schmersal_s_icon.png

SFB-EC-8M12-IOP

Varenummer: 103047531

  • For tilkobling av opptil 8 sikkerhetskoblingsanlegg
  • Integrert dual-port bryter
  • Tetthetsgrad IP66, IP67

Bestillingsinformasjon

Produkt-typebetegnelse

SFB-EC-8M12-IOP

Artikkelnummer (bestillingsnummer)

103047531

EAN (European Article Number)

4030661628707

eCl@ss number, version 12.0

27-24-26-04

eCl@ss number, version 11.0

27-24-26-04

eCl@ss-nummer, versjon 9.0

27-24-26-04

ETIM number, version 7.0

EC001599

ETIM number, version 6.0

EC001599

Tillatelser - Standard

Data

TÜV

cULus

UKCA

Gobale egenskaper

Standard

EN IEC 61131-1

EN IEC 61131-2

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Kapslingsmateriale

Plast, polyamid PA 6 GF

Materialet i identifikasjonsplate

Plast, polyamid PA

Material of viewing window

Polyamide PACM 12

Material of electronic encapsulation

Polyurethane 2K PU

Bruttovekt

597 g

Gobale egenskaper - Karakteristikker

Integrert indikator, generelt

Ja

Klassifisering

Standarder, forskrifter

EN ISO 13849-1

EN IEC 61508

Klassifisering - sikkerhetsinngang 2-kanal

Performance Level, up to

e

Kontrollkategori

4

Diagnostic Coverage (DC) Level

99 %

PFH-verdi

1,10 x 10⁻⁹ /h

PFDavg

9,60 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Oppgavetid

20 år

Response time of local safety input ⇒ Fieldbus, maximum

30 ms

Notice

The SFB fulfils the requirements as PDDB (proximity switch with defined behaviour under fault conditions) according to EN 60947-5-3 in combination with magnetic sensors (2 NC contacts) up to PL e / SIL 3.

Klassifisering - sikkerhetsinnganger 1-kanal

Performance Level, up to

d

Kontrollkategori

2

Diagnostic Coverage (DC) Level

90 %

PFH-verdi

2,30 x 10⁻⁷ /h

PFDavg

2,00 x 10⁻²

Safety Integrity Level (SIL), suitable for applications in

1

Oppgavetid

20 år

Response time of local safety input > Fieldbus, maximum

30 ms

Test interval for error detection

10 s

Klassifisering - sikkerhetsutgang 1-kanal

Performance Level, up to

d

Kontrollkategori

3

Diagnostic Coverage (DC) Level

90 %

PFH-verdi

1,00 x 10⁻⁷ /h

PFDavg

8,80 x 10⁻³

Safety Integrity Level (SIL), suitable for applications in

2

Oppgavetid

20 år

Reaction time Fieldbus > local safety output

50 ms

Klassifisering - sikkerhetsutgang 2-kanal

Performance Level, up to

e

Kontrollkategori

4

Diagnostic Coverage (DC) Level

99 %

PFH-verdi

1,20 x 10⁻⁹ /h

PFDavg

1,10 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Oppgavetid

20 år

Reaction time Fieldbus > local safety output

50 ms

Mekaniske data

Montering

Skruer

Type of the fixing screws

2x M6

Tightening torque of the fixing screws, maximum

3 Nm

Type of the fixing screws, viewing window

2x TX10 (Torx)

Tightening torque of the fastening screws for the viewing window, maximum

0,6 Nm

Mechanical data - Connection technique

Konnektor stikk

M12 konnektorsokkel / -stik

Konnektor stikk, inngang/utgang

X0 - X7: M12, 8-polet, A-kodet

Terminal Connector, Power I/O

M12 POWER, 4-pole, T-coded

Terminal Connector, Field bus

M12, 4-pole, D-coded

Tightening torque of electrical connection, minimum

0,8 Nm

Tightening torque of electrical connection, maximum

1,5 Nm

Mekaniske data - mål

Lengde

222,8 mm

Bredde

63 mm

Høyde

36,1 mm

Omgivelsesbetingelser

Tetthetsgrad

IP66

IP67

Ambient temperature

-25 ... +55 °C

Storage and transport temperature

-25 ... +70 °C

Relativ fuktighet, minimum

10 %

Relativ fuktighet, maksimum

95 %

Note (Relative humidity)

ikke kondenserende

Resistent mot vibrasjoner iht. EN 60068-2-6

10 … 150 Hz, Amplitude 0,35 mm / 5 g

sjokkresitanse

30 g / 11 ms

Protection class

III

Permissible installation altitude above sea level, maximum

2 000 m

Ambient conditions - Insulation values

Isolasjonsspenning

32 VDC

Nominell impulsmotstandsspenning

0,8 kV

Overvoltage category

III

Forurensningsgrad iht. IEC/EN 60664-1

3

Elektriske data

Operating voltage

24 VDC -15 % / +10 %

Driftsstrøm

200 mA

Rated operating voltage

24 VDC

driftssstrøm

10 000 mA

Merknad (elektriske data, sikring)

External fuse protection required ≤ 10A slow blow when used to UL 61010.

