schmersal_s_icon.png

CSS 7-180LC-2P-E-L

Número de artículo: 101187081

Descargas

Trace Parts Datos CAD
ePLAN Datos
CADENAS Datos CAD
Product type description:

CSS 8-180-(1)-(2)-(3)


(1)
2P2 short-circuit proof PNP safety outputs
2P+D2 short-circuit proof PNP safety outputs and diagnostic output

(2)
EIndividual sensor or end sensor in a series
YSeries-wiring
MMultifunction connection

(3)
LCable
LSTCable with connector
STConnector plug
No todos los equipos posibles según este código de pedidos están disponibles y/o son realizables técnicamente.
  • Pre-wired cable 4-pole
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Misaligned actuation possible
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • Early warning when operating near the limit of the sensor's hysteris range
  • Self-monitoring series-wiring of 16 sensors
  • 2 short-circuit proof PNP safety outputs

Ordering data

Product type description

CSS 7-180LC-2P-E-L

Article number (order number)

101187081

EAN (European Article Number)

4030661334905

eCl@ss number, version 12.0

27-27-46-01

eCl@ss number, version 11.0

27-27-24-03

eCl@ss number, version 9.0

27-27-24-03

ETIM number, version 7.0

EC001829

ETIM number, version 6.0

EC001829

Approvals - Standards

Certificates

TÜV

cULus

UKCA

General data

Standards

EN IEC 60947-5-3

EN IEC 61508

Working principle

inductivo

Housing construction form

Cilindro, rosca

Installation conditions (mechanical)

no enrasado

Sensor topology

Sensor individual o primer sensor en serie

Housing material

Plástico reforzado con fibra de vidrio

Active area

Plástico reforzado con fibra de vidrio

Material of the nuts

Plástico reforzado con fibra de vidrio

Reaction time, maximum

30 ms

Duration of risk, maximum

30 ms

Gross weight

153 g

General data - Features

Short circuit detection

Cross-circuit detection

Safety functions

Integral system diagnostics, status

Number of fail-safe digital outputs

2

Number of series-wiring of sensors

16

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Performance Level, up to

e

Category

3

PFH value

1,00 x 10⁻⁸ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Tightening torque of nuts, maximum

3 Nm

Mechanical data - Switching distances

Switch distance, typical

7 mm

Assured switching distance "ON" Sao

6 mm

Assured switching distance "OFF" Sar

9 mm

Note (switching distance)

All switching distances in accordance EN IEC 60947-5-3

Hysteresis (Switching distance), maximum

0,7 mm

Repeat accuracy R

0,5 mm

Mechanical data - Connection technique

Length of cable

1 m

Termination

Cable

Terminal connector, Output

4-polos

Wire cross-section

0,5 mm2

Wire cross-section

20 AWG

Mechanical data - Dimensions

ISO thread of the sensor

M18

width across flats

24 BK

Length of sensor

92 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature

-25 ... +60 °C

Storage and transport temperature

-25 ... +85 °C

Resistance to vibrations

10…55 Hz, amplitud 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0,8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 %

No-load supply current I0, typical

50 mA

Rated operating voltage

24 VDC

Operating current

600 mA

Switching frequency, approx.

3 Hz

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

500 mA

Output current, (fail-safe output), maximum

0,5 A

Design of control elements

tipo p

Voltage drop Ud, maximum

0,5 V

Leakage current Ir, maximum

0,5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,5 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,5 A

Status indication

Note (LED switching conditions display)

LED multicolor: Verde, rojo, amarillo

Pin assignment

PIN 1

A1 Ue Marrón

PIN 2

Y2 salida de seguridad 2: blanco

PIN 3

A2 GND Azul

PIN 4

Y1 Salida de seguridad 1 Negro

Scope of delivery

Scope of delivery

Actuator must be ordered separately.

Scope of delivery of mounting material

2x tuercas M18 x 1

Accessory

Recommendation (actuator)

CST 180-1

CST 180-2

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Note

Note (General)

Wymagania względem modułu bezpieczeństwa: 2-kanałowe wejście bezpieczne, odpowiednie dla czujników PNP z funkcją NO. Moduł bezpieczeństwa musi tolerować wewnętrzne testy czujników z cyklicznym wyłączaniem ich wyjść na maks. 0,25 ms. Moduł bezpieczeństwa nie musi dysponować funkcją detekcji zwarcia międzykanałowego.

Filtro de idiomas

Ejemplo de cableado (cableado eléctr.)

Descargar la versión actual de Adobe Reader

Diagrama


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Los datos e información anteriores se han verificado cuidadosamente. Las imágenes pueden diferir del original. Se pueden encontrar más datos técnicos en los manuales de instrucciones. Sujeto a cambios técnicos y errores.

Generado a 11/4/2025 3:01