EX-TR 355-12Z-3G/D
EX-TR 355-12Z-3G/D
- Metal enclosure
- Good resistance to oil and petroleum spirit
- 66,7 mm x 76 mm x 38 mm
- Actuator heads can be repositioned by 4 x 90°
- Including Ex-certified screwed cable gland and screw plug
- Mounting details to EN 50041
- 3 cable entries M 20 x 1.5
Exemple de commande
Product type description |
EX-TR 355-12Z-3G/D |
Article number (order number) |
101205164 |
EAN (European Article Number) |
4030661370798 |
Homologations - Règlementations
Certificates |
cULus ATEX (Konformitätserklärung) |
Protection antidéflagrante
Explosion protection: regulations |
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31 |
Explosion protection zones |
2 22 |
Explosion protection category |
3G 3D |
Explosion protection designation |
D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X |
Manufacturer declaration |
ATEX Zone 2 et 22 |
Caractéristiques globales
Standards |
BG-GS-ET-15 EN IEC 60947-5-1 |
Housing construction form |
Construction normée |
Actuator type to EN 50041 |
C |
Housing material |
alliage léger,injecté |
Housing coating material |
laquée |
Gross weight |
295 g |
Données générales - Caractéristiques
Safety functions |
Oui |
Number of auxiliary contacts |
1 |
Number of safety contacts |
2 |
Classification
Standards |
EN ISO 13849-1 |
Mission time |
20 Year(s) |
Classification de sécurité - Sorties de sécurité
B10D Normally-closed contact (NC) |
20.000.000 Operations |
Données mécaniques
Actuating element |
poussoir à galet |
Mechanical lifetime, minimum |
30.000.000 Operations |
Impact energy, maximum |
1 J |
Actuating force, minimum |
17 N |
Actuating speed, maximum |
0,5 m/s |
Note (Actuating speed) |
Vitesse d'attaque pour un angle d'attaque vertical sur le poussoir de 30° |
Note (Switchover time) |
Temps de commutation selon la vitesse d'actionnement |
Données mécaniques – technique de connexion
Termination |
Raccord fileté M20 x 1.5 |
Cable cross-section of the cable glands, minimum |
7 mm |
Cable cross-section of the cable glands, maximum |
12 mm |
Cable section, minimum |
0,75 mm² |
Cable section, maximum |
2,5 mm² |
Note |
Toutes les indications relatives à la section du câble sont embouts compris. |
Wire cross-section |
13 AWG |
Données mécaniques - Dimensions
Length of sensor |
38 mm |
Width of sensor |
40,5 mm |
Height of sensor |
116,6 mm |
Conditions ambiantes
Degree of protection |
IP67 |
Ambient temperature |
-20 ... +60 °C |
Conditions ambiantes - Valeur d'isolation
Rated insulation voltage Ui |
250 VAC |
Rated impulse withstand voltage Uimp |
4 kV |
Données électriques
Thermal test current |
10 A |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
4 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
1 A |
Switching element |
Contact NO, contact NF |
Switching principle |
contacts à action dépendante |
Bounce duration, maximum |
2 ms |
Maximale Schalthäufigkeit |
5.000 /h |
Material of the contacts, electrical |
Argent |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Certificat UL
Bibliothèque/Library SISTEMA-VDMA
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Plan d'encombrement composant de base
Plan d'encombrement actionneur
Diagramme des contacts
Diagramme de contact
Principe de fonctionnement
151205164 EX-TR 355-12Z-3G/D
- Metal enclosure
- Good resistance to oil and petroleum spirit
- 66,7 mm x 76 mm x 38 mm
- Actuator heads can be repositioned by 4 x 90°
- Including Ex-certified screwed cable gland and screw plug
- Mounting details to EN 50041
- 3 cable entries M 20 x 1.5
Déclaration UE de conformité | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Déclaration: | Par la présente, nous certifions que les composants identifiés ci-après répondent de par leur conception et leur construction aux exigences des Directives Européennes applicables. |
Désignation du composant: | EX-Z/T 335-...-3G/D EX-Z/T 355-...-3G/D |
Type: | voir exemple de commande |
Marquage: | D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X |
Description du composant: | Interrupteur de position à manoeuvre positive d'ouverture pour fonctions de sécurité ou interrupteur de position sans fonction de sécurité |
Directives pertinentes: | Directive Machines (pour les composants de sécurité libellés "Safety component") | 2006/42/CE |
Directive ATEX Constructeur (Atmosphères Explosibles) | 2014/34/EU | |
Directive RoHS | 2011/65/EU |
Normes appliquées: | EN 60947-5-1:2017 + AC:2020 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 |
La conformité avec la directive ATEX 2014/34/EU est attestée par le fabricant sans l' intervention d' un organisme de certification de la conformité. |
Représentant autorisé à préparer et composer la documentation technique: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Lieu et date de l'émission: | Wuppertal, le 7 septembre 2023 |
![]() |
Signature à l'effet d'engager la société Philip Schmersal Président Directeur Général |
Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 2025-10-18 21 h 20