schmersal_s_icon.png

AZM 200SK-T-SD2PA

Artikelnummer: 101193284

Downloads

TraceParts CAD Data
CADENAS CAD Data
Produkttypebetegnelse:

AZM 200D(1)-T-1P2P2P(2)


(1)
SKSkrue terminaler
CCFjederforbindelse
ST1Stiktilslutning M23, (8+1-polet)
ST2Stiktilslutning M12, (8-polet)
ST3Indbygningsstik M23, 12 polet

(2)
udenSpænding for at åbne
ASpænding for at låse
Ikke alle komponent varianter, som er mulige iht. denne produktkode er tilgængelig og/eller teknisk mulig.
  • Guard locking monitored
  • serial diagnostic output
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Max. length of the sensor chain 200 m
  • 3 LEDs to show operating conditions
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm  vertically and ± 1,5 mm horizontally
  • Intelligent diagnosis
  • Manual release

Ordering data

Note (Delivery capacity)

Udgående produkt

Product type description

AZM 200SK-T-SD2PA

Article number (order number)

101193284

EAN (European Article Number)

4030661355313

eCl@ss number, version 12.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 9.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

cULus

General data

Standards

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 61508

Working principle

induktiv

Housing material

Plastik, glass-fibre reinforced thermoplastic

Reaction time, maximum

60 ms

Duration of risk, maximum

120 ms

Gross weight

598 g

General data - Features

Power to lock

Ja

Power to unlock

Ja

Actuator monitored

Ja

Solenoid interlock monitored

Ja

Serial diagnostics

Ja

Manual release

Ja

Short circuit detection

Ja

Safety functions

Ja

Integral system diagnostics, status

Ja

Number of safety contacts

2

Safety classification

Vorschriften

EN IEC 60947-5-3

EN IEC 61508

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

4,00 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Safety classification - Interlocking function 2

Performance Level, up to

d

Category

3

PFH value

1,00 x 10⁻⁷ /h

Safety Integrity Level (SIL), suitable for applications in

2

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

1.000.000 Operations

Holding force FZh in accordance with EN ISO 14119

2.000 N

Note (clamping force FZh)

1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use.

Holding force Fmax, maximum

2.600 N

Note (clamping force Fmax)

1.300 N in Verbindung mit einem Betätiger AZ/AZM201-B30 für Innenanbau.

Latching force

30 N

Actuating speed, maximum

0,2 m/s

Tightening torque of the fastening screws for the housing cover, minimum

0,7 Nm

Tightening torque of the fastening screws for the housing cover, maximum

1 Nm

Note

Torx T10

Mechanical data - Connection technique

Note (length of the sensor chain)

Cable length and cross-section change the voltage drop dependiing on the output current

Note (series-wiring)

Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Termination

Skrueforbindelse M20 x 1.5

Cable section, minimum

0,25 mm²

Cable section, maximum

1,5 mm²

Note

Alle oplysninger om tilslutningskabler er inkluderet kabelmuffer.

Wire cross-section, minimum

23 AWG

Wire cross-section, maximum

15 AWG

Wire cross-section

23 ... 15 AWG

Mechanical data - Dimensions

Length of sensor

50 mm

Width of sensor

40 mm

Height of sensor

220 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature

-25 ... +50 °C

Storage and transport temperature

-25 ... +85 °C

Resistance to vibrations

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0,8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 %

Rated operating voltage

24 VDC

Operating current

1.200 mA

Length of cable, maximum

200 m

Time to readiness, maximum

4.000 ms

Switching frequency, approx.

1 Hz

Electrical data - Magnet control

Switching thresholds

-3 V … 5 V (Low)

15 V … 30 V (High)

Magnet switch-on time

100 %

Electrical data - Safety digital inputs

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Electrical data - Safety digital outputs

Voltage drop Ud, maximum

4 V

Leakage current Ir, maximum

0,5 mA

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,25 A

Note, Utilisation category DC-13

Gælder for udgangene Y1 og Y2

Electrical data - Diagnostic outputs

Operating current

100 mA

Voltage drop Ud, maximum

4 V

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,05 A

Electrical data - Serial diagnostic SD

Designation, Serial diagnostic SD

OUT

Operation current

150 mA

Design of control elements

kortslutningssikker, P-type

Wiring capacitance

50 nF

Status indication

Note (LED switching conditions display)

Driftstilstand gul LED

Fejl Funktionsforstyrrelse: rød LED

Forsyningsspænding UB: grøn LED

Scope of delivery

Scope of delivery

Actuator must be ordered separately.

Trekant nøgle til AZM 200

Accessory

Recommendation (actuator)

AZ/AZM 200-B1

Note

Note (General)

Den frigivne beskyttelsesanordning kan låses igen, så længe aktuatorhovedet forbliver i sikkerhedspositionen. Sikkerhedsudgangene kobles atter til, og derfor er det ikke nødvendigt at åbne beskyttelsesanordningen.

Note (Actuator monitored)

Sikkerhedsudgange Y1, Y2

Note (Solenoid interlock monitored)

Sikkerhedsudgange Y3, Y4

Sprog filter

Ledningseksempel (el-ledningsføring)

Hent sidste version af Adobe Reader


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

De nævnte data og angivelser er blevet checket omhyggeligt. Billeder kan afvige fra originalen. Der kan findes flere tekniske data i manualen. Der tages forbehold for tekniske ændringer og fejl.

Udarbejdet d. 10.04.2025 19.10