SFB-EC-8M12-IOP
SFB-EC-8M12-IOP
- Safety fieldbox for EtherCAT with FSoE
- For connection of up to 8 safety switching devices
- Integrated dual-port switch
- Protection class IP66, IP67
Ordering data
Product type description |
SFB-EC-8M12-IOP |
Article number (order number) |
103047531 |
EAN (European Article Number) |
4030661628707 |
eCl@ss number, version 12.0 |
27-24-26-04 |
eCl@ss number, version 11.0 |
27-24-26-04 |
eCl@ss number, version 9.0 |
27-24-26-04 |
ETIM number, version 7.0 |
EC001599 |
ETIM number, version 6.0 |
EC001599 |
Approvals - Standards
Certificates |
TÜV cULus UKCA |
General data
Standards |
EN IEC 61131-1 EN IEC 61131-2 EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
Housing material |
Plastique, polyamide PA 6 GF |
Material of the identification label |
Plastique, polyamide PA |
Material of viewing window |
Polyamide PACM 12 |
Material of electronic encapsulation |
Polyuréthane 2K PU |
Gross weight |
597 g |
General data - Features
Integral system diagnostics, general |
Oui |
Safety classification |
Standards |
EN ISO 13849-1 EN IEC 61508 |
Safety classification - Safety inputs 2-channels |
Performance Level, up to |
e |
Category |
4 |
Diagnostic Coverage (DC) Level |
99 % |
PFH value |
1,10 x 10⁻⁹ /h |
PFDavg |
9,60 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Response time of local safety input ⇒ Fieldbus, maximum |
30 ms |
Notice |
Le SFB répond aux exigences comme PDDB (détecteur de proximité avec comportement défini en cas de défauts) selon EN 60947-5-3 en liaison avec des capteurs magnétiques (2 contacts NF) jusqu'à PL e / SIL 3. |
Safety classification - Safety inputs 1-channel |
Performance Level, up to |
d |
Category |
2 |
Diagnostic Coverage (DC) Level |
90 % |
PFH value |
2,30 x 10⁻⁷ /h |
PFDavg |
2,00 x 10⁻² |
Safety Integrity Level (SIL), suitable for applications in |
1 |
Mission time |
20 Year(s) |
Response time of local safety input > Fieldbus, maximum |
30 ms |
Test interval for error detection |
10 s |
Safety classification - Safety outputs 1-channel |
Performance Level, up to |
d |
Category |
3 |
Diagnostic Coverage (DC) Level |
90 % |
PFH value |
1,00 x 10⁻⁷ /h |
PFDavg |
8,80 x 10⁻³ |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Mission time |
20 Year(s) |
Reaction time Fieldbus > local safety output |
50 ms |
Safety classification - Safety outputs 2-channels |
Performance Level, up to |
e |
Category |
4 |
Diagnostic Coverage (DC) Level |
99 % |
PFH value |
1,20 x 10⁻⁹ /h |
PFDavg |
1,10 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Reaction time Fieldbus > local safety output |
50 ms |
Mechanical data
Mounting |
Vis |
Type of the fixing screws |
2x M6 |
Tightening torque of the fixing screws, maximum |
3 Nm |
Type of the fixing screws, viewing window |
2x TX10 (Torx) |
Tightening torque of the fastening screws for the viewing window, maximum |
0,6 Nm |
Mechanical data - Connection technique
Termination |
Connecteur femelle/mâle M12 |
Terminal connector, Input/Output |
X0 - X7: M12, 8-pôles, codage A |
Terminal Connector, Power I/O |
M12-POWER, 4 pôles, codage T |
Terminal Connector, Field bus |
M12, 4 pôles, codage D |
Tightening torque of electrical connection, minimum |
0,8 Nm |
Tightening torque of electrical connection, maximum |
1,5 Nm |
Mechanical data - Dimensions
Length |
222,8 mm |
Width |
63 mm |
Height |
36,1 mm |
Ambient conditions
Degree of protection |
IP66 IP67 |
Ambient temperature |
-25 ... +55 °C |
Storage and transport temperature |
-25 ... +70 °C |
Relative humidity, minimum |
10 % |
Relative humidity, maximum |
95 % |
Note (Relative humidity) |
sans condensation |
Resistance to vibrations |
10 … 150 Hz, amplitude 0,35 mm / 5 g |
Restistance to shock |
30 g / 11 ms |
Protection class |
III |
Permissible installation altitude above sea level, maximum |
2.000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0,8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC -15 % / +10 % |
Current consumption |
200 mA |
Rated operating voltage |
24 VDC |
Operating current |
10.000 mA |
Note (Electrical data, Fuse rating) |
