MS-AZM 200 D ST3-T-1P2P2P-2568
MS-AZM 200 D ST3-T-1P2P2P-2568
Produkt-typebetegnelse: AZM 200D(1)-T-1P2P2P(2) |
(1) | |
SK | Skrueforbindelse |
CC | Fjærtrinseforbindelse |
ST1 | Konnektor M23, (8+1-polet) |
ST2 | Konnektor M12, 8-polet |
ST3 | Konnektorplugg M23, 12-polet |
(2) | |
uten | åpner med spenning |
A | driftsspenning |
- Guard locking monitored
- Thermoplastic enclosure
- Electronic contact-free, coded system
- Max. length of the sensor chain 200 m
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Intelligent diagnosis
- Manual release
Ordering data
Note (Delivery capacity) |
Ikke tilgjengelig! |
Product type description |
MS-AZM 200 D ST3-T-1P2P2P-2568 |
Article number (order number) |
103006851 |
EAN (European Article Number) |
4030661443348 |
eCl@ss number, version 12.0 |
27-27-26-03 |
eCl@ss number, version 11.0 |
27-27-26-03 |
eCl@ss number, version 9.0 |
27-27-26-03 |
ETIM number, version 7.0 |
EC002593 |
ETIM number, version 6.0 |
EC002593 |
General data
Standards |
EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 61508 |
Coding |
Universell koding |
Coding level according to EN ISO 14119 |
lav |
Working principle |
induktiv |
Housing material |
Plast, glassfiber forsterket termoplast |
Reaction time, maximum |
60 ms |
Duration of risk, maximum |
120 ms |
Gross weight |
720 g |
General data - Features
Power to unlock |
Ja |
Actuator monitored |
Ja |
Solenoid interlock monitored |
Ja |
Manual release |
Ja |
Short circuit detection |
Ja |
Safety functions |
Ja |
Integral system diagnostics, status |
Ja |
Number of safety contacts |
4 |
Safety classification |
Vorschriften |
EN IEC 60947-5-3 EN IEC 61508 |
Safety classification - Interlocking function
Performance Level, up to |
e |
Category |
4 |
PFH value |
4,00 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Safety classification - Interlocking function 2 |
Performance Level, up to |
d |
Category |
3 |
PFH value |
1,00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Mission time |
20 Year(s) |
Mechanical data
Mechanical life, minimum |
1.000.000 Operations |
Holding force FZh in accordance with EN ISO 14119 |
2.000 N |
Note (clamping force FZh) |
1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use. |
Holding force Fmax, maximum |
2.600 N |
Note (clamping force Fmax) |
1.300 N in Verbindung mit einem Betätiger AZ/AZM201-B30 für Innenanbau. |
Latching force |
30 N |
Actuating speed, maximum |
0,2 m/s |
Tightening torque of the fastening screws for the housing cover, minimum |
0,7 Nm |
Tightening torque of the fastening screws for the housing cover, maximum |
1 Nm |
Note |
Torx T10 |
Mechanical data - Connection technique
Note (length of the sensor chain) |
Cable length and cross-section change the voltage drop dependiing on the output current |
Termination |
Konnektor M23, 12-polet |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
1,5 mm² |
Note |
Alle indikasjoner om kabelsnittet inkluderer lederhylsene. |
Wire cross-section, minimum |
23 AWG |
Wire cross-section, maximum |
15 AWG |
Mechanical data - Dimensions
Length of sensor |
50 mm |
Width of sensor |
40 mm |
Height of sensor |
220 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-25 ... +60 °C |
Storage and transport temperature |
-25 ... +85 °C |
Resistance to vibrations |
10 … 55 Hz, Amplitude 1 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
II |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0,8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC -15 % / +10 % |
No-load supply current I0, typical |
500 mA |
Rated operating voltage |
24 VDC |
Operating current |
1.200 mA |
Length of cable, maximum |
200 m |
Time to readiness, maximum |
4.000 ms |
Switching frequency, approx. |
1 Hz |
Electrical data - Magnet control
Switching thresholds |
-3 V … 5 V (Low) 15 V … 30 V (High) |
Magnet switch-on time |
100 % |
Electrical data - Safety digital outputs
Voltage drop Ud, maximum |
4 V |
Leakage current Ir, maximum |
0,5 mA |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,25 A |
Note, Utilisation category DC-13 |
Gilt für die Ausgänge Y1 und Y2 |
Electrical data - Diagnostic outputs
Operating current |
100 mA |
Voltage drop Ud, maximum |
4 V |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,05 A |
Status indication
Note (LED switching conditions display) |
Koblingsforhold: gul lysdiode Feil funksjonell defekt: rød lysdiode Tilførselsspenning UB: grønn lysdiode |
Scope of delivery
Scope of delivery |
Actuator must be ordered separately. Trekantnøkkel for AZM 200 |
Accessory
Recommendation (actuator) |
AZ/AZM 200-B1 |
Note
Note (General) |
Så lenge aktueringsenheten forblir satt inn i den magnetiske forriglingen, kan den ulåste sikkerhetsvakten låses på nytt. Sikkerhetsutgangene vil så bli aktivert igjen. Det er derfor ikke nødvendig å åpne vakten. |
Note (Actuator monitored) |
Sikkerhetsutganger Y1, Y2 |
Note (Solenoid interlock monitored) |
Sikkerhetsutganger Y3, Y4 |
Språk filter
Datablad
Bruksanvisning og konformitetserklæring
Info
Brosjyre
SISTEMA-VDMA Bibliotek/Library
Last ned den nyeste versjonen av Adobe Reader
Produktbilde (enkelt katalogbilde)
Dimensjonsriktig tegning grunnenhet
kablingseksempel
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Data og verdier er kontrollert omhyggelig. Bilder kan avvike fra originalen. Ytterligere tekniske data finner du i manualen. Tekniske modifiseringer og feil kan forkomme.
Generert til 08.06.2025, 20:12