EX-CSS 8-16-2P+D-M-L-3G/D
EX-CSS 8-16-2P+D-M-L-3G/D
- Pre-wired cable 7-pole
- Comfortable diagnostics through sensor LED and electronic signalling output
- Thermoplastic enclosure
- Non-contact, coded electronic safety sensor for use in areas of zone
with gas and dust-explosion hazard - Category 3GD, ATEX Zone 2 and 22
- High repeat accuracy of the switching points
- Misaligned actuation possible
- Early warning when operating near the limit of the sensor's hysteris range
- Self-monitoring series-wiring of 16 sensors
- Suitable for applications up to PL e / SIL 3
Ordering data
| Note (Delivery capacity) |
Not available! |
| Product type description |
EX-CSS 8-16-2P+D-M-L-3G/D |
| Article number (order number) |
103003015 |
| EAN (European Article Number) |
4030661427195 |
| eCl@ss number, version 12.0 |
27-27-46-01 |
| eCl@ss number, version 11.0 |
27-27-24-03 |
| eCl@ss number, version 9.0 |
27-27-24-03 |
| ETIM number, version 7.0 |
EC001829 |
| ETIM number, version 6.0 |
EC001829 |
Explosion protection
| Explosion protection: regulations |
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31 |
| Explosion protection zones |
2 22 |
| Explosion protection category |
3G 3D |
| Explosion protection designation |
D II 3G Ex nA IIB T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
| Manufacturer declaration |
ATEX Zone 2 and 22 |
General data
| Working principle |
inductive |
| Housing construction form |
Block |
| Installation conditions (mechanical) |
not flush |
| Sensor topology |
Sensor for series wiring Individual sensor or end sensor in a series |
| Housing material |
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Active area |
Glass-fibre, reinforced thermoplastic |
| Reaction time, maximum |
30 ms |
| Duration of risk, maximum |
30 ms |
| Gross weight |
278 g |
General data - Features
| Short circuit detection |
Yes |
| Cross-circuit detection |
Yes |
| Safety functions |
Yes |
| Cascadable |
Yes |
| Integral system diagnostics, status |
Yes |
| Number of semi-conductor outputs with signaling function |
1 |
| Number of fail-safe digital outputs |
2 |
| Number of series-wiring of sensors |
16 |
| Safety classification |
| Standards |
EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
| Performance Level, up to |
e |
| Category |
4 |
| PFH value |
6.10 x 10⁻⁹ /h |
| Safety Integrity Level (SIL), suitable for applications in |
3 |
| Mission time |
20 Year(s) |
Mechanical data - Switching distances
| Switch distance, typical |
8 mm |
| Assured switching distance "ON" Sao |
6 mm |
| Assured switching distance "OFF" Sar |
11 mm |
| Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-3 |
| Hysteresis (Switching distance), maximum |
1 mm |
| Repeat accuracy R |
0.5 mm |
Mechanical data - Connection technique
| Length of cable |
2 m |
| Termination |
cable |
| Terminal connector, Input/Output |
7-pole |
| Wire cross-section |
0.25 mm2 |
| Wire cross-section |
23 AWG |
Mechanical data - Dimensions
| Length of sensor |
39.5 mm |
| Width of sensor |
55 mm |
| Height of sensor |
93 mm |
Ambient conditions
| Degree of protection |
IP65 IP67 |
| Ambient temperature |
-25 ... +50 °C |
| Storage and transport temperature |
-25 ... +85 °C |
| Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
| Restistance to shock |
30 g / 11 ms |
| Protection class |
II |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
32 VDC |
| Rated impulse withstand voltage Uimp |
0.8 kV |
| Overvoltage category |
III |
| Degree of pollution |
3 |
Electrical data
| Operating voltage |
24 VDC -15 % / +10 % (stabilised PELV power supply) |
| No-load supply current I0, typical |
50 mA |
| Rated operating voltage |
24 VDC |
| Operating current |
500 mA |
| Switching frequency, approx. |
3 Hz |
| Utilisation category DC-12 |
24 VDC / 0.05 A |
Electrical data - Safety digital outputs
| Design of control elements |
p-type |
| Voltage drop Ud, maximum |
0.5 V |
| Leakage current Ir, maximum |
0.5 mA |
| Voltage, Utilisation category DC-12 |
24 VDC |
| Current, Utilisation category DC-12 |
0.5 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
0.5 A |
Electrical data - Digital Output
| Design of control elements |
p-type |
Electrical data - Diagnostic outputs
| Voltage drop Ud, maximum |
4 V |
| Voltage, Utilisation category DC-12 |
24 VDC |
| Current, Utilisation category DC-12 |
0.05 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
0.05 A |
Status indication
| Note (LED switching conditions display) |
Multi-coloured LED: Green, Red, Yellow |
Scope of delivery
| Scope of delivery |
Actuator must be ordered separately. |
Accessory
| Recommendation (actuator) |
CST 16-1 |
Note
| Note (General) |
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.25 ms. Short-circuit recognition by the evaluation is not necessary. |
Language filter
Datasheet
Operating instructions and Declaration of conformity
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kexcsf01
| 661.3 kB | .jpg | 352.778 x 529.167 mm - 1000 x 1500 px - 72 dpi
| 53.1 kB | .png | 74.083 x 111.125 mm - 210 x 315 px - 72 dpi
| 40.4 kB | .jpg | 82.197 x 123.47200000000001 mm - 233 x 350 px - 72 dpi
| 29.7 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 4.9 MB | .png | 169.333 x 254 mm - 2000 x 3000 px - 300 dpi
| EU Declaration of Conformity | ![]() |
| Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
| Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
| Name of the component: | EX-CSS 8-16 |
| Type: | See ordering code |
| Marking: | D II 3G Ex nA IIB T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
| Description of the component: | Non-contact safety sensor |
| Relevant Directives: | Machinery Directive | 2006/42/EC |
| EMC-Directive | 2014/30/EU | |
| Explosion Protection Directive (ATEX) | 2014/34/EU | |
| RoHS-Directive | 2011/65/EU |
| Applied standards: | DIN EN 60947-5-3:2014 EN 60079-0:2012 + A11:2013 EN 60079-15:2010 EN 60079-31:2014 |
| Notified body, which approved the full quality assurance system, referred to Appendix IV, 2014/34/EU: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
| Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
| Place and date of issue: | Wuppertal, May 2, 2017 |
![]() |
| Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 08/03/2026, 11:49 pm