SD-I-DP-V0-2 PROFIBUS-GATEWAY
SD-I-DP-V0-2 PROFIBUS-GATEWAY
Downloads
- PROFIBUS Gateway SD-I-DP-V0-2 to convert serial diagnostic signals to the PROFIBUS DP protocol
- The PROFIBUS Gateway SD-I-DP-V0-2 is a PROFIBUS slave
- Protection class IP 10 device for control cabinet mounting, for standard DIN rails
Ordering data
Product type description |
SD-I-DP-V0-2 PROFIBUS-GATEWAY |
Article number (order number) |
101192805 |
EAN (European Article Number) |
4030661353951 |
eCl@ss number, version 12.0 |
27-23-02-06 |
eCl@ss number, version 11.0 |
27-23-02-06 |
eCl@ss number, version 9.0 |
27-23-02-08 |
ETIM number, version 7.0 |
EC001099 |
ETIM number, version 6.0 |
EC001099 |
General data
Gross weight |
120 g |
General data - Features
Integral system diagnostics, status |
Yes |
Number of LEDs |
4 |
Mechanical data
Mounting |
Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique
Termination |
Cage clamps |
Mechanical data - Dimensions
Width |
50 mm |
Height |
72 mm |
Depth |
97 mm |
Ambient conditions
Degree of protection of the enclosure |
IP10 |
Ambient temperature |
-5 ... +55 °C |
Storage and transport temperature |
-25 ... +85 °C |
Resistance to vibrations |
5 ... 9 Hz, Amplitude 3.5 mm 9 ... 150 Hz, with 1 g |
Restistance to shock |
15 g / 11 ms |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 V |
Rated impulse withstand voltage Uimp |
0.5 kV |
Overvoltage category |
II |
Degree of pollution |
2 |
Electrical data
Operating voltage |
24 VDC -15 % / +20 % (stabilised PELV power supply) |
Rated operating voltage |
24 VDC |
Operating current |
250 mA |
Status indication
Note (LED switching conditions display) |
ON permanent light green: supply voltage present PB Flashing signal: PROFIBUS initialisation PB Permanent light red: PROFIBUS error SD Flashing signal: = SD gateway initialisation SD Permanent light Red: = SD Gateway fault |
Other data
Note (applications) |
Safety sensor Guard system |
Note
Note (General) |
Detailed functions, see programming and configuration manual of the SD Gateway |
Wiring example
Note (Wiring diagram) |
Serial diagnostics of series-wired safety sensors/solenoid interlocks Devices with serial diagnostic option: AZ 200, AZM 200, CSS 30S, CSS 34, MZM 100 |
Language filter
Datasheet
Mounting and wiring instructions
EC Declaration of conformity
Wiring example (electr. wiring)
Brochure
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Wiring example
Video ID: SD-Interface-Mr-Safety
Schmersal Ltd., Sparrowhawk Close, WR14 1GL Malvern
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.