SRB211ST (V2)
SRB211ST (V2)
- 2 safety contacts, STOP 0; 1 safety contact, STOP 1
- 1 Signalling output
- Suitable for the signal processing of outputs with contact sensors
- Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
Ordering data
Product type description |
SRB211ST (V2) |
Article number (order number) |
101208309 |
EAN (European Article Number) |
4030661448923 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Notice |
Produit de fin de série |
Approvals - Standards
Certificates |
IFA cULus CCC TILVA |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
Plastique, thermoplastique renforcée de fibres de verre, ventilée |
Gross weight |
280 g |
General data - Features
Electronic Fuse |
Oui |
Wire breakage detection |
Oui |
Cross-circuit detection |
Oui |
Removable Terminals |
Oui |
Start input |
Oui |
Feedback circuit |
Oui |
Automatic reset function |
Oui |
Reset edge detection |
Oui |
Earth connection detection |
Oui |
Integral system diagnostics, status |
Oui |
Number of LEDs |
6 |
Number of normally closed (NC) |
2 |
Number of safety contacts |
3 |
Number of Safety contacts, STOP 0 |
3 |
Number of Safety contacts, STOP 1 |
2 |
Number of signalling outputs |
1 |
Safety classification |
Vorschriften |
EN IEC 60947-5-1 EN IEC 61508 |
Stop-Category |
0 1 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
e |
Performance Level, stop 1, up to |
d |
Category, Stop 0 |
4 |
Category, Stop 1 |
3 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
Diagnostic Coverage (DC) Level, Stop 1 |
> 60 |
PFH value, Stop 0 |
2,00 x 10⁻⁸ /h |
PFH value, Stop 1 |
2,00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Safety Integrity Level (SIL), Stop 1, suitable for applications in |
2 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
PFD value |
5,30 x 10⁻⁵ |
PFD value |
5,30 x 10⁻⁵ |
Mechanical data
Mechanical life, minimum |
10 000 000 Operations |
Mounting |
Fixation rapide sur rails DIN standards selon DIN EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
rigide ou flexible Raccord fileté M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
22,5 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +60 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10...55 Hz, amplitude 0,35 mm, ± 15 % |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VAC -15 % / +10 % |
Ripple voltage |
10 % |
Rated operating voltage |
24 VAC |
Rated operating voltage |
24 VDC |
Rated AC voltage for controls, 50 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Electrical power consumption |
2,4 W |
Electrical power consumption |
5,9 VA |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
à l'état neuf |
Drop-out delay in case of power failure, typically |
80 ms |
Drop-out delay in case of emergency, typically |
30 ms |
Pull-in delay at automatic start, maximum, typically |
250 ms |
Pull-in delay at RESET, typically |
20 ms |
Material of the contacts, electrical |
AgSn0, Ag-Ni, autonettoyant, à guidage forcé |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
6 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
6 A |
Switching capacity, minimum |
10 VDC |
Switching capacity, minimum |
10 mA |
Switching capacity, maximum |
250 VAC |
Switching capacity, maximum |
8 A |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
3 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
2 A |
Switching capacity, minimum |
10 VDC |
Switching capacity, minimum |
10 mA |
Switching capacity, maximum |
250 VAC |
Switching capacity, maximum |
6 A |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Digital Output
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,1 A |
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum |
24 VDC |
Switching capacity, maximum |
2 A |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
Directive CEM |
Status indication
Indicated operating states |
Position relais K2 Position relais K1 Tension de service interne Ui Position relais K3/4 |
Other data
Note (applications) |
Capteur de sécurité Dispositif de protection Bouton d'arrêt d'urgence Interrupteurs de sécurité à commande par câble Rideau lumineux de sécurité |
Note
Note (General) |
Des charges inductives (p.ex. relais externe, etc.) doivent être antiparasitées par un dispositif approprié. |
Wiring example
Note (Wiring diagram) |
L'exemple de câblage est représenté pour les protecteurs fermés et hors tension. Démarrage automatique: le démarrage automatique est configuré par le raccordement de la boucle de retour aux bornes X1/X3. Si la boucle de retour n'est pas utilisée, établir un pont. Niveau d'entrée: l'exemple reprend une commande à 2 canaux d'une surveillance de protecteur avec deux interrupteurs de position, dont un avec ouverture forcée, un bouton de réarmement externe (R) et une boucle de retour (H2). La commande détecte les courts-circuits transversaux, les ruptures de câbles et les fuites à la terre dans le circuit de surveillance. Pour une commande à 1 canal, raccorder le contact NF à S11/S12 et ponter S12/S22 Raccorder les sorties statiques à commutation p avec potentiel des rideaux lumineux/barrières immatérielles de sécurité à S12/S22. Les dispositifs doivent avoir le même potentiel de référence. La sortie de sécurité 37/38 correspond à la catégorie d'arrêt 1 selon EN 60204-1, les contacts de sécurité 13/14 et 23/24 correspondent à la catégorie d'arrêt 0 selon EN 60204-1. F1 = fusible hybride |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Certificat UL
Certificat TILVA
Certification CCC
Certificat CE avec examen de type
Exemple de câblage (câblage électrique)
Bibliothèque/Library SISTEMA-VDMA
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Exemple de câblage
Symbole (norme technique)
103007222 SRB-E-212ST
- Plug-in screw terminals with coding
- STOP 0 / 1 Function
- 1 oder 2-channel control
- 2 safety contacts STOP 0
- 1 Safety output STOP 1
- Drop-out delay 0 … 30
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | SRB211ST-24V V.2 SRB211ST/PC-24V V.2 SRB211ST/CC-24V V.2 |
Description of the component: | Safety relay module for emergency stop circuits, guard door monitoring, magnetic safety switches and AOPD's |
Relevant Directives: | Machinery Directive | 2006/42/EC |
EMC-Directive | 2014/30/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | DIN EN 60947-5-1:2018 DIN EN ISO 13849-1:2023 |
Notified body for Type Examination: | DGUV Test Prüf- und Zertifizierungsstelle Elektrotechnik Gustav-Heinemann-Ufer 130 50968 Köln ID n°: 0340 |
EC-Type Examination Certificate: | ET 24017 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, September 27, 2024 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 01/05/2025 15:21