BN 120L-10Z/V 2,0M
BN 120L-10Z/V 2,0M
Downloads
- Actuation from front
- with bias magnet
- Non-contact principle
- Long life
- Thermoplastic enclosure
- Actuating distance up to 60 mm depending on actuating magnet and version
- Design Ø 10.7 mm
- with central mounting
- With pre-wired cable
Ordering data
Note (Delivery capacity) |
Phased-out product |
Product type description |
BN 120L-10Z/V 2,0M |
Article number (order number) |
101210880 |
EAN (European Article Number) |
4030661388472 |
eCl@ss number, version 12.0 |
27-27-43-02 |
eCl@ss number, version 11.0 |
27-27-01-05 |
eCl@ss number, version 9.0 |
27-27-01-05 |
ETIM number, version 7.0 |
EC002544 |
ETIM number, version 6.0 |
EC002544 |
General data
Working principle |
Magnetic drive |
Housing construction form |
Cylinder, thread |
Housing material |
Glass-fibre, reinforced thermoplastic |
Gross weight |
56 g |
General data - Features
Suitable for elevators |
Yes |
bias magnet |
Yes |
Number of normally open (NO) |
1 |
Mechanical data
Actuating panels |
front side |
Actuating element |
Magnet |
Mechanical life, minimum |
10,000,000 Operations |
Mounting |
central with threated flange M12 x 1 |
Tightening torque of nuts, maximum |
0.9 Nm |
Mechanical data - Switching distances according EN IEC 60947-5-3
Switching distance Sn |
5 mm … 55 mm BP 10S = 5 mm 2 x BP 10S = 10 mm BP 15S = 6 mm BP 34S = 20 mm BP 20S = 15 mm BP 31S = 15 mm BP 11S = 5 mm 2 x BP 11S = 15 mm BP 12S = 10 mm 2 x BP 12S = 25 mm BP 21S = 30 mm 2 x BP 21S = 20 ... 55 mm BP 22S = 25 mm 2 x BP 22S = 15 ... 55 mm BE 20 S = 6 mm |
Note (Switching distance Sn) |
Actuating distance up to 55 mm depending on actuating magnet and version. The specified switching distances are applicable for the actuation of individually mounted components without ferromagnetic influence. A change of the distance, either positive or negative, is possible due to ferromagnetic influences. The mutual interference between multiple actuating magnets must be observed. |
Repeat accuracy R |
0.3 mm |
Mechanical data - Connection technique
Length of cable |
2 m |
Termination |
Cable |
Wire cross-section |
0.25 mm2 |
Wire cross-section |
23 AWG |
Material of the Cable mantle |
LiYY |
Mechanical data - Dimensions
Diameter of sensor |
10.7 mm |
width across flats |
17 BK |
Length of sensor |
102 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-25 ... +70 °C |
Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
Restistance to shock |
30 g / 11 ms |
Electrical data
Switching voltage, maximum |
200 VAC |
Switching voltage, maximum |
200 VDC |
Switching current, maximum |
1 A |
Switching capacity, maximum |
30 W |
Switching capacity, maximum |
30 VA |
Switching element |
Normally open contact (NO) |
Electrical data - Digital Output
Design of control elements |
Reed contacts |
Scope of delivery
Scope of delivery |
Actuator must be ordered separately. |
Accessory
Recommendation (actuator) |
BP 10 S 2x BP 10 S BP 15 S BP 34 S BP 20 S BP 31 S BP 11 S 2x BP 11 S BP 12 S 2x BP 12S BP 21 S 2x BP 21 S BP 22 S 2x BP 22 S BE 20 S |
Recommendation (actuator, lift switchgear) |
BP 10 2 x BP 10 BP 15 BP 34 |
Note
Note (General) |
The opening and closing functions depend on the direction of actuation, the actuating magnets and the polarity of the actuating magnets. When the switches and actuators come together, the colours must coincide: Red (S) to red (S) and green (N) to green (N). This does not apply to the bistable contact. The switch is to be mounted on iron with a non-magnetic layer of at least 20 mm. |
Language filter
Datasheet
Mounting and wiring instructions
EC Declaration of conformity
Info
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Switch travel diagram
Diagram
Characteristic curve
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 18/12/2024, 9:24 am