schmersal_s_icon.png

SFB-EC-8M12-IOP

Artikelnummer: 103047531

  • Safety fieldbox for EtherCAT with FSoE
  • For connection of up to 8 safety switching devices
  • Integrated dual-port switch
  • Protection class IP66, IP67

Ordering data

Product type description

SFB-EC-8M12-IOP

Article number (order number)

103047531

EAN (European Article Number)

4030661628707

eCl@ss number, version 12.0

27-24-26-04

eCl@ss number, version 11.0

27-24-26-04

eCl@ss number, version 9.0

27-24-26-04

ETIM number, version 7.0

EC001599

ETIM number, version 6.0

EC001599

Approvals - Standards

Certificates

TÜV

cULus

UKCA

General data

Standards

EN IEC 61131-1

EN IEC 61131-2

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Housing material

Kunststoff, Polyamid PA 6 GF

Material of the identification label

Kunststoff, Polyamid PA

Material of viewing window

Polyamid PACM 12

Material of electronic encapsulation

Polyurethan 2K PU

Gross weight

597 g

General data - Features

Integral system diagnostics, general

Ja

Safety classification

Standards

EN ISO 13849-1

EN IEC 61508

Safety classification - Safety inputs 2-channels

Performance Level, up to

e

Category

4

Diagnostic Coverage (DC) Level

99 %

PFH value

1,10 x 10⁻⁹ /h

PFDavg

9,60 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Response time of local safety input ⇒ Fieldbus, maximum

30 ms

Notice

Die SFB erfüllt die Anforderungen als PDDB (Näherungsschalter mit definiertem Verhalten unter Fehlerbedingungen) nach EN 60947-5-3 in Verbindung mit Magnetsensoren (2 Öffner Kontakte) bis PLe / SIL 3.

Safety classification - Safety inputs 1-channel

Performance Level, up to

d

Category

2

Diagnostic Coverage (DC) Level

90 %

PFH value

2,30 x 10⁻⁷ /h

PFDavg

2,00 x 10⁻²

Safety Integrity Level (SIL), suitable for applications in

1

Mission time

20 Year(s)

Response time of local safety input > Fieldbus, maximum

30 ms

Test interval for error detection

10 s

Safety classification - Safety outputs 1-channel

Performance Level, up to

d

Category

3

Diagnostic Coverage (DC) Level

90 %

PFH value

1,00 x 10⁻⁷ /h

PFDavg

8,80 x 10⁻³

Safety Integrity Level (SIL), suitable for applications in

2

Mission time

20 Year(s)

Reaction time Fieldbus > local safety output

50 ms

Safety classification - Safety outputs 2-channels

Performance Level, up to

e

Category

4

Diagnostic Coverage (DC) Level

99 %

PFH value

1,20 x 10⁻⁹ /h

PFDavg

1,10 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Reaction time Fieldbus > local safety output

50 ms

Mechanical data

Mounting

Schrauben

Type of the fixing screws

2x M6

Tightening torque of the fixing screws, maximum

3 Nm

Type of the fixing screws, viewing window

2x TX10 (Torx)

Tightening torque of the fastening screws for the viewing window, maximum

0,6 Nm

Mechanical data - Connection technique

Termination

M12 Einbaubuchse / -Stecker

Terminal connector, Input/Output

X0 - X7: M12, 8-polig, A-codiert

Terminal Connector, Power I/O

M12 POWER, 4-polig, T-codiert

Terminal Connector, Field bus

M12, 4-polig, D-codiert

Tightening torque of electrical connection, minimum

0,8 Nm

Tightening torque of electrical connection, maximum

1,5 Nm

Mechanical data - Dimensions

Length

222,8 mm

Width

63 mm

Height

36,1 mm

Ambient conditions

Degree of protection

IP66

IP67

Ambient temperature

-25 ... +55 °C

Storage and transport temperature

-25 ... +70 °C

Relative humidity, minimum

10 %

Relative humidity, maximum

95 %

Note (Relative humidity)

nicht kondensierend

Resistance to vibrations

10 … 150 Hz, Amplitude 0,35 mm / 5 g

Restistance to shock

30 g / 11 ms

Protection class

III

Permissible installation altitude above sea level, maximum

2.000 m

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0,8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 % (stabilisiertes PELV-Netzteil)

Current consumption

200 mA

Rated operating voltage

24 VDC

Operating current

10.000 mA

Note (Electrical data, Fuse rating)

Externe Absicherung erforderlich ≤ 10A träge bei Einsatz gemäß UL 61010.

