schmersal_s_icon.png

CSS 12-34-V-SD-M-L

Numer katalogowy: 101181062

  • 1 x Pre-wired cable 8-pole
  • Actuation from top
  • serial diagnostic output
  • Max. 31 sensors can be wired in series.
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Misaligned actuation possible
  • 27 mm x 108.2 mm x 35 mm
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

Ordering data

Note (Delivery capacity)

Niedostępne!

Product type description

CSS 12-34-V-SD-M-L

Article number (order number)

101181062

EAN (European Article Number)

4030661314860

eCl@ss number, version 12.0

27-27-46-01

eCl@ss number, version 11.0

27-27-24-03

eCl@ss number, version 9.0

27-27-24-03

ETIM number, version 7.0

EC001829

ETIM number, version 6.0

EC001829

Approvals - Standards

Certificates

cULus

General data

Standards

EN IEC 60947-5-3

Working principle

indukcyjne

Housing construction form

Blok

Installation conditions (mechanical)

nie wpuszczany

Sensor topology

Czujnik do łaczenia szeregowego

Housing material

Tworzywo, Tworzywo termoplastyczne wzmocnione włóknem szklanym

Active area

Tworzywo, Tworzywo termoplastyczne wzmocnione włóknem szklanym

Reaction time, maximum

30 ms

Duration of risk, maximum

60 ms

Gross weight

300 g

General data - Features

Serial diagnostics

Tak

Diagnostic output

Tak

Short circuit detection

Tak

Cross-circuit detection

Tak

Safety functions

Tak

Cascadable

Tak

Integral system diagnostics, status

Tak

Number of LEDs

3

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of series-wiring of sensors

31

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Performance Level, up to

e

Category

4

PFH value

3,60 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Actuating panels

Aktywacja z góry

Active area

przód

Switching distance actuator

Actuator CST 34-V-1: 12 mm (typical switch distance Sn)

Actuator CST 34-V-1: 10 mm (ensured switch distance ON Sao)

Actuator CST 34-V-1: 15 mm (ensured switch distance OFF Sar)

Actuator CST 34-S-1 / CST 34-S-3: 15 mm (typical switch distance Sn)

Actuator CST 34-S-1 / CST 34-S-3: 13 mm (ensured switch distance ON Sao)

Actuator CST 34-S-1 / CST 34-S-3:: 18 mm (ensured switch distance OFF Sar)

Actuator CST 34-S-2: 10 mm (typical switch distance Sn)

Actuator CST 34-S-2: 8 mm (ensured switch distance ON Sao)

Actuator CST 34-S-2: 16 mm (ensured switch distance OFF Sar)

Actuator CST 180-1 / CST 180-2: 12 mm (typical switch distance Sn)

Actuator CST 180-1 / CST 180-2: 10 mm (ensured switch distance ON Sao)

Actuator CST 180-1 / CST 180-2: 16 mm (ensured switch distance OFF Sar)

Mechanical data - Switching distances

Hysteresis (Switching distance), maximum

1,5 mm

Repeat accuracy R

0,5 mm

Note (Repeat accuracy R)

Boczne przesunięcie: Powierzchnia górna pozwala na przesunięcie poprzeczne (z) maks. ± 8 mm (patrz rysunek: Zasada działania).

Mechanical data - Connection technique

Note (length of the sensor chain)

Cable length and cross-section change the voltage drop dependiing on the output current

Note (series-wiring)

Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Length of cable

1 m

Termination

Kabel (Y-UL 2517), 8-polowy

Cable section, maximum

8 x 0,35 mm²

Wire cross-section

22 AWG

Cable type

LiYY

Mechanical data - Dimensions

Length of sensor

35 mm

Width of sensor

27 mm

Height of sensor

108,2 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature

-25 ... +70 °C

Storage and transport temperature

-25 ... +85 °C

Resistance to vibrations

10 … 55 Hz, amplituda 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0,8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

No-load supply current I0, typical

100 mA

Operating current

600 mA

Required rated short-circuit current

100 A

Utilisation category DC-12

24 VDC

Utilisation category DC-12

0,05 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

0,05 A

Switching frequency, approx.

3 Hz

Utilisation category DC-12

24 VDC / 0,05 A

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0,25 A

Design of control elements

p-type

Voltage drop Ud, maximum

0,5 V

Leakage current Ir, maximum

0,5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,25 A

Electrical data - Diagnostic outputs

Design of control elements

typ p

Voltage drop Ud, maximum

5 V

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,05 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,05 A

Electrical data - Serial diagnostic SD

Designation, Serial diagnostic SD

OUT

Operation current

150 mA

Design of control elements

odporne na zwarcie, typu p

Wiring capacitance

50 nF

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

EMC rating

IEC 61000-6-2

Pin assignment

PIN 1

A1 Ue Brązowe

PIN 2

X1 Wejście bezpieczne 1 Białe

PIN 3

A2 GND Niebieskie

PIN 4

Y1 Wyjście bezpieczne 1 Czarne

PIN 5

SD szeregowe wyjście diagnostyczne: szary

PIN 6

X2 Wejście bezpieczne 2 fioletowe

PIN 7

Y2 Wyjście bezpieczne 2 czerwone

PIN 8

IN Szeregowe wejście diagnostyczne Różowe

Scope of delivery

Scope of delivery

Actuator must be ordered separately.

Accessory

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Note

Note (General)

Wymagania względem modułu bezpieczeństwa: 2-kanałowe wejście bezpieczne, odpowiednie dla czujników PNP z funkcją NO. Moduł bezpieczeństwa musi tolerować wewnętrzne testy czujników z cyklicznym wyłączaniem ich wyjść na maks. 0,5 ms. Moduł bezpieczeństwa nie musi dysponować funkcją detekcji zwarcia międzykanałowego.

Filtr językowy

Przykład połączeń (okablowanie elektryczne)

pobierz najnowszą wersję Adobe Reader

EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:CSS 34
Type:See ordering code
Description of the component:Non-contact safety sensor
Relevant Directives:Machinery Directive2006/42/EC
 EMC-Directive2014/30/EU
 RoHS-Directive2011/65/EU
Applied standards:EN 60947-5-3:2013
EN ISO 13849-1:2015
EN 61508 parts 1-7:2010
Notified body for Type Examination:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
Type Examination Certificate:01/205/5194.02/20
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, June 9, 2023
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director
UK Declaration of Conformity LOG_COM_lo1de01s
Company:K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom.
Name of the component:CSS 34
Type:See ordering code
Description of the component:Non-contact safety sensor
Relevant legislation:Supply of Machinery (Safety) Regulations2008
 Electromagnetic Compatibility Regulations2016
 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations2012
Designated standards:EN 60947-5-3:2013
EN ISO 13849-1:2015
EN 61508 parts 1-7:2010
Approved body for Type Examination:TÜV Rheinland UK Ltd.
1011 Stratford Road
Solihull, B90 4BN
ID: 2571
Type examination certificate:01/205U/5194.00/22
UK-Importer /
Person authorised for the compilation of the technical documentation:



Schmersal UK Ltd.
Paul Kenney
Unit 1, Sparrowhawk Close
Enigma Business Park
Malvern, Worcestershire, WR14 1GL
Place and date of issue:Wuppertal, June 9, 2023
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Dane zostały starannie sprawdzone. Zdjęcia mogą odbiegać od rzeczywistości. Dalsze dane techniczne znajdują się w instrukcji obsługi. Możliwe są zmiany i błędy techniczne.

Wygenerowano dnia 07.04.2025, 23:10