SRB308IT-24VAC/DC
SRB308IT-24VAC/DC
Téléchargements
- Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit recognition, Level 2: / Opener (NC) Normally open contact (NO)
- Multifunctional safety relay module for superior diagnostics and visualisation
- Suitable for the signal processing of outputs with contact sensors
- Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
- Suitable for the signal processing of outputs with contact sensors
- 3 safety contacts, STOP 0
- 2 + 6 Signalling outputs
Ordering data
Note (Delivery capacity) |
Plus disponible! |
Replacement article number |
101159511 |
Product type description |
SRB308IT-24VAC/DC |
Article number (order number) |
101158200 |
EAN (European Article Number) |
4250116201556 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
Plastique, thermoplastique renforcée de fibres de verre, ventilée |
Gross weight |
480 g |
General data - Features
Electronic Fuse |
Oui |
Wire breakage detection |
Oui |
Cross-circuit detection |
Oui |
Removable Terminals |
Oui |
Start input |
Oui |
Feedback circuit |
Oui |
Automatic reset function |
Oui |
Reset edge detection |
Oui |
Earth connection detection |
Oui |
Integral system diagnostics, status |
Oui |
Number of auxiliary contacts |
2 |
Number of LEDs |
5 |
Number of normally closed (NC) |
2 |
Number of undelayed semi-conductor outputs with signaling function |
6 |
Number of safety contacts |
3 |
Number of signalling outputs |
6 |
Safety classification |
Vorschriften |
EN IEC 60947-5-1 EN IEC 61508 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
e |
Category, Stop 0 |
4 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
PFH value, Stop 0 |
2,00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Mechanical data
Mechanical life, minimum |
10 000 000 Operations |
Mounting |
Fixation rapide sur rails DIN standards selon DIN EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
rigide ou flexible Raccord fileté M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
45 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +45 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10 ... 55 Hz, amplitude 0,35 mm |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VAC -15 % / +10 % |
Ripple voltage |
10 % |
Rated operating voltage |
24 VAC |
Rated operating voltage |
24 VDC |
Operating current |
125 mA |
Rated AC voltage for controls, 50 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
1,5 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
1,2 A |
Electrical power consumption |
3 W |
Electrical power consumption |
3 VA |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
à l'état neuf |
Drop-out delay in case of "emergency stop", maximum |
15 ms |
Pull-in delay at automatic start, maximum, typically |
60 ms |
Pull-in delay at RESET, typically |
200 ms |
Material of the contacts, electrical |
AgSn0, Ag-Ni, autonettoyant, à guidage forcé |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
Directive CEM |
Status indication
Indicated operating states |
Position relais K2 Position relais K1 Tension de service interne Ui Position relais K3 |
Other data
Note (applications) |
Dispositif de protection Bouton d'arrêt d'urgence Interrupteurs de sécurité à commande par câble Rideau lumineux de sécurité |
Note
Note (General) |
Des charges inductives (p.ex. relais externe, etc.) doivent être antiparasitées par un dispositif approprié. |
Wiring example
Note (Wiring diagram) |
L'exemple de câblage est représenté pour les protecteurs fermés et hors tension. Les tableaux ISD (système intégré de diagnostic) pour l'analyse des messages d'erreur et leurs causes sont repris en annexe. Partie puissance: une commande à 2 canaux convient pour le renforcement ou la multiplication des contacts par contacteurs ou relais avec contacts à guidage forcé. La commande détecte les courts-circuits transversaux, les ruptures de câbles et les fuites à la terre dans le circuit de surveillance. Raccorder les sorties statiques à commutation p avec potentiel des rideaux lumineux/barrières immatérielles de sécurité à S12/S22. Les dispositifs doivent avoir le même potentiel de référence. L'exemple reprend une commande à 2 canaux d'une surveillance de porte avec deux contacts, dont au moins un contact à manœuvre positive d'ouverture; avec interrupteur de réarmement externe (R) et boucle de retour (H2). (exemple sans détection des courts-circuits transversaux) Pour une commande à 2 canaux avec détection des courts-circuits transversaux, raccorder le contact NF à S11/S12 et S31/S32 et ponter S21/S22 Pour une commande à 1 canal, raccorder le contact NF à S21/S22 et ponter S31/32 Fonction de démarrage / bouton de réarmement: la fonction "front descendant" est configurée via l'interrupteur AF (position de l'interrupteur = 1) situé sur la partie frontale du boîtier. Le démarrage automatique est configuré en reliant les bornes X3 / X5 et en basculant le commutateur "AF" sur 0. Le décalage temporel entre les canaux est d'environ 100 ms. Le décalage temporel "infini" entre les voies 1 et 2 est configurée par un pont entre les borniers X3 / X6. F1 = fusible hybride F2 = surveillance des sorties de signalisation |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Certificat UL
Exemple de câblage (câblage électrique)
Diagramme course-force
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Exemple de câblage
Exemple de câblage
Exemple de câblage
Symbole (norme technique)
103007672 SRB-E-301ST
- Plug-in screw terminals with coding
- STOP 0 Function
- 1 oder 2-channel control
- Start button / Auto-start
- 1 Auxiliary contact
- 3 safety contacts
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.