EX-RF03
EX-RF03
Downloads
- Screw connection
- 3-4 (Contact labelling)
Ordering data
Product type description |
EX-RF03 |
Article number (order number) |
101195132 |
EAN (European Article Number) |
4030661460314 |
eCl@ss number, version 12.0 |
27-37-13-02 |
eCl@ss number, version 11.0 |
27-37-13-02 |
eCl@ss number, version 9.0 |
27-37-13-02 |
ETIM number, version 7.0 |
EC000041 |
ETIM number, version 6.0 |
EC000041 |
Approvals - Standards
Certificates |
TÜV cURus IEC Ex |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN 60079-11 EN 60079-14 EN 60079-31 |
Explosion protection zones |
1 21 2 22 |
Explosion protection category |
2G 2D |
Explosion protection designation |
D II 2G Ex ib IIC Gb D II 2D Ex ib IIIC Db |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 60204-1 EN IEC 60947-1 |
Housing material |
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Material of the identification label |
Plastic, Polyamide PA |
Gross weight |
9 g |
General data - Features
Number of normally open (NO) |
1 |
Safety classification |
Mission time |
20 Year(s) |
Safety classification - Safety outputs
B10D Normally-closed contact (NC) |
100,000 Operations |
Mechanical data
Installation instructions |
pluggable |
Mechanical life, minimum |
10,000,000 Operations |
Positive break travel |
2 mm |
Contact opening |
3 mm |
Tightening torque of the screw |
1 Nm |
Mounting flange position |
1 2 3 |
Mechanical data - Connection technique
Termination |
Screw terminals M20 x 1.5 |
Cable section, minimum |
2 x 1.0 mm², flexible |
Cable section, maximum |
2 x 2.5 mm² |
Tightening torque of Clips |
1 Nm |
Mechanical data - Dimensions
Length |
44 mm |
Width |
9 mm |
Height |
25.5 mm |
Ambient conditions
Degree of protection of the switch rooms |
IP40 |
Degree of protection of clips or terminals |
IP20 |
Resistance to vibrations |
5 g |
Restistance to shock |
30 g / 18 ms |
Resistant to vibration |
20 g / 10 ... 150 Hz |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
400 V |
Rated impulse withstand voltage Uimp |
4 kV |
Degree of pollution |
3 |
Electrical data
Thermal test current |
10 A |
Utilisation category AC-15 |
250 VAC |
Utilisation category AC-15 |
6 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
3 A |
Suitable for low-voltages |
≥ 5 V / ≥ 1 mA |
Switching element |
Normally open contact (NO) |
Switching principle |
Slow action |
Maximum switching frequency |
1,200 /h |
Material of the contacts, electrical |
Silver |
Contact labelling |
3-4 |
Language filter
Datasheet
IECEx certification
BG-test certificate
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Switch travel diagram
Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 2024-04-25, 1:12 p.m.