SLG445-ER-0900-04-01
SLG445-ER-0900-04-01
Ürün tip tanımı: SLG445-E/R(1)-01 |
(1) | |
0500-02 | En uç huzmeler arasındaki mesafe 500mm, 2-ışın |
0800-03 | En uç huzmeler arasındaki mesafe 800mm, 3-ışın |
0900-04 | En uç huzmeler arasındaki mesafe 900mm, 4-ışın |
- Safety type 4 in accordance with IEC 61496-1
- User-friendly parameter setting, no tools required
- Reliable safety concept in case of interferences (EMC, welding sparks)
- Process safety with highest availability
- active integrated set-up tool
- Multifunctional
Ordering data
Product type description |
SLG445-ER-0900-04-01 |
Article number (order number) |
103005426 |
EAN (European Article Number) |
4030661436401 |
eCl@ss number, version 12.0 |
27-27-27-03 |
eCl@ss number, version 11.0 |
27-27-27-03 |
eCl@ss number, version 9.0 |
27-27-27-03 |
ETIM number, version 7.0 |
EC001832 |
ETIM number, version 6.0 |
EC001832 |
Approvals - Standards
Certificates |
TÜV cULus |
General data
Standards |
CLC/TS 61496-2 EN IEC 61496-2 EN IEC 61496-1 |
Note (Software Version) |
as of 2024 Version 1.0 |
Housing material |
Aluminyum |
Reaction time, maximum |
10 ms |
Gross weight |
1.580 g |
Bluetooth transmission power, maximum |
2 |
Bluetooth transmission frequency |
2.400 … 2.483 GHz |
Radiation emission level to EN 12198-1 |
Category 0 |
Risk group classification of lamp systems to EN 62471 |
free group |
General data - Features
Muting function |
Evet |
Override |
Evet |
Clock control possible |
Evet |
Restart interlock (manual reset) |
Evet |
Beam coding available |
Evet |
7-segment display |
Evet |
Integral system diagnostics, status |
Evet |
Integral system diagnostics |
Evet |
Number of fail-safe digital outputs |
2 |
Number of beams |
4 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 62061 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
5,14 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Safety type in accordance with IEC 61496-1 |
4 |
Mechanical data
Detection ability for test bodies at v = 1.6 m/s |
300 mm |
Height of the protection field |
900 mm |
Range, protection field, minimum |
0,3 m |
Range, protection field, maximum |
12 m |
Note |
Reduction in range by 10% at an ambient temperature of -25°C |
Wave length of the laserdiode |
880 nm |
Mechanical data - Connection technique
Length of cable |
100 m |
Termination |
Konektör |
Terminal connector, Recipient |
Konektör fişi M12 12-kutup |
Terminal, Connector, Transmitter |
Konektör fişi M12 4-kutup |
Terminal (mechanical) |
with metal thread |
Mechanical data - Dimensions
Length of sensor |
33 mm |
Width of sensor |
27,8 mm |
Height of the Sensor (Receiver) |
1.021 mm |
Height of the Sensor (Transmitter) |
1.011 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-25 ... +50 °C |
Storage and transport temperature |
-25 ... +70 °C |
Resistance to vibrations |
10 … 55 Hz |
Restistance to shock |
10 g, 16 ms, to EN 60028-2-29 |
Protection class |
III |
Electrical data
Rated operating voltage |
24 VDC |
|
Electrical power consumption of the receiver, maximum |
10 W |
|
Electrical power consumption of the transmitter, maximum |
5 W |
|
Length of cable, maximum |
100 m |
|
Rated operating current, Emitter |
200 mA |
|
|
700 mA |
Electrical data - Power supply external devices
Designation, Power supply |
ML |
Rated operating voltage |
24 VDC |
Rated operating current |
250 mA |
Electrical data - Safety digital outputs
Designation, Safety outputs |
OSSD 1 and OSSD 2 |
Output current, (fail-safe output), maximum |
0,25 A |
Design of control elements |
OSSD, short-circuit proof, p-type |
Leakage current Ir, maximum |
1 mA |
Test pulse interval, typical |
750 ms |
Test pulse duration, maximum |
0,1 ms |
Classification ZVEI CB24I, Source |
C3 |
Classification ZVEI CB24I, Sink |
C1 C2 C3 |
Load capacity, maximum |
2,2 µF |
Load inductance, maximum |
2 |
Note |
The load inductance generates an induced voltage during the switch-off, which compromises the downstream components (sparkquenching element). |
Switching voltage |
15 … 26.4 V (HIGH) 0 … 2 V (LOW) |
Note |
According to EN 61131-2 |
Note |
In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
Conduction resistance, maximum |
2,5 Ω |
LED status display - LED 01
LED status |
OSSD ON, OSSD OFF, restart, signal reception, blanking, information |
LED position |
Receiver |
LED status display - LED 02
LED status |
transmitting and status |
LED position |
Emitter |
Other data
Note (applications) |
Automatic operation, restart inhibit, double confirmation, contactor control, object blanking (non-changeable position and changeable position), alternative beam coding, muting, cycle, multiple sampling |
Pin assignment
Connection |
Receiver |
PIN 1 |
24 VDC power supply |
PIN 2 |
0 VDC power supply |
PIN 3 |
Release S1 Input Release S1 |
PIN 4 |
OSSD 1 Safety output 1 |
PIN 5 |
D_OUT Operating Mode |
PIN 6 |
OSSD 2 Safety output 2 |
PIN 7 |
Muting operation: ML Muting lamp |
PIN 8 |
Input Release S2 |
PIN 9 |
Muting operation: D_IN Input EDM, belt-stop, muting enable |
PIN 10 |
Muting operation: MSG 2 Switching input muting sensor group MSG 2 |
PIN 11 |
Not used |
PIN 12 |
Muting operation: MSG 1 Switching input muting sensor group MSG 1 |
Connection |
Emitter |
PIN 1 |
24 VDC power supply |
PIN 2 |
COD1 Coding 1 |
PIN 3 |
0 VDC power supply |
PIN 4 |
COD2 Coding 2 |
Scope of delivery
Scope of delivery |
2 montaj dirsekli set |
Accessory
Recommended safety switchgear |
SRB-E 301 |
Note
Note (General) |
Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |
Dil filtresi
Veri sayfası
Çalışma Talimatları ile Uygunluk beyanı
BG-test sertifikası
UL Sertifikası
SISTEMA-VDMA kütüphanesi
Adobe Reader’ın son sürümünü indirin
Ürün resmi (katalog özel fotoğraf)
EU Declaration of Conformity | ![]() |
Original | Safety Control GmbH Am Industriepark 2a 84453 Mühldorf / Inn Germany |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | SLC445 SLG445 |
Type: | See ordering code |
Description of the component: | Safety light curtain / safety light grid |
Relevant Directives: | Machinery Directive | 2006/42/EC |
EMC-Directive | 2014/30/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 61496-1:2013 EN 61496-2:2013 EN ISO 13849-1:2015 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
Notified body for Type Examination: | TÜV NORD CERT GmbH Langemarckstr. 20, 45141 Essen ID n°: 0044 |
EC-Type Examination Certificate: | 44 205 13144604 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Mühldorf, June 10, 2020 |
![]() | ![]() |
Authorised signature Klaus Schuster Managing Director | Authorised signature Christian Spranger Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Veriler ve ayrıntılar dikkatli bir şekilde kontrol edilmişlerdir. Görüntüler orijinalden farklı olabilir. Daha fazla teknik veri kılavuzda bulunabilir. Teknik değişiklikler ve hatalar olabilir.
Udarbejdet d. 22.04.2025 08:07