Ex tb IIIC T85°C Db | |
EX-RS6552) | D II 2G Ex db eb IIC T6 Gb |
D II 2D Ex tb IIIC T85°C Db | |
D II 2G Ex ia IIC T6 Gb | |
D II 2D Ex ia IIIC T85°C Db | |
EX-RS655-…-DS-2D3), EX-RS655-…-DN-2D3) | D II 2D Ex tb IIIC T85°C Db |
Type: | See ordering code |
Description of the component: | Pull-wire emergency stop switch for safety function or pull-wire emergency stop switch 3) optionally with Dupline® or DuplineSafe® input module |
Relevant Directives: | Machinery Directive | 2006/42/EC |
Explosion Protection Directive (ATEX) | 2014/34/EU | |
3) EMC Directive | 2014/30/EU | |
RoHS Directive | 2011/65/EU |
Applied standards: | EN 60947-5-1:2017 + AC:2020, EN 60947-5-5:1997 + A1:2005 + A11:2013 + A2:2017, EN ISO 13850:2015, EN ISO 13849-1:2015 1) EN IEC 60079-0:2018, EN 60079-11:2012, EN 60079-31:2014 2) EN IEC 60079-0:2018, EN 60079-1:2014, EN IEC 60079-7:2015 + A1:2018, EN 60079-11:2012, EN 60079-31:2014 3) EN IEC 60079-0:2018, EN 60079-31:2014 |
Notified body, which approved the full quality assurance system, referred to Appendix IV, 2014/34/EU and for the ATEX certification: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
EU-Type Examination Certificate: | TÜV 19 ATEX 8428 |
This certificate refers only to the certification of the products in accordance with the Explosion Protection Directive 2014/34/EU (ATEX). Product conformity in accordance with the Machinery Directive 2006/42/EC is declared by the manufacturer under its own responsibility. |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Shanghai, June 28, 2023 |
![]() |
Authorised signature Michele Seassaro Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 08/04/2025 00:01