schmersal_s_icon.png

SD-I-DP-V0-2 PROFIBUS-GATEWAY

Item number: 101192805

Downloads

TraceParts CAD Data
ePLAN Data
CADENAS CAD Data
SISTEMA Data
  • PROFIBUS Gateway SD-I-DP-V0-2 to convert serial diagnostic signals to the PROFIBUS DP protocol
  • The PROFIBUS Gateway SD-I-DP-V0-2 is a PROFIBUS slave
  • Protection class IP 10 device for control cabinet mounting, for standard DIN rails

Ordering data

Product type description

SD-I-DP-V0-2 PROFIBUS-GATEWAY

Article number (order number)

101192805

EAN (European Article Number)

4030661353951

eCl@ss number, version 12.0

27-23-02-06

eCl@ss number, version 11.0

27-23-02-06

eCl@ss number, version 9.0

27-23-02-08

ETIM number, version 7.0

EC001099

ETIM number, version 6.0

EC001099

General data

Gross weight

120 g

General data - Features

Integral system diagnostics, status

Yes

Number of LEDs

4

Mechanical data

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Termination

Cage clamps

Mechanical data - Dimensions

Width

50 mm

Height

72 mm

Depth

97 mm

Ambient conditions

Degree of protection of the enclosure

IP10

Ambient temperature

-5 ... +55 °C

Storage and transport temperature

-25 ... +85 °C

Resistance to vibrations

5 ... 9 Hz, Amplitude 3.5 mm

9 ... 150 Hz, with 1 g

Restistance to shock

15 g / 11 ms

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 V

Rated impulse withstand voltage Uimp

0.5 kV

Overvoltage category

II

Degree of pollution

2

Electrical data

Operating voltage

24 VDC -15 % / +20 % (stabilised PELV power supply)

Rated operating voltage

24 VDC

Operating current

250 mA

Status indication

Note (LED switching conditions display)

ON permanent light green: supply voltage present

PB Flashing signal: PROFIBUS initialisation

PB Permanent light red: PROFIBUS error

SD Flashing signal: = SD gateway initialisation

SD Permanent light Red: = SD Gateway fault

Other data

Note (applications)

Safety sensor

Guard system

Note

Note (General)

Detailed functions, see programming and configuration manual of the SD Gateway

Wiring example

Note (Wiring diagram)

Serial diagnostics of series-wired safety sensors/solenoid interlocks

Devices with serial diagnostic option: AZ 200, AZM 200, CSS 30S, CSS 34, MZM 100

Video ID: SD-Interface-Mr-Safety

ID: SD-Interface-Mr-Safety

| 75.0 MB | .mp4

| 70.0 MB | .mp4


Schmersal Ltd., Sparrowhawk Close, WR14 1GL Malvern

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 30/11/2024, 21:16