schmersal_s_icon.png

CSS 11-300-D-M-ST

Código do item: 101213904

Downloads

TraceParts Dados CAD
CADENAS CAD Dados
  • Thermoplastic enclosure
  • Max. 31 sensors can be wired in series.
  • Connector M12, 8-pole
  • Ø M30
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
  • Safety sensor can also be installed behind V4A covers.

Ordering data

Note (Delivery capacity)

Excluído do programa de fornecimento!

Product type description

CSS 11-300-D-M-ST

Article number (order number)

101213904

EAN (European Article Number)

4030661405650

eCl@ss number, version 12.0

27-27-46-01

eCl@ss number, version 11.0

27-27-24-03

eCl@ss number, version 9.0

27-27-24-03

ETIM number, version 7.0

EC001829

ETIM number, version 6.0

EC001829

Approvals - Standards

Certificates

cULus

General data

Standards

EN ISO 13849-1

EN IEC 60947-5-3

Working principle

indutivo

Housing construction form

cilindro, rosca

Installation conditions (mechanical)

não nivelado

Sensor topology

Equipamento para acionamento em série

Housing material

Plástico

Active area

Plástico

Reaction time, maximum

60 ms

Duration of risk, maximum

60 ms

Gross weight

135 g

General data - Features

Diagnostic output

Sim

Short circuit detection

Sim

Cross-circuit detection

Sim

Safety functions

Sim

Cascadable

Sim

Integral system diagnostics, status

Sim

Number of LEDs

2

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of series-wiring of sensors

31

Safety classification

Vorschriften

EN IEC 60947-5-3

EN IEC 61508

Performance Level, up to

e

Category

4

PFH value

3,60 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Actuating panels

Atuação pelo topo

Active area

Frontal

Mechanical data - Switching distances

Switch distance, typical

11 mm

Assured switching distance "ON" Sao

8 mm

Assured switching distance "OFF" Sar

15 mm

Note (switching distance)

All switching distances in accordance EN IEC 60947-5-3

Hysteresis (Switching distance), maximum

2 mm

Repeat accuracy R

1 mm

Mechanical data - Connection technique

Note (length of the sensor chain)

O comprimento e a secção do cabo alteram a queda de tensão em função da corrente de saída

Mechanical data - Dimensions

ISO thread of the sensor

M30

Length of sensor

99,5 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature

-25 ... +65 °C

Storage and transport temperature

-25 ... +85 °C

Resistance to vibrations

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VAC/DC

Rated impulse withstand voltage Uimp

0,8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 %

No-load supply current I0, typical

100 mA

Rated operating voltage

24 VDC

Operating current

600 mA

Required rated short-circuit current

100 A

Switching frequency, approx.

3 Hz

Utilisation category DC-12

24 VDC / 0,05 A

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0,25 A

Design of control elements

tipo p

Voltage drop Ud, maximum

0,5 V

Leakage current Ir, maximum

0,5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,25 A

Electrical data - Diagnostic outputs

Design of control elements

comutação p

Voltage drop Ud, maximum

5 V

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,05 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,05 A

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

EMC rating

IEC 61000-6-2

Pin assignment

PIN 1

1A1 Ue: (1)

PIN 2

X1 entrada de segurança 1

PIN 3

A2 GND

PIN 4

Y1 Saída de segurança 1

PIN 5

OUT Saída de diagnóstico

PIN 6

X2 entrada de segurança 2

PIN 7

Y2 Saída de segurança 2

PIN 8

IN sem função

Scope of delivery

Scope of delivery

O atuador não está incluído no fornecimento.

Scope of delivery of mounting material

2x Acessórios de montagem porcas M30

Accessory

Recommendation (actuator)

CST 30S-1

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Note

Note (General)

Os requisitos para a avaliação: As pausas de desconexão de 250 μs -1500 μs devem ser toleradas pela avaliação.
O tempo de desconexão do sensor de segurança de 250 μs aumenta adicionalmente conforme o comprimento e a capacitância do cabo utilizado. Com um cabo de ligação de 500 m atinge-se tipicamente um intervalo de desconexão de 500 μs.

101204612 CSS 11-30S-D-M-ST
  • Stainless steel enclosure
  • Max. 31 sensors can be wired in series.
  • Connector M12, 8-pole
  • Ø M30
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
  • Safety sensor can also be installed behind V4A covers.


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Os dados e informações fornecidas foram cuidadosamente verificados. No entanto as imagens podem divergir do original. Informações técnicas adicionais podem ser encontradas no manual. Alterações técnicas e erros são possíveis.

Gerado em 04/07/2025 04:27