RSS260-SD-ST
RSS260-SD-ST
Product type description: RSS260-(1)-(2)-(3)-(4)-(5) |
(1) | |
without | Standard coding |
I1 | Individual coding |
I2 | Individual coding, multiple teaching |
(2) | |
D | With diagnostic output |
SD | With serial diagnostic function 1) |
(3) | |
without | Standard version without feedback circuit monitoring EDM (External Device Monitoring) |
F0 | EDM with automatic reset 1) |
F1 | EDM with manual reset 1) |
(4) | |
without | Without EMERGENCY STOP |
Q | Acknowledge input error with EMERGENCY STOP 1) |
(5) | |
without | Connecting cable (lenght in m) |
ST | Connector plug M8, 8-pole |
LSTM12-8-0,25M | Cable 0.25 m long with connector M12, 8-pole |
LSTM8-8-0,1M | Cable 0.1 m long with connector M8, 8-pole |
LSTM12-5-0.25M | Cable 0.25 m long with connector M12, 5-pole |
(*) | |
1) | only for versions -ST, -LSTM12-8-0.25M and -LSTM8-8-0.1M |
- Universal coding with RFID technology
- 1 x connector plug M8
- Frontal and lateral actuation enabled
- Max. 31 sensors can be wired in series.
- Thermoplastic enclosure
- Simple mounting without additional angle
- RFID-technology for needs-based protection against tampering
Ordering data
PM_TYPE_NAME |
RSS260-SD-ST |
PM_ORDER_NUMBER |
103003605 |
SAP_EAN |
4030661436449 |
CODE_ECLASS_V12P0 |
27-27-46-01 |
CODE_ECLASS_V11P0 |
27-27-24-03 |
CODE_ECLASS_V09P0 |
27-27-24-03 |
CODE_ETIM_V07P0 |
EC001829 |
CODE_ETIM_V06P0 |
EC001829 |
Approvals - Standards
PNV_NORM_CERTIFICATION |
TÜV cULus FCC IC ANATEL |
General data
NORM_STANDARD |
EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
CODE_GENERAL_INFO |
Universelle Codierung |
CODE_CODING_LEVEL_ISO14119 |
gering |
DESIGN_ACTIVE_PRINCIPLE |
RFID |
TIME_FREQ_BAND_RFID |
125 |
PWR_TRANSMIT_RFID_MAX |
-6 |
DESIGN_HOUSING |
Quader |
DESIGN_INST_CONDIT |
nicht bündig |
DESIGN_SENSOR_TOPOLOGY |
Reihenschaltungsgerät |
MAT_HOUSING |
Kunststoff, Thermoplast, selbstverlöschend |
MAT_ACTIVE_SURFACE |
Kunststoff, Thermoplast |
TIME_RESPONSE_MAX |
100 |
TIME_DURAT_OF_RISK_MAX |
200 |
TIME_RESPONSE_ACT_MAX |
100 |
SAP_WEIGHT_GROSS |
61 |
General data - Features
YN_SERIAL_DIAGN |
Ja |
YN_SHORT_CIRCUIT_DETECT |
Ja |
YN_CROSS_SHORT_DETECT |
Ja |
YN_SERIE_WIRING |
Ja |
YN_FIT_FOR_SAFE_FUNC |
Ja |
YN_CASCADABLE |
Ja |
YN_INTEGR_DISPLAY_STATUS |
Ja |
NUM_OF_LED |
3 |
NUM_OF_POL |
8 |
NUM_OF_SDOUT |
2 |
NUM_OF_SERIE_WIRING_SENSOR |
31 |
Safety classification |
SAFE_NORM_STANDARD |
EN ISO 13849-1 EN IEC 61508 |
SAFE_PERFORM_LEVEL |
e |
SAFE_CAT |
4 |
SAFE_PFH_VALUE |
6,80 x 10⁻¹⁰ |
SAFE_PFD_VALUE |
1,20 x 10⁻⁴ |
SAFE_SIL |
3 |
SAFE_MISSION_TIME |
20 |
Mechanical data
APP_ACT_PLANE |
seitlich vorderseitig |
DESIGN_ACTIVE_AREA |
seitlich vorne |
DESIGN_MOUNTING |
Zur Montage der Sensoren reichen üblicherweise 20 mm Schraubenlänge. Bei Verwendung der Montageplatten werden 25 mm lange Schrauben empfohlen. |
DESIGN_MOUNTING_SCREW |
2x M4 |
TRQ_TIGHTEN_SCREW_MOUNTING_MAX |
0,8 |
Mechanical data - Switching distances
DIM_RANGE_SWITCH_DIST_TYP_FRONT |
12 |
DIM_RANGE_SWITCH_DIST_TYP_SIDE |
9 |
DIM_RANGE_SWITCH_DIST_ON_FRONT |
10 |
DIM_RANGE_SWITCH_DIST_OFF_FRONT |
18 |
DIM_RANGE_SWITCH_DIST_ON_SIDE |
6 |
DIM_RANGE_SWITCH_DIST_OFF_SIDE |
15 |
NOTE_RANGE_SWITCH_DIST_ON |
Die Angaben des gesicherten Schaltabstands Sao beziehen sich auf einen Temperaturbereich −10 °C … +60 °C. Bei einem Temperaturbereich von −28 °C … +65 °C reduziert sich Sao um 2 mm. |
