AZM 161ST-11/12I-024-B6R
AZM 161ST-11/12I-024-B6R
- Large wiring compartment
- Manual release
- 2 Connector M12, 4- and 8-poles
- right-hand model
- Compact design
- For very smal actuating radii in line with or at 90° to the plane of the actuator
- Interlock with protection against incorrect locking.
- Individual coding
- Coding level "High" according to ISO 14119
- Double-insulated
- High holding force
- Long life
- 130 mm x 90 mm x 30 mm
Ordering data
Product type description |
AZM 161ST-11/12I-024-B6R |
Article number (order number) |
103025178 |
EAN (European Article Number) |
4030661512389 |
eCl@ss number, version 12.0 |
27-27-26-03 |
eCl@ss number, version 11.0 |
27-27-26-03 |
eCl@ss number, version 9.0 |
27-27-26-03 |
ETIM number, version 7.0 |
EC002593 |
ETIM number, version 6.0 |
EC002593 |
Approvals - Standards
Certificates |
IFA cULus CCC |
General data
Standards |
EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 |
Coding |
individuelt kodet |
Coding level according to EN ISO 14119 |
Høy |
Working principle |
elektromekanisk |
Housing material |
Plast, glassfiber forsterket termoplast, selvslukkende |
Material of the actuator |
Rustfritt stål |
Gross weight |
400 g |
General data - Features
Power to unlock |
Ja |
Manual release |
Ja |
Number of actuating directions |
3 |
Number of auxiliary contacts |
1 |
Number of safety contacts |
3 |
Safety classification |
Vorschriften |
EN ISO 13849-1 |
Performance Level, up to |
c |
Category |
1 |
B10D Normally-closed contact (NC) |
2.000.000 Operations |
Note |
Electrical life on request. |
B10D Normally-open contact (NO) |
1.000.000 Operations |
Note |
at 10% Ie and ohmic load |
Mission time |
20 Year(s) |
Safety classification - Safety outputs
Note (B10D Normally open contact (NO)) |
På 10% Ie og ohmsk last |
Safety classification - Fault exclusion |
Please note: |
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. |
Performance Level, up to |
d |
Category |
3 |
Note |
for 2-channel use and with suitable logic unit. |
Mission time |
20 Year(s) |
Safety classification - Guard locking function
Performance Level, up to |
e |
Note (Performance Level) |
Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions. |
Mechanical data
Actuating radius, minimum |
95 mm |
Mechanical lifetime, minimum |
1.000.000 Operations |
Actuating play in direction of actuation |
5,5 mm |
Holding force FZh in accordance with EN ISO 14119 |
2.000 N |
Holding force Fmax, maximum |
2.600 N |
Latching force |
30 N |
Positive break travel |
10 mm |
Positive break force per NC contact, minimum |
10 N |
Positive break force, minimum |
20 N |
Actuating speed, maximum |
2 m/s |
Mounting |
Skruer |
Type of the fixing screws |
3x M6 |
Mechanical data - Connection technique
Termination |
Konnektorplugg M12, 4-polet, A-koding Konnektorplugg M12, 8-polet, A-koding |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
1,5 mm² |
Note |
Alle indikasjoner om kabelsnittet inkluderer lederhylsene. |
Mechanical data - Dimensions
Length of sensor |
30 mm |
Width of sensor |
130 mm |
Height of sensor |
90 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-30 ... +60 °C |
Note (Relative humidity) |
ikke kondenserende ikke-ising |
Protection class |
II |
Permissible installation altitude above sea level, maximum |
2.000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
Stik 4-polet - 250 V Stik 8-polet - 60 V |
Rated impulse withstand voltage Uimp |
4 kV |
Rated impulse withstand voltage, connector 4-pole |
2.5 kV |
Rated impulse withstand voltage, connector 8-pole |
0.8 kV |
Electrical data
Thermal test current |
2 A |
Rated control voltage |
24 VAC/DC |
Required rated short-circuit current |
1.000 A |
Electrical power consumption, maximum |
10 W |
Switching element |
NO-kontakt, NC-kontakt |
Switching principle |
slow action, positive break NC contact |
Maximale Schalthäufigkeit |
1.000 /h |
Material of the contacts, electrical |
Sølv |
Electrical data - Magnet control
Magnet switch-on time |
100 % |
Test pulse duration, maximum |
5 ms |
Test pulse interval, minimum |
50 ms |
Electrical data - Safety contacts
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
4 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
2,5 A |
Electrical data - Auxiliary contacts
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
4 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
2,5 A |
Other data
Note (applications) |
skyvbar sikkerhetsvern avtakbare vern hengslet beskyttelsesanordning |
Scope of delivery
Scope of delivery |
Ikke tilgjengelig som reservedel Slissetetning The actuator is included in the scope of delivery |
Note
Note (General) |
Akselen på hengselet bør være 11 mm over toppkanten av sikkerhetsbryteren og på samme plan Betätigungsradius einstellbar bis minimal 95 mm mit einem Innensechskant-Schlüssel SW 2 mm (a) Aktivatoren er ikke tilgjengelig separat. |
Note (Manual release) |
For vedlikehold, installasjon etc. For manuell frigjøring ved hjelp av M5 trekantnøkkel, tilgjengelig som tilbehør |
Språk filter
Datablad
Bruksanvisning og konformitetserklæring
UL sertifikat
DGUV-sertifikat
CCC-sertifisering
Brosjyre
Last ned den nyeste versjonen av Adobe Reader
Produktbilde (enkelt katalogbilde)
Dimensjonsriktig tegning grunnenhet
Dimensjonsriktig tegning betjener
Kontaktplassering
Kontaktplassering
kablingseksempel
Funksjonsprinsipp
UK Declaration of Conformity | ![]() |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | AZM 161 I |
Type: | See ordering code |
Description of the component: | Interlocking device with electromagnetic interlock for safety functions |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Electromagnetic Compatibility Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN 60947-5-1:2017 EN ISO 14119:2013 |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, March 30, 2023 |
![]() |
Authorised signature Philip Schmersal Managing Director |
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | AZM 161 I |
Type: | See ordering code |
Description of the component: | Interlocking device with electromagnetic interlock for safety functions |
Relevant Directives: | Machinery Directive | 2006/42/EC |
EMC-Directive | 2014/30/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | DIN EN 60947-5-1:2018 EN ISO 14119:2013 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, November 9, 2021 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Data og verdier er kontrollert omhyggelig. Bilder kan avvike fra originalen. Ytterligere tekniske data finner du i manualen. Tekniske modifiseringer og feil kan forkomme.
Generert til 30.08.2025, 06:04