EX-AZM300Z-I2-ST-1P2P-A-CL-3GD
EX-AZM300Z-I2-ST-1P2P-A-CL-3GD
Produkt-typebetegnelse: EX-AZM300(1)(2)-ST(3)(4)(5) |
(1) | |
Z | Vernelås overvåket > |
B | Aktivator overvåket |
(2) | |
uten | Standard koding |
I1 | Individuelt kodet |
I2 | Individuelt kodet, multippel innlæring |
(3) | |
1P2P | 1 diagnoseutgang, p-type og 2 sikkerhetsutganger, p-type |
SD2P | Seriell diagnoseutgang og 2 sikkerhetsutganger, p-type |
(4) | |
uten | åpner med spenning |
A | driftsspenning |
(5) | |
CL | Mit Schutzgehäuse, Türanschlag links |
CR | Mit Schutzgehäuse, Türanschlag rechts |
- Explosion protection for ATEX Zones 2 and 22
- RFID-technology for needs-based protection against tampering
- Thermoplastic enclosure
- Suitable for mounting to profile systems
- Suitable for hinged and sliding guards
- Series-wiring
- Manual release
Ordering data
Product type description |
EX-AZM300Z-I2-ST-1P2P-A-CL-3GD |
Article number (order number) |
103052216 |
EAN (European Article Number) |
4030661632858 |
eCl@ss number, version 12.0 |
27-27-26-03 |
eCl@ss number, version 11.0 |
27-27-26-03 |
eCl@ss number, version 9.0 |
27-27-26-03 |
ETIM number, version 7.0 |
EC002593 |
ETIM number, version 6.0 |
EC002593 |
Approvals - Standards
Certificates |
ATEX (Konformitätserklärung) |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN 60079-7 EN 60079-31 |
Explosion protection zones |
2 22 |
Explosion protection category |
3G 3D |
Explosion protection designation |
D II 3G Ex ic IIC T5 Gc X D II 3D Ex tc IIIB T95°C Dc X |
General data
Standards |
EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding |
Individuelt kodet, multippel innlæring |
Coding level according to EN ISO 14119 |
Høy |
Working principle |
RFID |
Frequency band RFID |
125 kHz |
Transmitter output RFID, maximum |
-6 dB/m |
Housing material |
Plast, glassfiber forsterket termoplast, selvslukkende |
Duration of risk, maximum |
200 ms |
Reaction time, switching off safety outputs via actuator, maximum |
100 ms |
Reaction time, switching off safety outputs via safety inputs, maximum |
1,5 ms |
Gross weight |
1 100 g |
General data - Features
Power to lock |
Ja |
Solenoid interlock monitored |
Ja |
Latching |
Ja |
Manual release |
Ja |
Short circuit detection |
Ja |
Cross-circuit detection |
Ja |
Series-wiring |
Ja |
Safety functions |
Ja |
Integral system diagnostics, status |
Ja |
Number of actuating directions |
1 |
Number of fail-safe digital outputs |
2 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 61508 |
Safety classification - Interlocking function
Performance Level, up to |
e |
Category |
4 |
PFH value |
5,20 x 10⁻¹⁰ /h |
PFD value |
4,50 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Safety classification - Guard locking function
Performance Level, up to |
d |
Category |
2 |
PFH value |
2,00 x 10⁻⁹ /h |
PFD value |
1,80 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Mission time |
20 Year(s) |
Mechanical data
Mechanical life, minimum |
1 000 000 Operations |
Note (Mechanical life) |
Ved bruk som dørhengsel > 50 000 bevegelser ved dørmasser ≤ 5 kg; |
Angular misalignment between solenoid interlock and actuator, maximum |
2 ° |
Energy impact (protective case), maximum |
7 J |
Note (Energy impact) |
with stainless steel CL/CR protective enclosure |
Holding force FZh in accordance with EN ISO 14119 |
1 150 N |
Holding force Fmax, maximum |
1 500 N |
Latching force, adjustable, position 1 |
25 N |
Latching force, adjustable, position 2 |
50 N |
Type of the fixing screws |
2x M6 |
Note (Type of the fixing screws) |
Property class min. 8.8 |
Tightening torque of the fixing screws, maximum |
8 Nm |
Material of the fixing screws |
Rustfritt stål (V4A) |
Mechanical data - Switching distances
Switch distance, typical |
2 mm |
Assured switching distance "ON" Sao |
1 mm |
Assured switching distance "OFF" Sar |
20 mm |
Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-3 |
Mechanical data - Connection technique
Length of sensor chain, maximum |
200 m |
Note (length of the sensor chain) |
Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series-wiring) |
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Termination |