External fuse protection required ≤ 10A slow blow when used to UL 61010. |
Time to readiness, maximum |
12.000 ms |
Device Watchdog Time |
12 ms |
Device Acknowledgement Time, maximum |
25 ms |
Reaction Time Safety Input, maximum |
30 ms |
Reaction Time Safety Output, maximum |
50 ms |
Electrical data - Communication protocols
Feldbus Protokoll |
EtherCAT / FSoE |
Fieldbus specification |
V1.0.10 |
Specification safety fieldbus |
V1.2.0 |
Transfer rate |
100 Mbit/s Full Duplex |
Adressing |
Topology dependent |
Integrated switch |
Dual Port, 100 Mbit/s |
Service interface |
WEB-Interface HTTP |
Electrical data - Device Ports
Bezeichnung, Geräteanschlüsse |
X0 ... X7 |
Cable length, device port |
30 m |
Electrical data - Power supply external devices
Designation, Power supply |
A1 and A2 |
Rated operating voltage |
24 VDC |
Rated operating current |
800 mA |
Internal electrical fuse |
1.5 A (Integrated automatic resettable fuse) |
Electrical data - Safety digital inputs
Designation, Safety inputs |
X1 and X2 |
Switching thresholds |
−3 V … 5 V (Low) 13 V ... 30 V (High) |
Current consumption at 24 V |
6 mA |
Permissible residual drive current |
1 mA |
Test pulse duration, minimum |
0,01 ms |
Test pulse duration, maximum |
1 ms |
Test pulse interval, minimum |
20 ms |
Test pulse interval, maximum |
120.000 ms |
Classification ZVEI CB24I, Sink |
C1 |
Classification ZVEI CB24I, Source |
C1 C2 C3 |
Electrical data - Safety digital outputs
Designation, Safety outputs |
DO |
Design of control elements |
protégé contre les courts-circuits, commutation P |
Voltage drop Ud, maximum |
2 V |
Leakage current Ir, maximum |
0,5 mA |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,8 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,8 A |
Note, Utilisation category DC-13 |
Inductive load, maximum 400 mH |
Switching frequency, maximum |
1 Hz |
Test pulse duration, maximum |
1 ms |
Test pulse interval, minimum |
15 ms |
Test pulse interval, maximum |
500 ms |
Classification ZVEI CB24I, Source |
C1 |
Classification ZVEI CB24I, Sink |
C1 |
Electrical data - Diagnostic inputs / FB-Interface
Designation, Diagnostic inputs / FB-Interface |
DI |
Switching thresholds |
−3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24V |
12 mA |
Input debounce filter |
10 ms |
Data transfer rate FB-Interface |
19,2 kBaud |
Electrical data - Test pulse output
Designation, Test pulse outputs |
Y1 and Y2 |
Design of control elements |
protégé contre les courts-circuits, commutation P |
Voltage drop Ud, maximum |
1 V |
Current leakage Ir, maximum |
0,5 mA |
Voltage, Utilisation category DC-12 |
24 VDC |
Y1 rated current at 24 V |
15 mA |
Y2 rated current at 24 V |
10 mA |
Y2 rated current at 0 V |
30 mA |
Test pulse interval, typical |
500 ms |
Test pulse duration, maximum |
1 ms |
Classification ZVEI CB24I, Sink |
C1 |
Classification ZVEI CB24I, Source |
C1 |
LED status display - LED 01
LED status |
LED d'erreur raccordement pour appareil |
LED position |
E: 0 ... 7 |
LED colour |
verte / rouge |
LED status display - LED 02
LED status |
LED d'entrée raccordement pour appareil |
LED position |
I: 0 ... 7 |
LED colour |
jaune |
LED status display - LED 03
LED status |
Link / Activity-LED Ethernet Port |
LED position |
L / A: IN + OUT |
LED colour |
verte |
LED status display - LED 05
LED status |
EtherCAT RUN LED |
LED position |
"RUN": Module |
LED colour |
verte |
LED status display - LED 06
LED status |
EtherCAT error LED |
LED position |
"ERR": module |
LED colour |
rouge |
LED status display - LED 07
LED status |
Fieldbox Diag-LED |
LED position |
"Diag": module |
LED colour |
verte / rouge |
LED status display - LED 08
LED status |
Power-LED boitier de distribution |
LED position |
"Pwr": module |
LED colour |
verte |
Other data
Note (applications) |
Boîtier de distribution de sécurité avec E/S décentralisées |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Manuel de référence
Certificat CE avec examen de type
Certificat UL
Certificat UKCA
Fiches descriptives des appareils
Information client
Brochure
Bibliothèque/Library SISTEMA-VDMA
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 09/09/2025 02:27