AES 2366 UE: 24...230V AC/DC
AES 2366 UE: 24...230V AC/DC
- Monitoring of BNS range magnetic safety sensors
- 3 safety contacts, STOP 0
- 2 Signalling outputs
Ordering data
Note (Delivery capacity) |
Plus disponible! |
Product type description |
AES 2366 UE: 24...230V AC/DC |
Article number (order number) |
101181687 |
EAN (European Article Number) |
4030661323183 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Notice |
Produit de fin de série |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
BG-GS-ET-14 BG-GS-ET-20 EN IEC 62061 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-3 BG-GS-ET-14 |
Housing material |
Plastique, thermoplastique renforcé de fibres de verre |
Gross weight |
125 g |
General data - Features
Wire breakage detection |
Oui |
Cross-circuit detection |
Oui |
Feedback circuit |
Oui |
Automatic reset function |
Oui |
Start-up test |
Oui |
Reset after disconnection of supply voltage |
Oui |
Integral system diagnostics, status |
Oui |
Number of LEDs |
1 |
Number of normally closed (NC) |
2 |
Number of normally open (NO) |
2 |
Number of undelayed semi-conductor outputs with signaling function |
2 |
Number of safety contacts |
3 |
Number of signalling outputs |
2 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 61508 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, up to |
d |
Category |
3 |
PFH value |
1,00 x 10⁻⁷ /h |
Notice |
applicable pour les applications jusqu'à max. 50 000 manoeuvres/an et une charge de contact de 80% max. |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Mission time |
20 Year(s) |
Mechanical data
Mechanical life, minimum |
20 000 000 Operations |
Mounting |
Fixation rapide sur rails DIN standards selon DIN EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
rigide ou flexible Raccord fileté M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
45 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
+0 ... +55 °C |
Storage and transport temperature |
-25 ... +70 °C |
Resistance to vibrations |
10...55 Hz, amplitude 0,35 mm, ± 15 % |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Type of voltage range |
AC DC |
Thermal test current |
6 A |
Rated operating voltage |
24 ... 230 VAC |
Rated AC voltage for controls, 50 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 50 Hz, maximum |
253 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 60 Hz, maximum |
253 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
253 VDC |
Electrical power consumption |
5 W |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
à l'état neuf |
Drop-out delay in case of power failure, typically |
80 ms |
Drop-out delay in case of emergency, typically |
20 ms |
Pull-in delay at automatic start, maximum, typically |
100 ms |
Pull-in delay at RESET, typically |
20 ms |
Material of the contacts, electrical |
Ag-Ni 10 et 0,2 µm dorés |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
3 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
2 A |
Switching capacity, minimum |
10 VDC |
Switching capacity, minimum |
10 mA |
Switching capacity, maximum |
250 VAC |
Switching capacity, maximum |
8 A |
Electrical data - Digital inputs
Input signal, HIGH Signal "1" |
10 … 30 VDC |
Input signal, LOW Signal "0" |
0 … 2 VDC |
Conduction resistance, maximum |
40 Ω |
Electrical data - Digital Output
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,1 A |
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum |
24 VDC |
Switching capacity, maximum |
2 A |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
Directive CEM |
Integral system diagnosis (ISD)
Note (ISD -Faults) |
Les erreurs suivantes sont reconnues par le module de sécurité et affichées par l' ISD. |
Faults |
Non-enclenchement ou non-déclenchement des relais de sécurité Non-ouverture ou non-fermeture des contacts de la porte Courts-circuits transversaux ou courts-circuits des câbles d'entrée Coupure des câbles d'entrée Erreurs sur le câblage d'entrée ou sur la commande des relais du module de sécurité |
Other data
Note (applications) |
Capteur de sécurité Dispositif de protection |
Note
Note (General) |
Des charges inductives (p.ex. relais externe, etc.) doivent être antiparasitées par un dispositif approprié. |
Wiring example
Note (Wiring diagram) |
L'exemple de câblage est représenté pour les protecteurs fermés et hors tension. Surveillance de 2 protecteur(s) avec chacun un capteur de sécurité magnétique de la série BNS Pour la surveillance d'un protecteur jusqu'à max. PL d et catégorie 3 Les tableaux ISD (système intégré de diagnostic) pour l'analyse des messages d'erreur et leurs causes sont repris en annexe. Bouton de réarmement: Un bouton de réarmement (contact NO) peut éventuellement être intégré dans la boucle de retour. Si le protecteur est fermé, les sorties de sécurité se ferment seulement après actionnement du bouton de réarmement. Prolongation de la temporisation de sortie: par le pontage des bornes X7 et X8 la temporisation de sortie peut être de 0,1 s ou 1 s. Si aucun bouton de réarmement ni boucle de retour ne sont raccordés, X1 et S2 doivent être pontés. |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Certificat UL
Exemple de câblage (câblage électrique)
Diagramme course-force
Bibliothèque/Library SISTEMA-VDMA
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Photo du produit (photo individuelle de catalogue)
Exemple de câblage
103009973 SRB-E-204ST
- Plug-in screw terminals with coding
- STOP 0 Function
- Monitoring of 4 sensors
- Start button / Auto-start
- 2 Safety outputs
- 4 Signalling outputs
103015923 ML30.241-70
- 1-phase DIN rail power supplies
- AC 100-240V Wide-range input
- DC Output 24-28VDC / 1,3-1,1A / 30W
- Efficiency up to 89,4%
- Width only 22,5mm
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 10/04/2025 11:11