NOTE_DIM_RANGE_SWITCH_DIST_GENERAL |
Alle Angaben der Schaltabstände gemäß EN IEC 60947-5-3 Axialer Versatz Sicherheits-Sensor und Betätiger tolerieren einen horizontalen und vertikalen Versatz zueinander. Der mögliche Versatz ist abhängig vom Abstand der aktiven Flächen von Sensor und Betätiger. Innerhalb des Toleranzbereiches ist der Sensor aktiv geschaltet. |
DIM_DIST_HYSTERESIS_MECH_MAX |
2 |
DIM_DIST_REPEAT_ACCURACY |
0,5 |
NOTE_DIM_DIST_REPEAT_ACCURACY |
Seitlicher Versatz: Die lange Seitenfläche erlaubt einen max. Höhenversatz (x) von Sensor und Betätiger um 8 mm (z.B. Montagetoleranz oder durch Absacken der Schutztür). Der Querversatz (y) beträgt max. ± 18 mm (siehe Abbildung: Funktionsweise).Mindestabstand von zwei Sensorsystemen 100 mm |
Mechanical data - Connection technique
NOTE_LENGTH_SENSOR_CHAIN_MAX |
Leitungslänge und Leitungsquerschnitt verändern den Spannungsfall in Abhängigkeit vom Ausgangsstrom |
NOTE_SERIE_WIRING_SENSOR |
Anzahl der Geräte unbegrenzt, externen Leitungsschutz beachten, max. 31 Geräte bei serieller Diagnose SD |
REVIEW_ELEC_WIRING_GENERAL |
Steckverbinder M8, 8-polig |
Mechanical data - Dimensions
DIM_LENGTH_SENSOR |
29,5 |
DIM_WIDTH_SENSOR |
39,2 |
DIM_HEIGHT_SENSOR |
18 |
Ambient conditions
DESIGN_IP_CLASS_GENERAL |
IP65 IP67 |
TEMP_AMB_GPV |
-28 ... +65 °C |
TEMP_STORAGE_AND_TRANSPORT_GPV |
-28 ... +85 °C |
APP_REL_HUMIDITY_MAX |
93 |
NOTE_REL_HUMIDITY |
nicht kondensierend nicht vereisend |
REVIEW_RESIST_VIBRAT_EN60068_2_6 |
10 … 55 Hz, Amplitude 1 mm |
REVIEW_RESTIST_TO_SHOCK |
30 g / 11 ms |
DIM_HEIGHT_OPERAT_ALTITUDE_MAX |
2.000 |
Ambient conditions - Insulation values
VOLT_RATED_INSULAT |
32 VDC |
VOLT_RATED_IMPULSE_WITHSTAND |
0,8 |
DESIGN_OVERVOLT_CAT_VDE100_ROMAN |
III |
DESIGN_DEG_OF_POLLUT_VDE100 |
3 |
Electrical data
VOLT_OPERAT_GPV |
24 VDC -15 % / +10 % (stabilisiertes PELV-Netzteil) |
CURR_OPERAT_MIN |
0,5 |
CURR_NO_LOAD_CURR |
35 |
VOLT_RATED_OPERAT_DC |
24 |
CURR_RATED_OPERAT |
600 |
CURR_REQUIRED_RATED_SHORT_CIRCUIT |
100 |
TIME_TO_READINESS_MAX |
2.000 |
TIME_SWITCH_FREQ_MAX |
1 |
ELEC_FUSE_OPERAT_CURR_MAX |
2 |
Electrical data - Safety digital inputs
ELEC_DEV_PORT_SDIN |
X1 und X2 |
CURR_CONSUMPT_SDIN |
5 |
TIME_TEST_PULSE_DURAT_SDIN_MAX |
1 |
TIME_TEST_PULSE_INTERVAL_SDIN_MIN |
100 |
ELEC_CLASS_CB24I_SINK_SDIN |
C1 |
ELEC_CLASS_CB24I_SOURCE_SDIN |
C1 C2 C3 |
Electrical data - Safety digital outputs
ELEC_DEV_PORT_SOUT |
Y1 und Y2 |
CURR_RATED_OPERAT_SDOUT |
250 |
CURR_SOUT_MAX |
0,25 |
DESIGN_SWITCH_OUT_SAFE |
kurzschlussfest, p-schaltend |
VOLT_DROP_SDOUT_MAX |
1 |
CURR_LEAKAGE_SDOUT_MAX |
0,5 |
VOLT_UTILISAT_CAT_DC12_SDOUT |
24 |
CURR_UTILISAT_CAT_DC12_SDOUT |
0,25 |
VOLT_UTILISAT_CAT_DC13_SDOUT |
24 |
CURR_UTILISAT_CAT_DC13_SDOUT |
0,25 |
TIME_TEST_PULSE_INTERVAL_SDOUT_TYP |
1000 |
TIME_TEST_PULSE_DURAT_SDOUT_MAX |
1 |
ELEC_CLASS_CB24I_SOURCE_SDOUT |
C2 |
ELEC_CLASS_CB24I_SINK_SDOUT |
C1 C2 |
Electrical data - Serial diagnostic SD
ELEC_DEV_PORT_INTERFACE_SD |
OUT |
CURR_OPERAT_SD |
150 |
DESIGN_SWITCH_SD |
kurschlussfest |
ELEC_WIRING_CPTY_SD_MAX |
50 |
Electrical data - Electromagnetic compatibility (EMC)
NORM_EMC_INTERFERING_RADIAT |
IEC 61000-6-4 |
Status indication
NOTE_LED_STATUS_INDICAT |
