Product type description:

IFL (1)-(2)(3)-(4)(5)(6)(7)-(8)


(1)
10Switching distance 10 mm
15Switching distance 15 mm

(2)
30Cylinder, thread M30, metal
300Cylinder, thread M30, plastic

(3)
withoutStandard body
MMiniature body
LLong design

(4)
01Opener (NC)
10Normally open contact (NO)
10/01NO contact / NC contact with wiring compartment
111 NO contact / 1 NC contact antivalent

(5)
withoutCable
STMale connector
TConductor with strain relief
DDC 2-wire

(6)
withoutStandard connector version
2Alternative conector version

(7)
Nn-type
Pp-type

(8)
1310Can be used up to +110 C (for alternating current (AC) only)
2130Can be used up to +130 C, without LED switching conditions display
1766Can be used up to +110 C (for p-type or n-type only)
Not all component variants, which are possible according to this order code are available and/or technically feasible.
  • Design M30

Ordering data

Product type description

IFL 15-300L-10STP

Article number (order number)

101126983

EAN (European Article Number)

4030661050744

eCl@ss number, version 12.0

27-27-40-01

eCl@ss number, version 11.0

27-27-01-01

eCl@ss number, version 9.0

27-27-01-01

ETIM number, version 7.0

EC002714

ETIM number, version 6.0

EC002714

Approvals - Standards

Certificates

CCC

General data

Standards

DIN VDE 0660-208

EN IEC 60947-5-2

Housing construction form

Cylinder, thread

Installation conditions (mechanical)

not flush

Housing material

Plastic

Active area

Plastic

Material of the nuts

Plastic

Material of the washer

Perbunan

Gross weight

60 g

General data - Features

Integral system diagnostics, status

No

Cable sleeve

No

Mechanical data

Tightening torque of nuts, maximum

4 Nm

Mechanical data - Switching distances

Nominal switching distance Sn

15 mm

Note (switching distance)

All switching distances in accordance EN IEC 60947-5-2

Mechanical data - Connection technique

Length of cable

2 m

Termination

Screw terminals acc. DIN 42650

Mechanical data - Dimensions

ISO thread of the sensor

M30

width across flats

36 BK

Length of sensor

78 mm

Ambient conditions

Degree of protection

IP67

Resistance to vibrations

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Electrical data

Type of voltage range

DC

No-load supply current I0, typical

3 mA

Operating current

200 mA

Switching element

Normally open contact (NO)

Protection circuit integrated

inductive interference protection

Protection against polarity reversal

Surge protection

Max. fuse rating

Switching frequency, approx.

100 Hz

Electrical data - Digital Output

Voltage drop Ud, maximum

1.2 V

Current at Voltage drop Ud

0.2 A

Design of control elements

p-type

Note

Note (General)

Instead of nuts, a mounting clamp can be provided.

Language filter

Download the latest version of Adobe Reader

Diagram


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 24/06/2025, 11:03