MZM 120 B ST2-1P2PW2RE-A
MZM 120 B ST2-1P2PW2RE-A
Produkt-Typbezeichnung: MZM 120 (1)ST2-(2)RE-A |
(1) | |
B | Betätiger überwacht |
BM | Betätiger/Zuhaltung kombiniert überwacht |
(2) | |
1P2PW2 | 1 Diagnoseausgang und 2 Sicherheitsausgänge, p-schaltend und kombiniertes Diagnosesignal: Schutzeinrichtung geschlossen und Zuhaltung gesperrt |
SD2P | Serieller Diagnoseausgang und 2 Sicherheitsausgänge, p-schaltend |
- Actuator monitored
- connector plug M12, 8-pole
- Power to lock
- enabling signal, when safety
- Thermoplastic enclosure
- Safety switches must be used as end stop
- 40 mm x 179 mm x 40 mm
- Electronic contact-free, coded system
- Variably adjustable latching
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Intelligent diagnosis
- Self-monitoring series-wiring
Ordering data
Note (Delivery capacity) |
Nicht mehr lieferbar! |
Product type description |
MZM 120 B ST2-1P2PW2RE-A |
Article number (order number) |
101215714 |
EAN (European Article Number) |
4030661419312 |
eCl@ss number, version 12.0 |
27-27-26-03 |
eCl@ss number, version 11.0 |
27-27-26-03 |
eCl@ss number, version 9.0 |
27-27-26-03 |
ETIM number, version 7.0 |
EC002593 |
ETIM number, version 6.0 |
EC002593 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
Working principle |
induktiv |
Housing material |
Kunststoff, glasfaserverstärkter Thermoplast |
Reaction time, maximum |
150 ms |
Duration of risk, maximum |
150 ms |
Gross weight |
150 g |
General data - Features
Power to lock |
Ja |
Actuator monitored |
Ja |
Latching |
Ja |
Short circuit detection |
Ja |
Cross-circuit detection |
Ja |
Safety functions |
Ja |
Integral system diagnostics, status |
Ja |
Number of safety contacts |
2 |
Safety classification |
Vorschriften |
EN IEC 60947-5-3 EN IEC 61508 |
PFH value |
4,30 x 10⁻⁹ /h |
Mission time |
20 Year(s) |
Safety classification - Interlocking function
Performance Level, up to |
e |
Category |
4 |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mechanical data
Mechanical life, minimum |
1.000.000 Operations |
Note (Mechanical life) |
Schaltspiele bei Türmassen ≤ 5 kg |
Holding force |
500 N |
Latching force, minimum |
30 N |
Latching force, maximum |
80 N |
Mechanical data - Connection technique
Note (length of the sensor chain) |
Leitungslänge und Leitungsquerschnitt verändern den Spannungsfall in Abhängigkeit vom Ausgangsstrom |
Termination |
Einbaustecker M12, 8-polig |
Mechanical data - Dimensions
Length of sensor |
40 mm |
Width of sensor |
40 mm |
Height of sensor |
177,5 mm |
Ambient conditions
Degree of protection |
IP67 IP69K |
Ambient temperature |
-25 ... +55 °C |
Storage and transport temperature |
-25 ... +85 °C |
Relative humidity, minimum |
30 % |
Relative humidity, maximum |
95 % |
Note (Relative humidity) |
nicht kondensierend nicht vereisend |
Resistance to vibrations |
10 … 150 Hz, Amplitude 0,35 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
II |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0,8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
No-load supply current I0, typical |
600 mA |
Operating current |
50 mA |
Time to readiness, maximum |
4.000 ms |
Switching frequency, approx. |
1 Hz |
Electrical fuse rating, maximum |
2 A |
Electrical data - Magnet control
Switching thresholds |
-3 V … 5 V (Low) 15 V … 30 V (High) |
Magnet switch-on time |
100 % |
Electrical data - Safety digital inputs
Switching thresholds |
−3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V |
5 mA |
Electrical data - Safety digital outputs
Rated operating current (safety outputs) |
250 mA |
Voltage drop Ud, maximum |
1 V |
Leakage current Ir, maximum |
0,5 mA |
Electrical data - Diagnostic outputs
Voltage drop Ud, maximum |
2 V |
Status indication
Note (LED switching conditions display) |
Betriebszustand: gelbe LED Fehler Funktionsstörung: rote LED Versorgungsspannung UB vorhanden: grüne LED |
Pin assignment
PIN 1 |
A1 Versorgungsspannung Ub |
PIN 2 |
X1 Sicherheitseingang 1 |
PIN 3 |
A2 GND |
PIN 4 |
Y1 Sicherheitsausgang 1 |
PIN 5 |
OUT Diagnoseausgang |
PIN 6 |
X2 Sicherheitseingang 2 |
PIN 7 |
Y2 Sicherheitsausgang 2 |
PIN 8 |
IN Magnetansteuerung |
PIN 9 |
ohne Funktion |
Scope of delivery
Scope of delivery |
Der Betätiger ist nicht im Lieferumfang enthalten. |
Accessory
Recommendation (actuator) |
MZM 120-B1.1 |
Note
Note (General) |
Die entsperrte Schutzeinrichtung kann, solange die Schutzeinrichtung geschlossen bleibt, wieder gesperrt werden. Die Sicherheitsausgänge werden erneut eingeschaltet, somit ist ein Öffnen der Schutzeinrichtung nicht erforderlich. |
Sprachfilter
Datenblatt
Betriebsanleitung und Konformitätserklärung
UL-Zertifikat
SISTEMA-VDMA Bibliothek/Library
Download der aktuellen Version von Adobe Reader
Produktbild (Katalogeinzelphoto )
Maßzeichnung Grundgerät
Maßzeichnung Betätiger
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.
Generiert am: 27.03.2025, 09:18