Konnektor M12, 8-polet, A-kodet |
Mechanical data - Dimensions
Length of sensor |
178 mm |
Width of sensor |
93 mm |
Height of sensor |
40,3 mm |
Ambient conditions
Degree of protection |
IP66 IP67 IP69 |
Ambient temperature |
+0 ... +50 °C |
Storage and transport temperature |
-10 ... +90 °C |
Relative humidity, maximum |
93 % |
Note (Relative humidity) |
ikke kondenserende ikke-ising |
Resistance to vibrations |
10 … 150 Hz, Amplitude 0,35 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
III |
Permissible installation altitude above sea level, maximum |
2 000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0,8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC -15 % / +10 % |
No-load supply current I0, typical |
100 mA |
Current consumption with magnet ON, average |
200 mA |
Current consumption with magnet ON, peak |
350 mA / 200 ms |
Rated operating voltage |
24 VDC |
Required rated short-circuit current |
100 A |
External wire and device fuse rating |
2 A gG |
Time to readiness, maximum |
5 000 ms |
Switching frequency, maximum |
0,5 Hz |
Utilisation category DC-12 |
24 VDC / 0,05 A |
Electrical fuse rating, maximum |
2 A |
Electrical data - Magnet control
Designation, Magnet control |
IN |
Switching thresholds |
-3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V |
10 mA |
Magnet switch-on time |
100 % |
Test pulse duration, maximum |
5 ms |
Test pulse interval, minimum |
40 ms |
Classification ZVEI CB24I, Sink |
C0 |
Classification ZVEI CB24I, Source |
C1 C2 C3 |
Electrical data - Safety digital inputs
Designation, Safety inputs |
X1 and X2 |
Switching thresholds |
−3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V |
5 mA |
Test pulse duration, maximum |
1 ms |
Test pulse interval, minimum |
100 ms |
Classification ZVEI CB24I, Sink |
C1 |
Classification ZVEI CB24I, Source |
C1 C2 C3 |
Electrical data - Safety digital outputs
Designation, Safety outputs |
Y1 and Y2 |
Design of control elements |
short-circuit proof, p-type |
Voltage drop Ud, maximum |
2 V |
Leakage current Ir, maximum |
0,5 mA |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,25 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,25 A |
Test pulse interval, typical |
1000 ms |
Test pulse duration, maximum |
0,5 ms |
Classification ZVEI CB24I, Source |
C2 |
Classification ZVEI CB24I, Sink |
C1 C2 |
Electrical data - Diagnostic outputs
Designation, Diagnostic outputs |
OUT |
Design of control elements |
short-circuit proof, p-type |
Voltage drop Ud, maximum |
2 V |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,05 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,05 A |
Status indication
Note (LED switching conditions display) |
Koblingsforhold: gul lysdiode Feil funksjonell defekt: rød lysdiode Tilførselsspenning UB: grønn lysdiode |
Pin assignment
PIN 1 |
A1 Matespenning |
PIN 2 |
X1 Sikkerhetsinngang 1 |
PIN 3 |
A2 GND |
PIN 4 |
Y1 Sikkerhetsutgang 1 |
PIN 5 |
OUT DIagnostisk utgang |
PIN 6 |
X2 Sikkerhetsinngang 2 |
PIN 7 |
Y2 Sikkerhetsutgang 2 |
PIN 8 |
IN Solenoidkontroll |
Scope of delivery
Scope of delivery |
Actuator must be ordered separately. |
Accessory
Recommendation (actuator) |
EX-AZ/AZM300-B1 |
Note
Note (General) |
For dører som er i plan med dørkarmen, kan den valgfrie monteringsplaten MP-AZ/AZM300-1 brukes. For glass- og makrolondører kan det valgfrie monteringssettet MS-AZ/AZM300-B1-1 brukes. Så lenge aktueringsenheten forblir satt inn i den magnetiske forriglingen, kan den ulåste sikkerhetsvakten låses på nytt. Sikkerhetsutgangene vil så bli aktivert igjen. Det er derfor ikke nødvendig å åpne vakten. |
Språk filter
Datablad
Bruksanvisning og konformitetserklæring
UKCA Declaration of Conformity
SISTEMA-VDMA Bibliotek/Library
Last ned den nyeste versjonen av Adobe Reader
Produktbilde (enkelt katalogbilde)
Dimensjonsriktig tegning grunnenhet
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Data og verdier er kontrollert omhyggelig. Bilder kan avvike fra originalen. Ytterligere tekniske data finner du i manualen. Tekniske modifiseringer og feil kan forkomme.
Generert til 06.04.2025, 21:42