BDF200-FB-B-B-LT-LT-2875
- integrated FB interface for connection to the Safety-Field-Box SFB
- Pos 1: Blanking plug
- Pos 2: Blanking plug
- Pos 3: illuminated pushbutton 2875 with changeable colors
- Pos 4: illuminated pushbutton 2875 with changeable colors
- slender shock-proof thermoplastic enclosure
- 安装在一个符合人体工程学的有利位置
- 安装在标准铝材上
- 带电子OSSD的紧急停机
订货数据
型号 |
BDF200-FB-B-B-LT-LT-2875 |
商品编号(订购编号) |
103040686 |
EAN(欧洲商品编号) |
4030661555249 |
eCl@aa number,版本:12.0 |
27-37-12-16 |
eCl@aa number,版本:11.0 |
27-37-12-16 |
eCl@aa number,版本:9.0 |
27-37-12-16 |
ETIM 编号,7.0 版 |
EC000225 |
ETIM 编号,6.0 版 |
EC000225 |
注释 (订货数据) |
备注:参见订购代码 |
许可 - 标准
证书 |
cULus |
总体数据
标准型 |
EN ISO 13849-1 EN ISO 13850 EN IEC 60947-5-1 EN IEC 60947-5-5 EN IEC 61508 |
|
气压 |
DIN EN 60068 |
|
外壳材料 |
塑料,玻璃纤维加固热塑塑料,自熄灭 |
|
响应时间,最大 |
50 ms |
|
风险持续期,最大 |
100 ms |
|
使用位置,位置 1 |
插头 |
|
使用位置,位置 2 |
|
|
使用位置,位置 3 |
带灯按钮,颜色可更换 |
|
使用位置,位置 4 |
带灯按钮,颜色可更换 |
|
毛重 |
280 g |
总体数据 - 产品特性
串联诊断 |
否 |
外勤箱接口 |
1 |
指示灯 |
否 |
安全功能 |
是 |
故障安全数字输出数量 |
2 |
安全评估
标准型 |
EN ISO 13849-1 EN IEC 61508 |
性能水平,最高 |
e |
类别 |
4 |
PFH值 |
2.89 x 10⁻¹⁰ /h |
注(PFH值) |
高达最多5,000次开关循环/年 |
安全完整性等级 (SIL),停止 0,适用于以下应用 |
3 |
任务时间 |
20 年 |
机械参数
机械寿命,紧急停止按钮 {操作次数} |
100,000 操作 |
机械寿命,指令装置 |
1,000,000 操作 |
安装 |
内部安装孔 |
固定螺丝类型 |
2x M5 |
机械参数 - 连接技术
端子(机械) |
联接插头:M12,8芯,A编码 |
机械参数 - 尺寸
宽度 |
40 mm |
高度 |
69 mm |
深度 |
233.5 mm |
环境条件
防护等级 |
IP65 |
工作环境温度 |
-25 ... +65 °C |
储存和运输温度 |
-25 ... +85 °C |
抗振动 |
10 ... 150 Hz, 振幅 .35 mm / 5 g |
耐冲击 |
30 g / 11 ms |
防护等级 |
III |
最大允许安装海拔高度 |
2,000 m |
环境条件 - 绝缘值
额定绝缘电压 Ui |
32 VDC |
额定冲击耐受电压 Uimp |
0.8 kV |
过电压级别 |
III |
污染等级 |
3 |
电气参数
工作电压 |
24 VDC -15 % / +10 % |
空载电源电流 I0, 典型 |
35 mA |
额定工作电压 |
24 VDC |
工作电流 |
600 mA |
要求额定短路电流 |
100 A |
准备就绪时间,最大 |
2,000 ms |
转换频率,最大 |
1 Hz |
电子参数 - 安全数字输入
指定,安全输入 |
X1 和 X2 |
开关阈值 |
−3 V … 5 V (Low) 15 V … 30 V (High) |
24V时,电流消耗 |
5 mA |
测试脉冲持续时间, 最大 |
1 ms |
测试脉冲间隔, 最低限度 |
100 ms |
分类 ZVEI CB24I,接收器 |
C1 |
分类 ZVEI CB24I,信号源 |
C1 C2 C3 |
电气参数 - 安全数字输出
指定,安全输出 |
Y1和Y2 |
控制元件的设计 |
短路保护,P型 |
电压降 Ud, 最大电压降 Ud, 最大 |
1 V |
泄漏电流 Ir, 最大植 |
0.5 mA |
电压,应用类别 DC-12 |
24 VDC |
电流,应用类别 DC-12 |
0.25 A |
电压,应用类别 DC-13 |
24 VDC |
电流,应用类别 DC-13 |
0.25 A |
测试脉冲间隔,典型 |
1000 ms |
测试脉冲持续时间, 最大 |
1 ms |
分类 ZVEI CB24I,信号源 |
C1 |
分类 ZVEI CB24I,接收器 |
C1 |
电子参数 - 串行诊断SD
指定,串联诊断SD |
