SSB-R-NG-1-O-S-V01
SSB-R-NG-1-O-S-V01
- Magnetic track sensor box
- 4 tracks, 2 optional for fine positioning
- optional fine positioning tracks with prewarning indication
- Maintenance-free signal storage and switching in case of power failure
- Wide angle LED track display
Ordering data
Product type description |
SSB-R-NG-1-O-S-V01 |
Article number (order number) |
103038393 |
EAN (European Article Number) |
4030661566160 |
eCl@ss number, version 12.0 |
27-27-43-02 |
eCl@ss number, version 11.0 |
27-27-01-05 |
eCl@ss number, version 9.0 |
27-27-01-05 |
ETIM number, version 7.0 |
EC002544 |
ETIM number, version 6.0 |
EC002544 |
Approvals - Standards
Certificates |
cULus |
General data
Working principle |
magnétique |
Housing material |
Plastique, renforcé de fibres de verre |
Material of the housing cover |
Polycarbonate |
Gross weight |
314 g |
General data - Features
Latching |
Oui |
Suitable for elevators |
Oui |
Number of LEDs |
5 |
Number of snap-in contacts |
4 |
Number of signalling outputs |
4 |
Mechanical data
Actuating panels |
côté avant |
Actuating element |
Aimant |
Mechanical life, minimum |
1 000 000 000 Operations |
Minimum distance devices |
50 mm |
Actuation direction |
On when driving over with north magnet in driving direction |
Actuating speed, maximum |
9 m/s |
Mounting |
à l'arrière avec 2 boulons filetés |
Type of the fixing screws |
2x M4 |
Tightening torque of the fixing screws, minimum |
2 Nm |
Tightening torque of the fixing screws, maximum |
4 Nm |
Mechanical data - Switching distances
Switching distance Smin, minimum |
2 mm |
Switching distance Smax, maximum |
15 mm |
Note (switching distance) |
Empfohlen 7mm |
Repeat accuracy R |
0,5 mm |
Mechanical data - Connection technique
Terminal (mechanical) |
Connecteur: M12, 8 pôles, codage A |
Mechanical data - connector side A
Connector typ |
Male connector, M12 |
Connector coding |
A |
Connector latching |
Fermeture vissée |
Number of pol, side A |
8 |
Mechanical data - Dimensions
Length of sensor |
125 mm |
Width of sensor |
110 mm |
Height of sensor |
24,4 mm |
Ambient conditions
Degree of protection |
IP54 IP65 |
Ambient temperature |
-25 ... +70 °C |
Storage and transport temperature |
-40 ... +85 °C |
Relative humidity, maximum |
95 % |
Note (Relative humidity) |
sans condensation non givrant |
Resistance to vibrations |
10…55 Hz, amplitude 1 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
III |
Permissible installation altitude above sea level, maximum |
2 000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
1 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC +15 % / +10 % |
Current consumption at 24V, minimum |
11 mA |
No-load supply current I0, typical |
20 mA |
Rated operating voltage |
24 VDC |
Operating current |
1 500 mA |
Utilisation category DC-12 |
24 VDC |
Utilisation category DC-12 |
0,3 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
0,3 A |
Switching capacity, maximum |
7,2 W |
Switching element |
contact bistable |
Switching principle |
Contacts Reed, fonctionnant sans contact |
Bounce duration, maximum |
0,3 ms |
Maximum switching time close |
1 ms |
Maximum switching time open |
0,1 ms |
Electrical fuse rating, maximum |
2 A |
Electrical data - Digital Output
Output current, maximum |
300 mA |
Design of control elements |
Contacts Reed |
Accessory
Recommendation (actuator) |
BP 15 BP 15/2 |
Recommendation (actuator, lift switchgear) |
BP 15 |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Certificat UL
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Plan d'encombrement composant de base
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 04/04/2025 06:40