schmersal_s_icon.png

T2S 015-02Y

Item number: 131054855

Downloads

TraceParts CAD Data
ePLAN Data
CADENAS CAD Data
SISTEMA Data
Product type description:

(1)(2) 015-(3)Y-(4)


(1)
TSlow action (not for AF/S)
MSnap action

(2)
SPlunger S
2STelescopic plunger 2S
KOffset roller lever K
2KTilt lever 2K
3KAngle roller lever 3K
8HRoller lever 8H
7HRoller lever 7H
10HRod lever 10H
HRoller lever H
4HSpring rod lever on shaft 4H
2HLeaf spring lever 2H
3HRoller lever 3H
9HRod lever 9H
6HLeaf spring lever 6H

(3)
111 NO contact/1 NC contact
022 NC contact
202 NO contacts

(4)
UESlow action with overlapping contacts
HSlow action with staggered contacts
CMagnetic blow-out
Not all component variants, which are possible according to this order code are available and/or technically feasible.
  • Metal enclosure
  • 2 Contacts
  • 67 mm x 75 mm x 43 mm ( basic component)
  • With large after-travel
  • Actuator head with captive stainless steel ball actuator

Ordering data

Product type description

T2S 015-02Y

Article number (order number)

131054855

EAN (European Article Number)

8905236107474

eCl@ss number, version 12.0

27-27-06-01

eCl@ss number, version 11.0

27-27-06-01

eCl@ss number, version 9.0

27-27-06-01

ETIM number, version 7.0

EC000030

ETIM number, version 6.0

EC000030

Approvals - Standards

Certificates

CCC

General data

Standards

EN IEC 60947-5-1

Working principle

mechanical

Slide form

Sphere

Housing material

Light-alloy diecast, paint finish

Housing coating material

painted

Gross weight

329 g

Mechanical data

Actuating element

Plunger

Actuating angle

20 °

Actuating speed, minimum

1 mm/min

Actuating speed, maximum

1 m/s

Note (Actuating speed)

Actuating speed with vertical actuating angle to switch axis

Mechanical data - Dimensions

Length of sensor

43 mm

Width of sensor

67 mm

Height of sensor

130 mm

Diameter of the Plunger

10 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature

-30 ... +90 °C

Electrical data

Thermal test current

10 A

Material of the contacts, electrical

Silver

Note

Note (General)

Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch.

EU Conformity Declaration
EU Declaration of Conformity LOG_COM_lo1de01s
OriginalSchmersal India Private Limited
G-7/1, MIDC, Ranjangaon
Tal. Shirur, Dist. Pune – 412 220
Maharashtra
India
Internet: www.schmersal.in
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:T/M 015
T 016
T/M 017
Type:See ordering code
Description of the component:Limit switches
Relevant Directives:Low Voltage Directive2014/35/EU
 RoHS-Directive2011/65/EU
Applied standards:EN 60947-5-1:2004 + AC:2005 + A1:2009
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Pune, January 15, 2020
  GRA_SIG_ksig-y36
 Authorised signature
Sagar Jeevan Bhosale
Managing Director

Schmersal Ltd., Sparrowhawk Close, WR14 1GL Malvern

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 01/12/2024, 06:34