OUT |
工作电流 |
10 mA |
控制元件的设计 |
短路保护,P型 |
布线电容 |
50 nF |
引脚分配
PIN 1 |
A1 电源电压 UB |
PIN 2 |
X1 安全输入 1 |
PIN 3 |
A2 GND |
PIN 4 |
Y1 安全输出 1 |
PIN 5 |
OUT 串行诊断输出 |
PIN 6 |
X2 安全输入 2 |
PIN 7 |
Y2 安全输出 2 |
PIN 8 |
n.c. |
语言条件
数据表
操作指南及符合性声明
SISTEMA-VDMA 数据库
下载最新版本的Adobe Reader
产品图片(单独目录照片)
尺寸图 基本组件
工作原理
EU Declaration of Conformity |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | BDF200-SD BDF200-FB |
Type: | See ordering code |
Description of the component: | Control panel with or without safety function and integrated SD interface or FB interface |
Relevant Directives: | Machinery Directive 1) | 2006/42/EC |
Low Voltage Directive | 2014/35/EU | |
EMC-Directive | 2014/30/EU | |
RoHS-Directive | 2011/65/EU | |
1) for device versions with safety function (emergency stop) |
Applied standards: | EN 60947-5-1:2017 + AC:2020 1) EN 60947-5-5:1997 + A1:2005 + A11:2013 + A2:2017 1) EN ISO 13849-1:2023 1) EN 61508-1:2010 |
1) Notified body for Type Examination: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
1) EC-Type Examination Certificate: | 01/205/5613.01/24 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, May 23, 2024 |
Authorised signature Philip Schmersal Managing Director |
UK Declaration of Conformity |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | BDF200-SD BDF200-FB |
Type: | See ordering code |
Description of the component: | Control panel with or without safety function and integrated SD interface or FB interface |
Relevant legislation: | Supply of Machinery (Safety) Regulations 1) | 2008 |
Electrical Equipment (Safety) Regulations | 2016 | |
Electromagnetic Compatibility Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 | |
1) for device versions with safety function (emergency stop) |
Designated standards: | EN 60947-5-1:2017 + AC:2020 1) EN 60947-5-5:1997 + A1:2005 + A11:2013 + A2:2017 1) EN ISO 13849-1:2023 1) EN 61508-1:2010 |
1) Approved body for Type Examination: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
1) Type examination certificate: | 01/205/5613.01/24 |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, May 23, 2024 |
Authorised signature Philip Schmersal Managing Director |
施迈赛工业开关制造(上海)有限公司, 上海市青浦区漕盈路3336号,
所涉及的详细信息和数据已经过仔细检查。 图像可能与原始图像有所不同。 您可在说明书中进一步获得技术数据。 可能会有技术修改和错误。
生成日期 2024/12/26 上午6:03