CSS 11-300-D-M-ST
CSS 11-300-D-M-ST
- Thermoplastic enclosure
- Max. 31 sensors can be wired in series.
- Connector M12, 8-pole
- Ø M30
- High repeat accuracy of the switching points
- Max. length of the sensor chain 200 m
- 2 short-circuit proof PNP safety outputs
- Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
- Safety sensor can also be installed behind V4A covers.
Ordering data
Note (Delivery capacity) |
Excluído do programa de fornecimento! |
Product type description |
CSS 11-300-D-M-ST |
Article number (order number) |
101213904 |
EAN (European Article Number) |
4030661405650 |
eCl@ss number, version 12.0 |
27-27-46-01 |
eCl@ss number, version 11.0 |
27-27-24-03 |
eCl@ss number, version 9.0 |
27-27-24-03 |
ETIM number, version 7.0 |
EC001829 |
ETIM number, version 6.0 |
EC001829 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN ISO 13849-1 EN IEC 60947-5-3 |
Working principle |
indutivo |
Housing construction form |
cilindro, rosca |
Installation conditions (mechanical) |
não nivelado |
Sensor topology |
Equipamento para acionamento em série |
Housing material |
Plástico |
Active area |
Plástico |
Reaction time, maximum |
60 ms |
Duration of risk, maximum |
60 ms |
Gross weight |
135 g |
General data - Features
Diagnostic output |
Sim |
Short circuit detection |
Sim |
Cross-circuit detection |
Sim |
Safety functions |
Sim |
Cascadable |
Sim |
Integral system diagnostics, status |
Sim |
Number of LEDs |
2 |
Number of semi-conductor outputs with signaling function |
1 |
Number of fail-safe digital outputs |
2 |
Number of series-wiring of sensors |
31 |
Safety classification |
Vorschriften |
EN IEC 60947-5-3 EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
3,60 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Mechanical data
Actuating panels |
Atuação pelo topo |
Active area |
Frontal |
Mechanical data - Switching distances
Switch distance, typical |
11 mm |
Assured switching distance "ON" Sao |
8 mm |
Assured switching distance "OFF" Sar |
15 mm |
Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-3 |
Hysteresis (Switching distance), maximum |
2 mm |
Repeat accuracy R |
1 mm |
Mechanical data - Connection technique
Note (length of the sensor chain) |
O comprimento e a secção do cabo alteram a queda de tensão em função da corrente de saída |
Mechanical data - Dimensions
ISO thread of the sensor |
M30 |
Length of sensor |
99,5 mm |
Ambient conditions
Degree of protection |
IP65 IP67 |
Ambient temperature |
-25 ... +65 °C |
Storage and transport temperature |
-25 ... +85 °C |
Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
II |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VAC/DC |
Rated impulse withstand voltage Uimp |
0,8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC -15 % / +10 % |
No-load supply current I0, typical |
100 mA |
Rated operating voltage |
24 VDC |
Operating current |
600 mA |
Required rated short-circuit current |
100 A |
Switching frequency, approx. |
3 Hz |
Utilisation category DC-12 |
24 VDC / 0,05 A |
Electrical data - Safety digital outputs
Rated operating current (safety outputs) |
250 mA |
Output current, (fail-safe output), maximum |
0,25 A |
Design of control elements |
tipo p |
Voltage drop Ud, maximum |
0,5 V |
Leakage current Ir, maximum |
0,5 mA |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,25 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,25 A |
Electrical data - Diagnostic outputs
Design of control elements |
comutação p |
Voltage drop Ud, maximum |
5 V |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,05 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,05 A |
Electrical data - Electromagnetic compatibility (EMC)
Interfering radiation |
IEC 61000-6-4 |
EMC rating |
IEC 61000-6-2 |
Pin assignment
PIN 1 |
1A1 Ue: (1) |
PIN 2 |
X1 entrada de segurança 1 |
PIN 3 |
A2 GND |
PIN 4 |
Y1 Saída de segurança 1 |
PIN 5 |
OUT Saída de diagnóstico |
PIN 6 |
X2 entrada de segurança 2 |
PIN 7 |
Y2 Saída de segurança 2 |
PIN 8 |
IN sem função |
Scope of delivery
Scope of delivery |
O atuador não está incluído no fornecimento. |
Scope of delivery of mounting material |
2x Acessórios de montagem porcas M30 |
Accessory
Recommendation (actuator) |
CST 30S-1 |
Recommended safety switchgear |
PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
Note
Note (General) |
Os requisitos para a avaliação: As pausas de desconexão de 250 μs -1500 μs devem ser toleradas pela avaliação. |
Filtro de idioma
Ficha técnica
Manual de instruções e Declaração de conformidade
Certificação UL
SISTEMA-VDMA Biblioteca/Library
Faça download da versão mais recente do Adobe Reader
Foto do produto (foto individual do catálogo )
Desenho dimensional componente básico
Curva de característica
Princípio operacional
Disposição dos contatos
101204612 CSS 11-30S-D-M-ST
- Stainless steel enclosure
- Max. 31 sensors can be wired in series.
- Connector M12, 8-pole
- Ø M30
- High repeat accuracy of the switching points
- Max. length of the sensor chain 200 m
- 2 short-circuit proof PNP safety outputs
- Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
- Safety sensor can also be installed behind V4A covers.
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Os dados e informações fornecidas foram cuidadosamente verificados. No entanto as imagens podem divergir do original. Informações técnicas adicionais podem ser encontradas no manual. Alterações técnicas e erros são possíveis.
Gerado em 04/07/2025 04:27