schmersal_s_icon.png

SRB308IT-24VAC/DC

Numéro d'article: 101158200

Téléchargements

TraceParts Données
ePLAN Données
CADENAS Données CAO
SISTEMA Données
  • Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit recognition, Level 2: / Opener (NC) Normally open contact (NO)
  • Multifunctional safety relay module for superior diagnostics and visualisation
  • Suitable for the signal processing of outputs with contact sensors
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
  • Suitable for the signal processing of outputs with contact sensors
  • 3 safety contacts, STOP 0
  • 2 + 6 Signalling outputs

Ordering data

Note (Delivery capacity)

Plus disponible!

Replacement article number

101159511

Product type description

SRB308IT-24VAC/DC

Article number (order number)

101158200

EAN (European Article Number)

4250116201556

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

cULus

General data

Standards

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 61508

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-78

Housing material

Plastique, thermoplastique renforcée de fibres de verre, ventilée

Gross weight

480 g

General data - Features

Electronic Fuse

Oui

Wire breakage detection

Oui

Cross-circuit detection

Oui

Removable Terminals

Oui

Start input

Oui

Feedback circuit

Oui

Automatic reset function

Oui

Reset edge detection

Oui

Earth connection detection

Oui

Integral system diagnostics, status

Oui

Number of auxiliary contacts

2

Number of LEDs

5

Number of normally closed (NC)

2

Number of undelayed semi-conductor outputs with signaling function

6

Number of safety contacts

3

Number of signalling outputs

6

Safety classification

Vorschriften

EN IEC 60947-5-1

EN IEC 61508

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Stop-Category

0

Safety classification - Relay outputs

Performance Level, stop 0, up to

e

Category, Stop 0

4

Diagnostic Coverage (DC) Level, Stop 0

≥ 99 %

PFH value, Stop 0

2,00 x 10⁻⁸ /h

Safety Integrity Level (SIL), Stop 0, suitable for applications in

3

Mechanical data

Mechanical life, minimum

10 000 000 Operations

Mounting

Fixation rapide sur rails DIN standards selon DIN EN 60715

Mechanical data - Connection technique

Terminal designations

IEC/EN 60947-1

Termination

rigide ou flexible

Raccord fileté M20 x 1.5

Cable section, minimum

0,25 mm²

Cable section, maximum

2,5 mm²

Tightening torque of Clips

0,6 Nm

Mechanical data - Dimensions

Width

45 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature

-25 ... +45 °C

Storage and transport temperature

-40 ... +85 °C

Resistance to vibrations

10 ... 55 Hz, amplitude 0,35 mm

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution

2

Electrical data

Frequency range

50 Hz

60 Hz

Operating voltage

24 VAC -15 % / +10 %
24 VDC -15 % / +20 %

Ripple voltage

10 %

Rated operating voltage

24 VAC

Rated operating voltage

24 VDC

Operating current

125 mA

Rated AC voltage for controls, 50 Hz, minimum

20,4 VAC

Rated control voltage at AC 50 Hz, maximum

26,4 VAC

Rated AC voltage for controls, 60 Hz, minimum

20,4 VAC

Rated control voltage at AC 60 Hz, maximum

26,4 VAC

Rated AC voltage for controls at DC minimum

20,4 VDC

Rated control voltage at DC, maximum

28,8 VDC

Utilisation category AC-15

230 VAC

Utilisation category AC-15

1,5 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1,2 A

Electrical power consumption

3 W

Electrical power consumption

3 VA

Contact resistance, maximum

0,1 Ω

Note (Contact resistance)

à l'état neuf

Drop-out delay in case of "emergency stop", maximum

15 ms

Pull-in delay at automatic start, maximum, typically

60 ms

Pull-in delay at RESET, typically

200 ms

Material of the contacts, electrical

AgSn0, Ag-Ni, autonettoyant, à guidage forcé

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

Directive CEM

Status indication

Indicated operating states

Position relais K2

Position relais K1

Tension de service interne Ui

Position relais K3

Other data

Note (applications)

Dispositif de protection

Bouton d'arrêt d'urgence

Interrupteurs de sécurité à commande par câble

Rideau lumineux de sécurité

Note

Note (General)

Des charges inductives (p.ex. relais externe, etc.) doivent être antiparasitées par un dispositif approprié.

Wiring example

Note (Wiring diagram)

L'exemple de câblage est représenté pour les protecteurs fermés et hors tension.

Les tableaux ISD (système intégré de diagnostic) pour l'analyse des messages d'erreur et leurs causes sont repris en annexe.

Partie puissance: une commande à 2 canaux convient pour le renforcement ou la multiplication des contacts par contacteurs ou relais avec contacts à guidage forcé.

La commande détecte les courts-circuits transversaux, les ruptures de câbles et les fuites à la terre dans le circuit de surveillance.

Raccorder les sorties statiques à commutation p avec potentiel des rideaux lumineux/barrières immatérielles de sécurité à S12/S22. Les dispositifs doivent avoir le même potentiel de référence.

L'exemple reprend une commande à 2 canaux d'une surveillance de porte avec deux contacts, dont au moins un contact à manœuvre positive d'ouverture; avec interrupteur de réarmement externe (R) et boucle de retour (H2). (exemple sans détection des courts-circuits transversaux)

Pour une commande à 2 canaux avec détection des courts-circuits transversaux, raccorder le contact NF à S11/S12 et S31/S32 et ponter S21/S22

Pour une commande à 1 canal, raccorder le contact NF à S21/S22 et ponter S31/32

Fonction de démarrage / bouton de réarmement: la fonction "front descendant" est configurée via l'interrupteur AF (position de l'interrupteur = 1) situé sur la partie frontale du boîtier. Le démarrage automatique est configuré en reliant les bornes X3 / X5 et en basculant le commutateur "AF" sur 0. Le décalage temporel entre les canaux est d'environ 100 ms. Le décalage temporel "infini" entre les voies 1 et 2 est configurée par un pont entre les borniers X3 / X6.

F1 = fusible hybride

F2 = surveillance des sorties de signalisation

Filtre de langue

Mode d'emploi et déclaration de conformité

Exemple de câblage (câblage électrique)

Télécharger la dernière version d'Adobe Reader

103007672 SRB-E-301ST
  • Plug-in screw terminals with coding
  • STOP 0 Function
  • 1 oder 2-channel control
  • Start button / Auto-start
  • 1 Auxiliary contact
  • 3 safety contacts


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.

Généré le: 22/03/2025 05:03