AZM 200SK-T-SD2PA
AZM 200SK-T-SD2PA
Produkttypebetegnelse: AZM 200D(1)-T-1P2P2P(2) |
(1) | |
SK | Skrue terminaler |
CC | Fjederforbindelse |
ST1 | Stiktilslutning M23, (8+1-polet) |
ST2 | Stiktilslutning M12, (8-polet) |
ST3 | Indbygningsstik M23, 12 polet |
(2) | |
uden | Spænding for at åbne |
A | Spænding for at låse |
- Guard locking monitored
- serial diagnostic output
- Thermoplastic enclosure
- Electronic contact-free, coded system
- Max. length of the sensor chain 200 m
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 1,5 mm horizontally
- Intelligent diagnosis
- Manual release
Ordering data
Note (Delivery capacity) |
Udgående produkt |
Product type description |
AZM 200SK-T-SD2PA |
Article number (order number) |
101193284 |
EAN (European Article Number) |
4030661355313 |
eCl@ss number, version 12.0 |
27-27-26-03 |
eCl@ss number, version 11.0 |
27-27-26-03 |
eCl@ss number, version 9.0 |
27-27-26-03 |
ETIM number, version 7.0 |
EC002593 |
ETIM number, version 6.0 |
EC002593 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 61508 |
Working principle |
induktiv |
Housing material |
Plastik, glass-fibre reinforced thermoplastic |
Reaction time, maximum |
60 ms |
Duration of risk, maximum |
120 ms |
Gross weight |
598 g |
General data - Features
Power to lock |
Ja |
Power to unlock |
Ja |
Actuator monitored |
Ja |
Solenoid interlock monitored |
Ja |
Serial diagnostics |
Ja |
Manual release |
Ja |
Short circuit detection |
Ja |
Safety functions |
Ja |
Integral system diagnostics, status |
Ja |
Number of safety contacts |
2 |
Safety classification |
Vorschriften |
EN IEC 60947-5-3 EN IEC 61508 |
Safety classification - Interlocking function
Performance Level, up to |
e |
Category |
4 |
PFH value |
4,00 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Safety classification - Interlocking function 2 |
Performance Level, up to |
d |
Category |
3 |
PFH value |
1,00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Mission time |
20 Year(s) |
Mechanical data
Mechanical life, minimum |
1.000.000 Operations |
Holding force FZh in accordance with EN ISO 14119 |
2.000 N |
Note (clamping force FZh) |
1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use. |
Holding force Fmax, maximum |
2.600 N |
Note (clamping force Fmax) |
1.300 N in Verbindung mit einem Betätiger AZ/AZM201-B30 für Innenanbau. |
Latching force |
30 N |
Actuating speed, maximum |
0,2 m/s |
Tightening torque of the fastening screws for the housing cover, minimum |
0,7 Nm |
Tightening torque of the fastening screws for the housing cover, maximum |
1 Nm |
Note |
Torx T10 |
Mechanical data - Connection technique
Note (length of the sensor chain) |
Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series-wiring) |
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Termination |
Skrueforbindelse M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
1,5 mm² |
Note |
Alle oplysninger om tilslutningskabler er inkluderet kabelmuffer. |
Wire cross-section, minimum |
23 AWG |
Wire cross-section, maximum |
15 AWG |
Wire cross-section |
23 ... 15 AWG |
Mechanical data - Dimensions
Length of sensor |
50 mm |
Width of sensor |
40 mm |
Height of sensor |
220 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-25 ... +50 °C |
Storage and transport temperature |
-25 ... +85 °C |
Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
II |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0,8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC -15 % / +10 % |
Rated operating voltage |
24 VDC |
Operating current |
1.200 mA |
Length of cable, maximum |
200 m |
Time to readiness, maximum |
4.000 ms |
Switching frequency, approx. |
1 Hz |
Electrical data - Magnet control
Switching thresholds |
-3 V … 5 V (Low) 15 V … 30 V (High) |
Magnet switch-on time |
100 % |
Electrical data - Safety digital inputs
Switching thresholds |
−3 V … 5 V (Low) 15 V … 30 V (High) |
Electrical data - Safety digital outputs
Voltage drop Ud, maximum |
4 V |
Leakage current Ir, maximum |
0,5 mA |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,25 A |
Note, Utilisation category DC-13 |
Gælder for udgangene Y1 og Y2 |
Electrical data - Diagnostic outputs
Operating current |
100 mA |
Voltage drop Ud, maximum |
4 V |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,05 A |
Electrical data - Serial diagnostic SD
Designation, Serial diagnostic SD |
OUT |
Operation current |
150 mA |
Design of control elements |
kortslutningssikker, P-type |
Wiring capacitance |
50 nF |
Status indication
Note (LED switching conditions display) |
Driftstilstand gul LED Fejl Funktionsforstyrrelse: rød LED Forsyningsspænding UB: grøn LED |
Scope of delivery
Scope of delivery |
Actuator must be ordered separately. Trekant nøgle til AZM 200 |
Accessory
Recommendation (actuator) |
AZ/AZM 200-B1 |
Note
Note (General) |
Den frigivne beskyttelsesanordning kan låses igen, så længe aktuatorhovedet forbliver i sikkerhedspositionen. Sikkerhedsudgangene kobles atter til, og derfor er det ikke nødvendigt at åbne beskyttelsesanordningen. |
Note (Actuator monitored) |
Sikkerhedsudgange Y1, Y2 |
Note (Solenoid interlock monitored) |
Sikkerhedsudgange Y3, Y4 |
Sprog filter
Datablad
Driftsvejledning og Erklæring om konformitet
UL-certifikat
Ledningseksempel (el-ledningsføring)
Brochure
SISTEMA-VDMA bibliotek/library
Hent sidste version af Adobe Reader
Produktbillede (katalogenkeltfoto)
Dimensionstegning, grundlæggende komponent
Montageeksempel
Ledningseksempel
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
De nævnte data og angivelser er blevet checket omhyggeligt. Billeder kan afvige fra originalen. Der kan findes flere tekniske data i manualen. Der tages forbehold for tekniske ændringer og fejl.
Udarbejdet d. 10.04.2025 19.10