Time to readiness, maximum

12.000 ms

Device Watchdog Time

12 ms

Device Acknowledgement Time, maximum

25 ms

Reaction Time Safety Input, maximum

30 ms

Reaction Time Safety Output, maximum

50 ms

Electrical data - Communication protocols

EtherCAT / FSoE

Fieldbus specification

V1.0.10

Specification safety fieldbus

V1.2.0

Transfer rate

100 Mbit/s Full Duplex

Adressing

Topology dependent

Integrated switch

Dual Port, 100 Mbit/s

Service interface

WEB-Interface HTTP

Electrical data - Device Ports

X0 ... X7

Cable length, device port

30 m

Electrical data - Power supply external devices

Designation, Power supply

A1 und A2

Rated operating voltage

24 VDC

Rated operating current

800 mA

Internal electrical fuse

1,5 A (Intergrierte selbstrückstellende Sicherung)

Electrical data - Safety digital inputs

Designation, Safety inputs

X1 und X2

Switching thresholds

−3 V … 5 V (Low)

13 V ... 30 V (High)

Current consumption at 24 V

6 mA

Permissible residual drive current

1 mA

Test pulse duration, minimum

0,01 ms

Test pulse duration, maximum

1 ms

Test pulse interval, minimum

20 ms

Test pulse interval, maximum

120.000 ms

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital outputs

Designation, Safety outputs

DO

Design of control elements

kurzschlussfest, p-schaltend

Voltage drop Ud, maximum

2 V

Leakage current Ir, maximum

0,5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,8 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,8 A

Note, Utilisation category DC-13

Induktive Last, maximum 400 mH

Switching frequency, maximum

1 Hz

Test pulse duration, maximum

1 ms

Test pulse interval, minimum

15 ms

Test pulse interval, maximum

500 ms

Classification ZVEI CB24I, Source

C1

Classification ZVEI CB24I, Sink

C1

Electrical data - Diagnostic inputs / FB-Interface

Designation, Diagnostic inputs / FB-Interface

DI

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24V

12 mA

Input debounce filter

10 ms

Data transfer rate FB-Interface

19,2 kBaud

Electrical data - Test pulse output

Designation, Test pulse outputs

Y1 und Y2

Design of control elements

kurzschlussfest, p-schaltend

Voltage drop Ud, maximum

1 V

Current leakage Ir, maximum

0,5 mA

Voltage, Utilisation category DC-12

24 VDC

Y1 rated current at 24 V

15 mA

Y2 rated current at 24 V

10 mA

Y2 rated current at 0 V

30 mA

Test pulse interval, typical

500 ms

Test pulse duration, maximum

1 ms

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

LED status display - LED 01

LED status

Error-LED Geräteanschluss

LED position

E: 0 ... 7

LED colour

grün/rot

LED status display - LED 02

LED status

Input-LED Geräteanschluss

LED position

I: 0 ... 7

LED colour

gelb

LED status display - LED 03

LED status

Link / Activity-LED Ethernet Port

LED position

L / A: IN + OUT

LED colour

grün

LED status display - LED 05

LED status

EtherCAT RUN LED

LED position

"RUN": Modul

LED colour

grün

LED status display - LED 06

LED status

EtherCAT Error LED

LED position

"ERR": Modul

LED colour

rot

LED status display - LED 07

LED status

Diag-LED Feldbox

LED position

"Diag": Modul

LED colour

grün/rot

LED status display - LED 08

LED status

Power-LED Feldbox

LED position

"Pwr": Modul

LED colour

grün

Other data

Note (applications)

Sichere Feldbox mit dezentralen I/Os

Sprachfilter

Gerätebeschreibungsdateien

Download der aktuellen Version von Adobe Reader


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.

Generiert am: 02.01.2025, 08:01