schmersal_s_icon.png

RSS260-D-LSTM12-8-0,25M

Artikelnummer: 103013285

Downloads

ePLAN Data
CADENAS CAD Data
Product type description:

RSS260-(1)-(2)-(3)-(4)-(5)


(1)
withoutStandard coding
I1Individual coding
I2Individual coding, multiple teaching

(2)
DWith diagnostic output
SDWith serial diagnostic function 1)

(3)
withoutStandard version without feedback circuit monitoring EDM (External Device Monitoring)
F0EDM with automatic reset 1)
F1EDM with manual reset 1)

(4)
withoutWithout EMERGENCY STOP
QAcknowledge input error with EMERGENCY STOP 1)

(5)
withoutConnecting cable (lenght in m)
STConnector plug M8, 8-pole
LSTM12-8-0,25MCable 0.25 m long with connector M12, 8-pole
LSTM8-8-0,1MCable 0.1 m long with connector M8, 8-pole
LSTM12-5-0.25MCable 0.25 m long with connector M12, 5-pole

(*)
1)only for versions -ST, -LSTM12-8-0.25M and -LSTM8-8-0.1M
Ikke alle komponent varianter, som er mulige iht. denne produktkode er tilgængelig og/eller teknisk mulig.
  • Simple mounting without additional angle
  • Universal coding with RFID technology
  • Frontal and lateral actuation enabled
  • RFID-technology for needs-based protection against tampering
  • 8- pole cable connector M12
  • Thermoplastic enclosure

Ordering data

Product type description

RSS260-D-LSTM12-8-0,25M

Article number (order number)

103013285

EAN (European Article Number)

4030661500614

eCl@ss number, version 12.0

27-27-46-01

eCl@ss number, version 11.0

27-27-24-03

eCl@ss number, version 9.0

27-27-24-03

ETIM number, version 7.0

EC001829

ETIM number, version 6.0

EC001829

Approvals - Standards

Certificates

TÜV

cULus

FCC

IC

ANATEL

General data

Standards

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Coding

Universel kodning

Coding level according to EN ISO 14119

lav

Working principle

RFID

Frequency band RFID

125 kHz

Transmitter output RFID, maximum

-6 dB/m

Housing construction form

Blok

Installation conditions (mechanical)

ingen planmontering

Sensor topology

Føler til serier forbindelse

Housing material

Kunststof, Termoplast, selvslukkende

Active area

Plastik, Thermoplastik

Reaction time, maximum

100 ms

Duration of risk, maximum

200 ms

Reaction time, switching off safety outputs via actuator, maximum

100 ms

Gross weight

77 g

General data - Features

Diagnostic output

Ja

Short circuit detection

Ja

Cross-circuit detection

Ja

Series-wiring

Ja

Safety functions

Ja

Cascadable

Ja

Integral system diagnostics, status

Ja

Number of LEDs

3

Number of semi-conductor outputs with signaling function

1

Number of poles

8

Number of fail-safe digital outputs

2

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 61508

Performance Level, up to

e

Category

4

PFH value

6,80 x 10⁻¹⁰ /h

PFD value

1,20 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Actuating panels

på siden

forside

Active area

på siden

forside

Mounting

Til montering af sensorerne er normalt 20 mm skruelængde tilstrækkelig. Ved anvendelse af montageplader anbefales 25 mm skruer.

Type of the fixing screws

2x M4

Tightening torque of the fixing screws, maximum

0,8 Nm

Mechanical data - Switching distances

Typical switching distance, frontal

12 mm

Typical switching distance, lateral

9 mm

Assured switching distance "ON", frontal

10 mm

Assured switching distance "OFF", frontal

18 mm

Assured switching distance "ON", lateral

6 mm

Assured switching distance "OFF", lateral

15 mm

Note (Sao)

The specifications of the safety switching distance Sao refer to a temperature range of
-10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.

Note (switching distance)

All switching distances in accordance EN IEC 60947-5-3

Ude af justering Sikkerhedssensoren og aktuatoren tolererer en horisontal og vertikal forskydning i forhold til hinanden. Den mulige forskydning afhænger af afstanden mellem sensoren og aktuatorens aktive flader. Sikkerhedssensoren er koblet aktiv inden for toleranceområdet.

Hysteresis (Switching distance), maximum

2 mm

Repeat accuracy R

0,5 mm

Note (Repeat accuracy R)

Akseludligning: Den lange sideflade tillader en maks. højdeforskydning (X) af sensor og aktuator på 8 mm (f.eks. monteringstolerance, eller hvis beskyttelsesdøren sænkes). Den tværgående forskydning (y) udgør maks. ± 18 mm (se Illustration: Driftsprincip).Mindsteafstand mellem to sensorsystemer 100 mm

Mechanical data - Connection technique

Note (length of the sensor chain)

Cable length and cross-section change the voltage drop dependiing on the output current

Note (series-wiring)

Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Termination

Forbindelse M12, 8-polet, A-kodet

Mechanical data - Dimensions

Length of sensor

29,5 mm

Width of sensor

39,2 mm

Height of sensor

18 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature

-28 ... +65 °C

Storage and transport temperature

-28 ... +85 °C

Relative humidity, maximum

93 %

Note (Relative humidity)

ikke kondenserende

ingen overisning

Resistance to vibrations

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Permissible installation altitude above sea level, maximum