Tid til beredskap, maksimum

12 000 ms

Device Watchdog Time

12 ms

Device Acknowledgement Time, maximum

25 ms

Reaction Time Safety Input, maximum

30 ms

Reaction Time Safety Output, maximum

50 ms

Elektriske data – kommunikasjonsprotokoller

Feldbus Protokoll

EtherCAT / FSoE

Fieldbus specification

V1.0.10

Specification safety fieldbus

V1.2.0

Transfer rate

100 Mbit/s Full Duplex

Adressing

Topology dependent

Integrated switch

Dual Port, 100 Mbit/s

Service interface

WEB-Interface HTTP

Electrical data - Device Ports

Bezeichnung, Geräteanschlüsse

X0 ... X7

Cable length, device port

30 m

Electrical data - Power supply external devices

Designation, Power supply

A1 and A2

Rated operating voltage

24 VDC

Rated operating current

800 mA

Internal electrical fuse

1.5 A (Integrated automatic resettable fuse)

Electrical data - Safety digital inputs

Designation, Safety inputs

X1 and X2

Koplingsterskler på sikkerhetsinnganger

−3 V … 5 V (Low)

13 V ... 30 V (High)

Driftsstrøm for sikkerhetsinngangene ved 24 V

6 mA

Permissible residual drive current

1 mA

Test pulse duration, minimum

0,01 ms

Test pulse duration, maximum

1 ms

Test pulse interval, minimum

20 ms

Test pulse interval, maximum

120 000 ms

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital outputs

Designation, Safety outputs

DO

Sikkerhetsutgang

short-circuit proof, p-type

Voltage drop Ud, maximum

2 V

Leakage current Ir, maximum

0,5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,8 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,8 A

Note, Utilisation category DC-13

Inductive load, maximum 400 mH

Switching frequency, maximum

1 Hz

Test pulse duration, maximum

1 ms

Test pulse interval, minimum

15 ms

Test pulse interval, maximum

500 ms

Classification ZVEI CB24I, Source

C1

Classification ZVEI CB24I, Sink

C1

Electrical data - Diagnostic inputs / FB-Interface

Designation, Diagnostic inputs / FB-Interface

DI

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24V

12 mA

Input debounce filter

10 ms

Data transfer rate FB-Interface

19,2 kBaud

Elektriske data - Taktutgang

Designation, Test pulse outputs

Y1 and Y2

Design of control elements

short-circuit proof, p-type

Voltage drop Ud, maximum

1 V

Current leakage Ir, maximum

0,5 mA

Voltage, Utilisation category DC-12

24 VDC

Y1 rated current at 24 V

15 mA

Y2 rated current at 24 V

10 mA

Y2 rated current at 0 V

30 mA

Test pulse interval, typical

500 ms

Test pulse duration, maximum

1 ms

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

Statusvisning - LED 01

LED status

Error LED device port

LED position

E: 0 ... 7

LED-farge

grønn/rød

Statusvisning - LED 02

LED status

Input LED device port

LED position

I: 0 ... 7

LED-farge

Gul

Statusvisning - LED 03

LED status

Link / Activity-LED Ethernet Port

LED position

L / A: IN + OUT

LED-farge

grønn

Statusvisning - LED 05

LED status

EtherCAT RUN LED

LED position

"RUN": Module

LED-farge

grønn

Statusvisning - LED 06

LED status

EtherCAT error LED

LED position

"ERR": Module

LED-farge

rød

Statusvisning - LED 07

LED status

Fieldbox Diag-LED

LED position

"Diag": Module

LED-farge

grønn/rød

Statusvisning - LED 08

LED status

Power-LED fieldbox

LED position

"Pwr": Module

LED-farge

grønn

Diverse data

Merknad (app-applikasjoner)

Sikker feltboks med desentralisert I/Os

Språk filter

Enhetsbeskrivelsesfiler

Last ned den nyeste versjonen av Adobe Reader


Schmersal Nordiska AB, F O Petersons gata 28, S-421 31 Västra Frölunda

Data og verdier er kontrollert omhyggelig. Bilder kan avvike fra originalen. Ytterligere tekniske data finner du i manualen. Tekniske modifiseringer og feil kan forkomme.

Generert til 30.11.2024, 17:16