AZ315-T12
AZ315-T12
- Design to EN 50041
- Metal enclosure
- Actuator heads can be repositioned in steps 4 x 90°
- Different contact options
- Latching force 12N or 30N depending on variant
Ordering data
Product type description |
AZ315-T12 |
Article number (order number) |
103049880 |
EAN (European Article Number) |
4030661625492 |
eCl@ss number, version 12.0 |
27-27-06-10 |
eCl@ss number, version 11.0 |
27-27-06-10 |
eCl@ss number, version 9.0 |
27-27-06-10 |
ETIM number, version 7.0 |
EC002592 |
ETIM number, version 6.0 |
EC002592 |
Approvals - Standards
Certificates |
cULus CCC |
General data
Standards |
EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 |
Coding level according to EN ISO 14119 |
baixa |
Working principle |
eletromecânico |
Housing material |
Filme metálico, zinco fundido sob pressão |
Housing coating material |
pintura de fábrica |
Gross weight |
421 g |
General data - Features
Number of auxiliary contacts |
1 |
Number of safety contacts |
2 |
Number of cable glands |
1 |
Safety classification |
Standards |
EN ISO 13849-1 |
Performance Level, up to |
c |
Category |
1 |
B10D Normally-closed contact (NC) |
2.000.000 Operations |
B10D Normally-open contact (NO) |
1.000.000 Operations |
Note |
a 10% le e carga resistiva |
Mission time |
20 Year(s) |
Safety classification - Fault exclusion |
Please note: |
Adequado para utilização se uma exclusão de falhas para uma avaria perigosa do canal mecânico 1 for autorizada e uma proteção contra manipulação adequada for assegurada. |
Performance Level, up to |
d |
Category |
3 |
Note |
para utilização de 2 canais e com unidade lógica adequada. |
Mechanical data
Mechanical lifetime, minimum |
1.000.000 Operations |
Latching force |
12 N |
Positive break travel |
5 mm |
Positive break force per NC contact, minimum |
10 N |
Positive break force, minimum |
20 N |
Actuating speed, maximum |
0,2 m/s |
Mounting |
parafusos |
Type of the fixing screws |
2XM4 |
Tightening torque of the fixing screws |
2 Nm |
Tightening torque of the fastening screws for the housing cover |
2,6 Nm |
Mechanical data - Connection technique
Type of electrical connection |
Ligação por parafuso M20 x 1.5 |
Cable entry |
1 x M20 x 1,5 |
Note (Cable entry) |
Absetzlänge des Leiters 5...6mm |
Termination |
Bornes com rosca |
Cable section, minimum |
0,34 mm² |
Cable section, maximum |
1,5 mm² |
Note |
Todas as especificações incluindo ponteiras de cabo. |
Tightening torque of electrical connection, minimum |
0,6 Nm |
Tightening torque of electrical connection, maximum |
0,8 Nm |
Allowed type of cable |
Rígido de um fio Rígido de vários fios Flexível |
Mechanical data - Dimensions
Length of sensor |
37 mm |
Width of sensor |
40 mm |
Height of sensor |
113,8 mm |
Ambient conditions
Degree of protection |
IP66 IP67 |
Ambient temperature |
-30 ... +80 °C |
Storage and transport temperature |
-40 ... +85 °C |
Permissible installation altitude above sea level, maximum |
2.000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
300 VAC |
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
I |
Degree of pollution |
3 |
Electrical data
Thermal test current |
5 A |
Required rated short-circuit current |
400 A |
Switching element |
1 contacto normalmente aberto (NA), 2 contactos normalmente fechados (NF) |
Note (Switching element) |
Comutador com dupla interrupção Zb ou 3 NF com ponte de contactos isolada galvanicamente |
Switching principle |
Comutação de ação lenta, contacto de rutura positiva |
Maximale Schalthäufigkeit |
1.200 /h |
Material of the contacts, electrical |
Prata |
Electrical data - Safety contacts
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
3 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
3 A |
Electrical data - Auxiliary contacts
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
3 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
3 A |
Other data
Note (applications) |
Dispositivo de segurança deslocável Proteção móvel Dispositivo de segurança giratório |
Scope of delivery
Scope of delivery |
O atuador não está incluído no fornecimento. Proteção de fendas para cobertura resistente ao pó da abertura não utilizada |
Filtro de idioma
Ficha técnica
Manual de instruções e Declaração de conformidade
Certificação CCC
SISTEMA-VDMA Biblioteca/Library
Faça download da versão mais recente do Adobe Reader
Foto do produto (foto individual do catálogo )
Desenho dimensional componente básico
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | AZ215 AZ216 AZ315 AZ316 |
Type: | See ordering code |
Description of the component: | Positive break position switch with separate actuator for safety functions |
Relevant Directives: | Machinery Directive | 2006/42/EC |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 60947-5-1:2017 + AC:2020 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, August 4, 2023 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Os dados e informações anteriores foram verificados cuidadosamente. As imagens podem ser diferentes do original. Mais informações técnicas podem ser encontradas nos manuais de instruções. Sujeito a modificações técnicas e erros.
Gerado em 27/09/2025 18:06