2.000 m

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0,8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 %

Operating current, minimum

0,5 mA

No-load supply current I0, typical

35 mA

Rated operating voltage

24 VDC

Operating current

600 mA

Required rated short-circuit current

100 A

Time to readiness, maximum

2.000 ms

Switching frequency, maximum

1 Hz

Utilisation category DC-12

24 VDC / 0,05 A

Electrical fuse rating, maximum

2 A

Electrical data - Safety digital inputs

Designation, Safety inputs

X1 and X2

Current consumption of the safety inputs

5 mA

Test pulse duration, maximum

1 ms

Test pulse interval, minimum

100 ms

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital outputs

Designation, Safety outputs

Y1 og Y2

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0,25 A

Design of control elements

kortslutningssikker, P-type

Voltage drop Ud, maximum

1 V

Leakage current Ir, maximum

0,5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,25 A

Test pulse interval, typical

1000 ms

Test pulse duration, maximum

1 ms

Classification ZVEI CB24I, Source

C2

Classification ZVEI CB24I, Sink

C1

C2

Electrical data - Diagnostic outputs

Designation, Diagnostic outputs

OUT

Operating current

50 mA

Voltage drop Ud, maximum

2 V

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,05 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,05 A

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

Status indication

Note (LED switching conditions display)

gul LED: Driftstilstand

grøn LED: Forsyningsspænding

rødt LED : Fejl

Pin assignment

PIN 1

A1 Forsyningsspænding UB

PIN 2

X1 Sikkerhedsindgang 1

PIN 3

A2 GND

PIN 4

Y1 Sikkerhedsudgange 1

PIN 5

OUT Diagnoseudgang

PIN 6

X2 Sikkerhedsindgang 2

PIN 7

Y2 Sikkerhedsudgange 2

PIN 8

uden funktion

Scope of delivery

Scope of delivery

Actuator must be ordered separately.

Accessory

Recommendation (actuator)

RST16-1

RST-U-2

RST260-1

Recommended safety switchgear

SRB-E-301ST

SRB-E-201LC

Sprog filter

Hent sidste version af Adobe Reader

Video ID: RSS-260-12

RST-U-2 actuator for confined spaces (Vimeo)


Video ID: RSS260-13

Produktinformation RSS260 (Vimeo)


Video ID: RSS-260-01

Basic function (Vimeo)


Video ID: RSS-260-02

Variable mounting options (Vimeo)


Video ID: RSS-260-03

Single device connection (Vimeo)


Video ID: RSS-260-04

Series connection with serial diagnostics (Vimeo)


Video ID: RSS-260-05

Cross-fault with controlled shut-down process (Vimeo)


Video ID: RSS-260-06

Tolerance to misalignment (Vimeo)


Video ID: RSS-260-07

Warning when actuator is in limit range (Vimeo)


Video ID: RSS-260-11

RST-16-1 actuator on flat contour safety guards (Vimeo)


EU-overensstemmelseserklæring LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Forklaring:Hermed erklærer vi, at de nedenfor anførte komponenter svarer til de nedenfor anførte europæiske direktiver på basis af deres udførelse og konstruktionstype.
Komponentens betegnelse:RSS260
Type:se typenøgle
Komponentens beskrivelse:Berøringsfri sikkerhedssensor
Relevante direktiver:Maskindirektivet2006/42/EG
 RED-direktivet2014/53/EU
 RoHS-direktivet2011/65/EU
Anvendte standarder:EN 60947-5-3:2013
EN 300 330 V2.1.1:2017
EN ISO 14119:2013
EN ISO 13849-1:2023
EN 61508 del 1-7: 2010
Typegodkendelsesinstitut:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
Identifikations-nr.: 0035
EF-typegodkendelsescertifikat:01/205/5348.04/25
Befuldmægtiget til sammenstilling af den tekniske dokumentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Sted og dato for udstedelsen:Wuppertal, 9. januar 2025
 GRA_SIG_ksig-y24
 Forpligtende underskrift
Philip Schmersal
Direktør
UK Declaration of Conformity LOG_COM_lo1de01s
Company:K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom.
Name of the component:RSS260
Type:See ordering code
Description of the component:Non-contact safety sensor
Relevant legislation:Supply of Machinery (Safety) Regulations2008
 Radio Equipment Regulations2017
 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations2012
Designated standards:



EN 60947-5-3:2013
EN 300 330 V2.1.1:2017
EN ISO 14119:2013
EN ISO 13849-1:2015
IEC 61508 parts 1-7:2010
Approved body for Type Examination:TÜV Rheinland UK Ltd.
1011 Stratford Road
Solihull, B90 4BN
ID: 2571
Type examination certificate:01/205U/5348.00/22
UK-Importer /
Person authorised for the compilation of the technical documentation:



Schmersal UK Ltd.
Paul Kenney
Unit 1, Sparrowhawk Close
Enigma Business Park
Malvern, Worcestershire, WR14 1GL
Place and date of issue:Wuppertal, November 2, 2022
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

De nævnte data og angivelser er blevet checket omhyggeligt. Billeder kan afvige fra originalen. Der kan findes flere tekniske data i manualen. Der tages forbehold for tekniske ændringer og fejl.

Udarbejdet d. 28.04.2025 02.01