ZQ 900-22N

Ürün numarası: 131184475

Downloads

TraceParts CAD Verileri
ePLAN Veri
Product type description:

ZQ 900-(1)(2)


(1)
111 NO contact/1 NC contact
131 NO contacts/3 NC contact
222 NO contacts/2 NC contact
022 NC contact
044 NC contact

(2)
withoutwithout emergency-stop button
Nwith emergency-stop button
Bu tip anahtarı doğrultusundaki mümkün olan tüm cihazlar gönderilemez ve/veya teknik bakımdan uygulanamaz.
  • 3 cable entries M 20 x 1.5
  • Metal enclosure
  • one-side operation / wire up to 75 m long
  • Release push button
  • Position indicator
  • Robust design
  • Large wiring compartment
  • Twisting of towing eye not possible
  • External watertight collar
  • wire pull and breakage detection

Ordering data

Product type description

ZQ 900-22N

Article number (order number)

131184475

EAN (European Article Number)

8905236102165

eCl@ss number, version 12.0

27-37-12-01

eCl@ss number, version 11.0

27-37-12-01

eCl@ss number, version 9.0

27-37-12-01

ETIM number, version 7.0

EC002033

ETIM number, version 6.0

EC002033

Approvals - Standards

Certificates

cULus

CCC

General data

Standards

EN ISO 13850

EN IEC 60947-5-1

EN IEC 60947-5-5

Housing material

Metal tabaka, zinkdruckguss

Housing coating material

boyanmış

Material of the housing cover

Plastik, termoplastik

Length of the wire, maximum

75 m

Gross weight

1.400 g

General data - Features

Emergency-Stop button

Evet

Indicator lamp

Hayır

Number of auxiliary contacts

2

Number of safety contacts

2

Safety classification

Vorschriften

EN ISO 13849-1

Mission time

20 Year(s)

Safety classification - Safety outputs

B10D Normally-closed contact (NC)

100.000 Operations

Mechanical data

Mechanical life, minimum

1.000.000 Operations

Mechanical data - Connection technique

Termination

Vida bağlantısı M20 x 1.5

Cable section, minimum

0,75 mm²

Cable section, maximum

2,5 mm²

Note

Kablo kısmı hakkındaki bütün göstergeler iletken yüksüklerini dahil ediyor.

Mechanical data - Dimensions

Length of sensor

97,2 mm

Width of sensor

71,5 mm

Height of the Sensor, minimum

220,3 mm

Height of the Sensor, maximum

236,3 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature

-25 ... +70 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Ambient conditions - Insulation values

Rated insulation voltage Ui

500 V

Rated impulse withstand voltage Uimp

6 kV

Electrical data

Thermal test current

6 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

4 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1 A

Switching element

2 Normalde açık kontakt (NO)/2 normalde kapalı kontakt (NC)

Switching principle

Susta hareketi

Material of the contacts, electrical

AgCdO, kendi kendini temizler, pozitif hareket

Note

Note (General)

For lengths of over 10 m, intermediate wire supports must be installed every 3 to 5 m.

Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature.

As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner.

At 2 m ... 5 m distance intermediate wire supports are required, see accessories