SLG240COM-ER-0500-02
SLG240COM-ER-0500-02
Product type description: SLG240COM-ER-(1) |
(1) | |
0500-02 | Distance between outermost beams 500 mm, 2-beam |
0800-03 | Distance between outermost beams 800 mm, 3-beam |
0900-04 | Distance between outermost beams 900 mm, 4-beam |
- Safety type 2 in accordance with IEC 61496-1
- User-friendly parameter setting, no tools required
- Reliable safety concept in case of interferences (EMC, welding sparks)
- Process safety with highest availability
- active integrated set-up tool
Ordering data
Product type description |
SLG240COM-ER-0500-02 |
Article number (order number) |
103016120 |
EAN (European Article Number) |
4030661506531 |
eCl@ss number, version 12.0 |
27-27-27-03 |
eCl@ss number, version 11.0 |
27-27-27-03 |
eCl@ss number, version 9.0 |
27-27-27-03 |
ETIM number, version 7.0 |
EC001832 |
ETIM number, version 6.0 |
EC001832 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN IEC 61496-2 EN IEC 61496-1 |
Note (Software Version) |
as of 2017 Version 1.0 |
Master- or Slave-function |
Yes |
Housing material |
Aluminium |
Reaction time, maximum |
10 ms |
Gross weight |
940 g |
Radiation emission level to EN 12198-1 |
Category 0 |
Risk group classification of lamp systems to EN 62471 |
free group |
General data - Features
Cascadable |
Yes |
Restart interlock (manual reset) |
Yes |
Blanking function |
Yes |
Integral system diagnostics, status |
Yes |
Integral system diagnostics |
Yes |
Number of fail-safe digital outputs |
2 |
Number of beams |
2 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 62061 |
Performance Level, up to |
c |
Category |
2 |
PFH value |
8.05 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
1 |
Mission time |
20 Year(s) |
Safety type in accordance with IEC 61496-1 |
2 |
Mechanical data
Detection ability for test bodies at v = 1.6 m/s |
500 mm |
Height of the protection field |
500 mm |
Range, protection field, minimum |
0.3 m |
Range, protection field, maximum |
12 m |
Wave length of the laserdiode |
880 nm |
Mechanical data - Connection technique
Length of cable |
100 m |
Termination |
Connector |
Terminal connector, Recipient |
Connector plug M12, 5-pole |
Terminal, Connector, Transmitter |
Connector plug M12, 4-pole |
Mechanical data - Dimensions
Length of sensor |
33 mm |
Width of sensor |
27.8 mm |
Height of sensor |
571 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-10 ... +50 °C |
Storage and transport temperature |
-25 ... +70 °C |
Resistance to vibrations |
10 … 55 Hz |
Restistance to shock |
10 g, 16 ms, to EN 60028-2-29 |
Protection class |
III |
Electrical data
Operating voltage |
24 VDC -10 % / +10 % ((PELV) supply unit Imax 1.0 A, according to EN 60204 (power failure ≤ 20 ms)) |
|
Rated operating voltage |
24 VDC |
|
Rated operating current, Emitter |
200 mA |
|
|
700 mA |
Electrical data - Control inputs
Switching thresholds |
24 V (HIGH) 0 V (LOW) |
Electrical data - Control inputs
Designation, Control inputs |
Reset and Test |
Actuation time for manual start |
100 … 1500 ms |
Electrical data - Safety digital outputs
Designation, Safety outputs |
OSSD 1 and OSSD 2 |
Output current, (fail-safe output), maximum |
0.25 A |
Design of control elements |
OSSD, short-circuit proof, p-type |
Leakage current Ir, maximum |
1 mA |
Test pulse interval, typical |
750 ms |
Test pulse duration, maximum |
0.15 ms |
Classification ZVEI CB24I, Source |
C2 |
Classification ZVEI CB24I, Sink |
C1 C2 |
Load capacity, maximum |
0.05 µF |
Load inductance, maximum |
2 H |
Note |
The load inductance generates an induced voltage during the switch-off, which compromises the downstream components (sparkquenching element). |
Switching voltage |
15 … 26.4 V (HIGH) 0 … 2 V (LOW) |
Note |
According to EN 61131-2 |
Note |
In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
LED status display - LED 01
LED status |
OSSD ON, OSSD OFF, Restart interlock, Error, Parameter setting, Alignment kit, Indication of signal quality |
LED position |
Receiver |
Pin assignment
Connection |
Receiver |
PIN 1 |
24 VDC power supply |
PIN 2 |
OSSD 1 Safety output 1 |
PIN 3 |
0 VDC Power supply |
PIN 4 |
OSSD 2 Safety output 2 |
PIN 5 |
Reset Restart interlock (manual reset) |
Connection |
Emitter |
PIN 1 |
24 VDC power supply |
PIN 2 |
Test Test input |
PIN 3 |
0 VDC power supply |
PIN 4 |
Slave Series wiring |
Scope of delivery
Scope of delivery |
Kit with 2 mounting angles |
Accessory
Recommended safety switchgear |
SRB-E 301 |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
Brochure
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Contact arrangement
Contact arrangement
Wiring example
Schmersal Ltd., Sparrowhawk Close, WR14 1GL Malvern
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 08/05/2025, 12:20