gelbe LED: Betriebszustand grüne LED: Versorgungsspannung rote LED: Fehler |
Pin assignment
ELEC_CON_1_PIN_ASSIGN_1 |
A1 Ue: weiß |
ELEC_CON_1_PIN_ASSIGN_2 |
X1 Sicherheitseingang 1: braun |
ELEC_CON_1_PIN_ASSIGN_3 |
A2 GND: grün |
ELEC_CON_1_PIN_ASSIGN_4 |
Y1 Sicherheitsausgang 1: gelb |
ELEC_CON_1_PIN_ASSIGN_5 |
OUT serieller Diagnoseausgang: grau |
ELEC_CON_1_PIN_ASSIGN_6 |
X2 Sicherheitseingang 2: rosa |
ELEC_CON_1_PIN_ASSIGN_7 |
Y2 Sicherheitsausgang 2: blau |
ELEC_CON_1_PIN_ASSIGN_8 |
IN serieller Diagnoseeingang: rosa |
Scope of delivery
SCOPE_OF_DELIV_GENERAL |
Der Betätiger ist nicht im Lieferumfang enthalten. |
Accessory
RECOMM_ACT |
RST16-1 RST-U-2 RST260-1 |
RECOMM_SAFE_SWITCH_DEV |
PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
Note
NOTE_GENERAL |
Anforderungen an die Auswertung: Zweikanaliger Sicherheitseingang, geeignet für p-schaltende Sensoren mit Schließerfunktion. Die Funktionstests der Sensoren mit zyklischem Abschalten der Sensorausgänge für max. 1 ms müssen von der Auswertung toleriert werden. Eine Querschlusserkennung in der Auswertung ist nicht notwendig. |
Sprachfilter
Datenblatt
Betriebsanleitung und Konformitätserklärung
UL-Zertifikat
FCC-Zertifikat
IC-Zertifikat
ANATEL-Zertifikat
Broschüre
SISTEMA-VDMA Bibliothek/Library
Download der aktuellen Version von Adobe Reader
Produktbild (Katalogeinzelphoto )
Maßzeichnung Grundgerät
Video ID: SD-Interface-Mr-Safety
EU-Konformitätserklärung | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Erklärung: | Hiermit erklären wir, dass die nachfolgend aufgeführten Bauteile aufgrund der Konzipierung und Bauart den Anforderungen der unten angeführten Europäischen Richtlinien entsprechen. |
Bezeichnung des Bauteils: | RSS260 |
Typ: | siehe Typenschlüssel |
Beschreibung des Bauteils: | Berührungslos wirkender Sicherheits-Sensor |
Einschlägige Richtlinien: | Maschinenrichtlinie | 2006/42/EG |
RED-Richtlinie | 2014/53/EU | |
RoHS-Richtlinie | 2011/65/EU |
Angewandte Normen: | EN 60947-5-3:2013 EN 300 330 V2.1.1:2017 EN ISO 14119:2013 EN ISO 13849-1:2023 EN 61508 Teile 1-7:2010 |
Benannte Stelle der Baumusterprüfung: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln Kenn-Nr.: 0035 |
EG-Baumusterprüfbescheinigung: | 01/205/5348.04/25 |
Bevollmächtigter für die Zusammenstellung der technischen Unterlagen: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Ort und Datum der Ausstellung: | Wuppertal, 9. Januar 2025 |
![]() |
Rechtsverbindliche Unterschrift Philip Schmersal Geschäftsführer |
UK Declaration of Conformity | ![]() |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | RSS260 |
Type: | See ordering code |
Description of the component: | Non-contact safety sensor |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Radio Equipment Regulations | 2017 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN 60947-5-3:2013 EN 300 330 V2.1.1:2017 EN ISO 14119:2013 EN ISO 13849-1:2015 IEC 61508 parts 1-7:2010 |
Approved body for Type Examination: | TÜV Rheinland UK Ltd. 1011 Stratford Road Solihull, B90 4BN ID: 2571 |
Type examination certificate: | 01/205U/5348.00/22 |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, November 2, 2022 |
![]() |
Authorised signature Philip Schmersal Managing Director |
施迈赛工业开关制造(上海)有限公司, 上海市青浦区漕盈路3336号,
Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.
Generiert am: 22.06.2025, 14:34