EX-BNS 250-11Z-3G/D 3,0M
EX-BNS 250-11Z-3G/D 3,0M
- Protection antidéflagrante pour les zones ATEX 2 et 22
- Boîtier plastique
- Permet un jeu mécanique
- pas d"usure mécanique
- 64 mm x 29,5 mm x 15,5 mm (y compris boîtier de protection)
Exemple de commande
Note (disponibilité) |
Plus disponible! |
Désignation de type du produit |
EX-BNS 250-11Z-3G/D 3,0M |
Référence d’article (n° de commande) |
101192532 |
EAN (European Article Number) |
4030661352787 |
eCl@ss number, version 12.0 |
27-27-44-01 |
eCl@ss number, version 11.0 |
27-27-24-02 |
Numéro eCl@ss, version 9.0 |
27-27-24-02 |
ETIM number, version 7.0 |
EC002544 |
ETIM number, version 6.0 |
EC002544 |
Homologations - Règlementations
|
ATEX (Konformitätserklärung) |
Protection antidéflagrante
Protection antidéflagrante: Normes de référence |
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31 |
Zones de protection antidéflagrante |
2 22 |
Catégorie de protection antidéflagrante |
3G 3D |
Etiquetage protection antidéflagrante |
D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
Déclaration du constructeur |
ATEX Zone 2 et 22 |
Caractéristiques globales
Modèle de boîtier |
Bloc |
Conditions de montage (mécaniques) |
non affleuré |
Matériau du boîtier |
Plastique, thermoplastique renforcé de fibres de verre |
Poids brut |
130 g |
Données générales - Caractéristiques
Codage |
Oui |
Condition préalable Unité d’évaluation |
Oui |
Nombre de contacts NF |
1 |
Nombre de contacts NO |
1 |
Classification
Normes de référence |
EN ISO 13849-1 |
Durée d'utilisation |
20 année(s) |
Classification de sécurité - Sorties de sécurité
Valeur B10D, contact NC/NO |
25.000.000 manœuvres |
Données mécaniques
Surface active |
côté avant |
Actionneur |
Aimant |
Energie d'impact, max. |
7 J |
Direction de mouvement |
Frontale par rapport à la face active |
Mechanical data - Switching distances
Intervalle de commutation protégé MARCHE |
4 mm |
Intervalle de commutation protégé ARRET |
14 mm |
Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-3 |
Données mécaniques – technique de connexion
Longueur du câble |
3 m |
Connecteur de raccordement |
câble |
Nombre de conducteurs de câble |
4 |
Section des conducteurs |
0,25 mm2 |
Section des conducteurs |
23 AWG |
Matériau de la gaine de câble |
PVC |
Données mécaniques - Dimensions
Longueur du capteur |
13 mm |
Largeur du capteur |
33 mm |
Hauteur du capteur |
25 mm |
Conditions ambiantes
Etanchéité |
IP67 |
Ambient temperature |
-25 ... +70 °C |
Storage and transport temperature |
-25 ... +70 °C |
Tenue aux vibrations selon EN 60068-2-6 |
10…55 Hz, amplitude 1 mm |
Tenue aux chocs mécaniques |
30 g / 11 ms |
Données électriques
Tension commutable, max. |
24 VDC |
Courant commutable, max. |
0,1 A |
Puissance commutable, max. |
1 W |
Elément de commutation |
1 contact NO, 1 contact NF |
Principe de commutation |
Contacts Reed, fonctionnant sans contact |
Fréquence de commutation, max. |
5 Hz |
Inclus dans la livraison
Inclus dans la livraison |
Actuator must be ordered separately. |
Accessoires
Recommandation (actionneur) |
EX-BPS 250-3G/D |
Recommandation dispositif de commutation de sécurité |
SRB-E-301ST SRB-E-201LC |
Remarque
Remarque (en général) |
Symboles des contacts, protecteur fermé. La configuration des contacts pour les versions avec ou sans LED est identique. |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Bibliothèque/Library SISTEMA-VDMA
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Plan d'encombrement composant de base
Diagramme de contact
Courbe caractéristique
103045518 EX-BNS 250-11Z-3GD 3M
- Protection antidéflagrante pour les zones ATEX 2 et 22
- Boîtier plastique
- Permet un jeu mécanique
- pas d"usure mécanique
- 64 mm x 29,5 mm x 15,5 mm (y compris boîtier de protection)
UK Declaration of Conformity | ![]() |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | EX-BNS 250 | EX-BPS 250 |
Type: | See ordering code |
Marking: | D II 3G Ex nC IIC T6 Gc D II 3D Ex tc IIIC T80°C Dc | D II 3G Ex h IIC T6 Gc D II 3D Ex h IIIC T80°C Dc |
Description of the component: | Coded safety-sensor with magnetic operating principle in combination with the SRB(-E) / PROTECT-SELECT / PSC1 safety-monitoring modules from Schmersal or an equivalent safety-oriented control system fulfilling the requirements of the EN 60947-5-3. |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN 60947-5-3:2013 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 EN ISO 80079-36:2016 EN ISO 80079-37:2016 |
Conformity with SI 2016/1107 (Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations) is declared by the manufacturer without involving a conformity assessment center. |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, November 10, 2022 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Déclaration UE de conformité | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Déclaration: | Par la présente, nous certifions que les composants identifiés ci-après répondent de par leur conception et leur construction aux exigences des Directives Européennes applicables. |
Désignation du composant: | EX-BNS 250 | EX-BPS 250 |
Type: | voir exemple de commande |
Marquage: | D II 3G Ex nC IIC T6 Gc D II 3D Ex tc IIIC T80°C Dc | D II 3G Ex h IIC T6 Gc D II 3D Ex h IIIC T80°C Dc |
Description du composant: | Capteur de sécurité magnétique codé en liaison avec les modules de sécurité SRB(-E) / PROTECT-SELECT / PSC1 de Schmersal ou un système de contrôle-commande relatif à la sécurité comparable répondant aux exigences de la norme EN 60947-5-3. |
Directives pertinentes: | Directive Machines | 2006/42/CE |
Directive ATEX Constructeur (Atmosphères Explosibles) | 2014/34/EU | |
Directive RoHS | 2011/65/EU |
Normes appliquées: | EN 60947-5-3:2013 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 EN ISO 80079-36:2016 EN ISO 80079-37:2016 |
Représentant autorisé à préparer et composer la documentation technique: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
La conformité avec la directive ATEX 2014/34/EU est attestée par le fabricant sans l'intervention d'un organisme de certification. |
Lieu et date de l'émission: | Wuppertal, le 10 mai 2022 |
![]() |
Signature à l'effet d'engager la société Philip Schmersal Président Directeur Général |
Schmersal Belgium, Nieuwlandlaan 73, 3200 Aarschot
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 24/07/2025 08:47