EX-BNS 250-11Z-3GD 6,5M
EX-BNS 250-11Z-3GD 6,5M
Désignation produit: EX-BNS 250-(1)Z(2)-(3)3G/D |
(1) | |
11 | 1 contact NO / 1 contact NF |
12 | 1 contact NO / 2 contacts NF |
(2) | |
Sans | Sans indication d'état par LED |
G | Avec indication d'état par LED |
(3) | |
2187 | Contacts connectés individuellement (sans indication d'état par LED) |
- Protection antidéflagrante pour les zones ATEX 2 et 22
- Boîtier plastique
- Permet un jeu mécanique
- pas d"usure mécanique
- 64 mm x 29,5 mm x 15,5 mm (y compris boîtier de protection)
Exemple de commande
Désignation de type du produit |
EX-BNS 250-11Z-3GD 6,5M |
Référence d’article (n° de commande) |
103045520 |
EAN (European Article Number) |
4030661565088 |
eCl@ss number, version 12.0 |
27-27-44-01 |
eCl@ss number, version 11.0 |
27-27-24-02 |
Numéro eCl@ss, version 9.0 |
27-27-24-02 |
ETIM number, version 7.0 |
EC002544 |
ETIM number, version 6.0 |
EC002544 |
Protection antidéflagrante
Protection antidéflagrante: Normes de référence |
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31 |
Zones de protection antidéflagrante |
2 22 |
Catégorie de protection antidéflagrante |
3G 3D |
Etiquetage protection antidéflagrante |
D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
Déclaration du constructeur |
ATEX Zone 2 et 22 |
Caractéristiques globales
Modèle de boîtier |
Bloc |
Conditions de montage (mécaniques) |
non affleuré |
Matériau du boîtier |
Plastique, thermoplastique renforcé de fibres de verre |
Poids brut |
190 g |
Données générales - Caractéristiques
Codage |
Oui |
Condition préalable Unité d’évaluation |
Oui |
Nombre de contacts NF |
1 |
Nombre de contacts NO |
1 |
Nombre de conducteurs de câble |
4 |
Classification
Normes de référence |
EN ISO 13849-1 |
Durée d'utilisation |
20 année(s) |
Classification de sécurité - Sorties de sécurité
Valeur B10D, contact NC/NO |
25 000 000 manœuvres |
Données mécaniques
Actionneur |
Aimant |
Energie d'impact, max. |
7 J |
Direction de mouvement |
Frontale par rapport à la face active |
Données mécaniques - Distances de commutation selon EN IEC 60947-5-3
Intervalle de commutation protégé MARCHE |
4 mm |
Intervalle de commutation protégé ARRET |
14 mm |
Données mécaniques – technique de connexion
Longueur du câble |
6,5 m |
Connecteur de raccordement |
Câble |
Section des conducteurs |
0,25 mm2 |
Section des conducteurs |
23 AWG |
Matériau de la gaine de câble |
PVC |
Données mécaniques - Dimensions
Longueur du capteur |
13 mm |
Largeur du capteur |
33 mm |
Hauteur du capteur |
25 mm |
Conditions ambiantes
Etanchéité |
IP67 |
Ambient temperature |
-25 ... +70 °C |
Storage and transport temperature |
-25 ... +70 °C |
Tenue aux vibrations selon EN 60068-2-6 |
10…55 Hz, amplitude 1 mm |
Tenue aux chocs mécaniques |
30 g / 11 ms |
Données électriques
Tension commutable, max. |
24 VDC |
Courant commutable, max. |
0,1 A |
Puissance commutable, max. |
1 W |
Elément de commutation |
1 contact NO, 1 contact NF |
Fréquence de commutation, max. |
5 Hz |
Données électriques - Sortie numérique
Exécution |
Autres, contact Reed |
Inclus dans la livraison
Inclus dans la livraison |
Actuator must be ordered separately. |
Accessoires
Recommandation (actionneur) |
EX-BPS 250-3G/D |
Recommandation dispositif de commutation de sécurité |
SRB-E-301ST SRB-E-201LC |
Remarque
Remarque (en général) |
Symboles des contacts, protecteur fermé. La configuration des contacts pour les versions avec ou sans LED est identique. |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Brochure
Bibliothèque/Library SISTEMA-VDMA
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Plan d'encombrement composant de base
Diagramme de contact
Courbe caractéristique
UK Declaration of Conformity |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | EX-BNS 250 | EX-BPS 250 |
Type: | See ordering code |
Marking: | D II 3G Ex nC IIC T6 Gc D II 3D Ex tc IIIC T80°C Dc | D II 3G Ex h IIC T6 Gc D II 3D Ex h IIIC T80°C Dc |
Description of the component: | Coded safety-sensor with magnetic operating principle in combination with the SRB(-E) / PROTECT-SELECT / PSC1 safety-monitoring modules from Schmersal or an equivalent safety-oriented control system fulfilling the requirements of the EN 60947-5-3. |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN 60947-5-3:2013 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 EN ISO 80079-36:2016 EN ISO 80079-37:2016 |
Conformity with SI 2016/1107 (Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations) is declared by the manufacturer without involving a conformity assessment center. |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, November 10, 2022 |
Authorised signature Philip Schmersal Managing Director |
EU Declaration of Conformity |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | EX-BNS 250 | EX-BPS 250 |
Type: | See ordering code |
Marking: | D II 3G Ex nC IIC T6 Gc D II 3D Ex tc IIIC T80°C Dc | D II 3G Ex h IIC T6 Gc D II 3D Ex h IIIC T80°C Dc |
Description of the component: | Coded safety-sensor with magnetic operating principle in combination with the SRB(-E) / PROTECT-SELECT / PSC1 safety-monitoring modules from Schmersal or an equivalent safety-oriented control system fulfilling the requirements of the EN 60947-5-3. |
Relevant Directives: | Machinery Directive | 2006/42/EC |
Explosion Protection Directive (ATEX) | 2014/34/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 60947-5-3:2013 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 EN ISO 80079-36:2016 EN ISO 80079-37:2016 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Conformity with the explosion protection directive 2014/34/EU (ATEX) is declared by the manufacturer without involving a test center. |
Place and date of issue: | Wuppertal, May 10, 2022 |
Authorised signature Philip Schmersal Managing Director |
Schmersal Schweiz AG, Moosmattstraße 3, 8905 Arni
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 23.11.2024 16:51