SLC 421-E/R1370-30-RFBC
SLC 421-E/R1370-30-RFBC
| Product type description: SLC 421-E/R(1)-(2)-RFBC-(3) |
| (1) | |
| 0170 | Protection field height 170 mm |
| 0250 | Protection field height 250 mm |
| 0330 | Protection field height 330 mm |
| 0410 | Protection field height 410 mm |
| 0490 | Protection field height 490 mm |
| 0570 | Protection field height 570 mm |
| 0650 | Protection field height 650 mm |
| 0730 | Protection field height 730 mm |
| 0810 | Protection field height 810 mm |
| 0890 | Protection field height 890 mm |
| 0970 | Protection field height 970 mm |
| 1050 | Protection field height 1050 mm |
| 1130 | Protection field height 1130 mm |
| 1210 | Protection field height 1210 mm |
| 1290 | Protection field height 1290 mm |
| 1370 | Protection field height 1370 mm |
| 1450 | Protection field height 1450 mm |
| 1530 | Protection field height 1530 mm (only for resolution 30 mm, 50 mm) |
| 1610 | Protection field height 1610 mm (only for resolution 30 mm, 50 mm) |
| 1690 | Protection field height 1690 mm (only for resolution 30 mm, 50 mm) |
| 1770 | Protection field height 1770 mm (only for resolution 30 mm, 50 mm) |
| (2) | |
| 14 | Resolution 14 mm |
| 30 | Resolution 30 mm |
| (3) | |
| 01 | integrated status display |
- Protection class IP67
- Safety type 4 in accordance with IEC 61496-1
- Parameter assignment using external command devices
- Resolution 14 and 30 mm
Ordering data
| Note (Delivery capacity) |
Not available! |
| Product type description |
SLC 421-E/R1370-30-RFBC |
| Article number (order number) |
101212675 |
| EAN (European Article Number) |
4030661396941 |
| eCl@ss number, version 12.0 |
27-27-27-04 |
| eCl@ss number, version 11.0 |
27-27-27-04 |
| eCl@ss number, version 9.0 |
27-27-27-04 |
| ETIM number, version 7.0 |
EC002549 |
| ETIM number, version 6.0 |
EC002549 |
Approvals - Standards
| Certificates |
cULus |
General data
| Standards |
EN IEC 61496-2 EN IEC 61496-1 |
| Housing material |
Aluminium |
| Reaction time, maximum |
25 ms |
| Gross weight |
5,720 g |
General data - Features
| Clock control possible |
Yes |
| Restart interlock (manual reset) |
Yes |
| Contactor control integrated |
Yes |
| Beam coding available |
Yes |
| Blanking function |
Yes |
| Integral system diagnostics, status |
Yes |
| Integral system diagnostics |
Yes |
| Number of fail-safe digital outputs |
2 |
| Number of beams |
68 |
| Safety classification |
| Standards |
EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
| Performance Level, up to |
e |
| Category |
4 |
| PFH value |
7.42 x 10⁻⁹ /h |
| Safety Integrity Level (SIL), suitable for applications in |
3 |
| Mission time |
20 Year(s) |
| Safety type in accordance with IEC 61496-1 |
4 |
Mechanical data
| Detection ability for test bodies at v = 1.6 m/s |
30 mm |
| Height of the protection field |
1,370 mm |
| Range, protection field, minimum |
0.3 m |
| Range, protection field, maximum |
7 m |
| Wave length of the laserdiode |
880 nm |
Mechanical data - Connection technique
| Termination |
Connector |
| Terminal connector, Recipient |
Connector plug M12, 12-pole |
| Terminal, Connector, Transmitter |
Connector plug M12, 4-pole |
| Length of the connectable cable, maximum |
100 m |
Mechanical data - Dimensions
| Diameter of sensor |
49 mm |
| Height of sensor |
1,588 mm |
Ambient conditions
| Degree of protection |
IP67 |
| Ambient temperature |
-10 ... +50 °C |
| Storage and transport temperature |
-20 ... +70 °C |
| Protection class |
III |
Electrical data
| Switching voltage OSSD, HIGH signal |
24 V |
| Electrical power consumption of the receiver |
8 W |
| Electrical power consumption of the transmitter |
4 W |
| Wiring / Connector of external control unit |
Connector plug M8, 6-pole |
Electrical data - Safety digital outputs
| Output current, (fail-safe output), maximum |
0.5 A |
| Design of control elements |
p-type |
Scope of delivery
| Scope of delivery |
Emitter + receiver, mounting angle |
Accessory
| Recommended safety switchgear |
SCR 211 |
Note
| Note (General) |
Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |
| Note (Clock control) |
1 cycle or 2 cycles |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
Brochure
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Operating principle
Contact arrangement
Contact arrangement
Contact arrangement
Schmersal Ltd., Sparrowhawk Close, WR14 1GL Malvern
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.