BN 32-R-1279-2 3,0M
BN 32-R-1279-2 3,0M
Downloads
- Cable output left and 2 shielding plates
- Non-contact principle
- 1 Reed contakts
- Long life
- Actuating surface and direction of actuation marked by switch symbol
- 85 mm x 26 mm x 24 mm
- Thermoplastic enclosure
- Actuating distance up to 55 mm depending on actuating magnet and version
Ordering data
Product type description |
BN 32-R-1279-2 3,0M |
Article number (order number) |
101093008 |
EAN (European Article Number) |
4030661025391 |
eCl@ss number, version 12.0 |
27-27-43-02 |
eCl@ss number, version 11.0 |
27-27-01-05 |
eCl@ss number, version 9.0 |
27-27-01-05 |
ETIM number, version 7.0 |
EC002544 |
ETIM number, version 6.0 |
EC002544 |
General data
Working principle |
magnetico |
Housing construction form |
parallelepipedo |
Housing material |
materiale sintetico, termoplastica rinforzata con fibra di vetro |
Active area |
materiale sintetico |
Gross weight |
210 g |
Note |
Integrated shielding plate (top and bottom) |
General data - Features
Latching |
Sì |
Suitable for elevators |
Sì |
Cable sleeve |
Sì |
Number of snap-in contacts |
1 |
Mechanical data
Active area |
lato frontale |
Actuating element |
magnete |
Mechanical lifetime, minimum |
1.000.000.000 Operations |
Actuation direction |
Lengthwise |
Actuating speed, maximum |
18 m/s |
Mounting |
lato posteriore con 2 perni filettati |
Mechanical data - Switching distances
Switching distance Sn |
5 mm … 55 mm 2 x BP 21S = 20 ... 55 mm BP 34S = 10 ... 25 mm BP 10N = 10 mm BP 10S = 10 mm 2 x BP 10N = 15 mm 2 x BP 10S = 15 mm BP 15N = 12 mm BP 15S = 12 mm 2 x BP 15/2N = 17 mm 2 x BP 15/2S = 17 mm BP 34N = 10 ... 25mm BP 20N = 5 ... 20 mm BP 20S = 5 ... 20 mm BP 31N = 5 ... 20 mm BP 31S = 5 ... 20 mm BP 11N = 10 mm BP 11S = 10 mm 2 x BP 11N = 20 mm 2 x BP 11S = 20 mm BP 12N = 15 mm BP 12S = 15 mm 2 x BP 12N = 10 ... 25 mm 2 x BP 12S = 10 ... 25 mm BP 21N = 15 ... 40 mm BP 21S = 15 ... 40 mm 2 x BP 21N = 20 ... 55 mm |
Note (Switching distance Sn) |
Distanza di commutazione fino a 55 mm, dipendente dal magnete di azionamento e versione |
Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-2 |
Repeat accuracy R |
0,3 mm |
Mechanical data - Connection technique
Length of cable |
3 m |
Cable entry |
back, right |
Termination |
Cavo di collegamento |
Number of cable wires |
2 |
Wire cross-section |
0,75 mm2 |
Wire cross-section |
18 AWG |
Material of the Cable mantle |
PVC |
Cable type |
H03VV-F |
Mechanical data - Dimensions
Length of sensor |
24 mm |
Width of sensor |
85 mm |
Height of sensor |
26 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-25 ... +90 °C |
Resistant to vibration |
15 g, oscillazione sinusoidale |
Electrical data
Switching voltage, maximum |
250 VAC |
|
Switching current, maximum |
3 A |
|
Switching capacity, maximum |
120 W |
|
Switching capacity, maximum |
120 VA |
|
Switching principle |
|
|
Bounce duration, minimum |
0,3 ms |
|
Bounce duration, maximum |
0,6 ms |
|
Switching frequency, maximum |
300 Hz |
|
Maximum switching time close (NO) |
1,5 ms |
|
Maximum switching time open (NC) |
0,5 ms |
|
Minimum switching time close (NO) |
0,3 ms |
Scope of delivery
Scope of delivery |
Actuator must be ordered separately. |
Accessory
Recommendation (actuator) |
BP 10 S 2x BP 10 S BP 15 S BP 34 S BP 20 S BP 31 S BP 11 S 2x BP 11 S BP 12 S BP 21 S 2x BP 21 S BP 10 N 2x BP 10 N BP 15 N 2 x BP 15/2 N 2x BP 15/2 S BP 34 N BP 20 N BP 31 N |
Note
Note (General) |
La funzione di apertura e di chiusura dipende dalla direzione di azionamento, dal magnete di azionamento e dalla polarità del magnete di azionamento. |
Filtro lingua
Scheda Tecnica
Manuale d'istruzioni e dichiarazione UE di conformità
Dichiarazione di conformità UE
Informazioni
Download dell'ultima versione di Adobe Reader
Immagine del prodotto (foto singola per catalogo)
Disegno quotato disp. di base
Disegno quotato disp. di base
Schema contatti
Diagramma curve caratteristiche
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
I dettagli e i dati qui riportati sono stati attentamente verificati. Le immagini possono differire dagli originali. Altri dati tecnici possono essere trovati nei manuali. Salvo modifiche tecniche o errori.
Generato il 08/08/2025, 08:00