IFL 15-333-11PK-1312
IFL 15-333-11PK-1312
Downloads
Product type description: IFL (1)-(2)-(3)(4)(5)(6) |
(1) | |
15 | Switching distance 15 mm |
20 | Switching distance 20 mm |
(2) | |
333 | Square design, 112 x 40 x 40 mm |
(3) | |
01 | Opener (NC) |
10 | Normally open contact (NO) |
10/01 | NO contact / NC contact with wiring compartment |
11 | 1 NO contact / 1 NC contact antivalent |
(4) | |
without | Cable |
D | DC 2-wire |
A | Alternating current/direct current AC/DC |
(5) | |
Y | Protection class IP65 |
Z | Protection class IP67 |
(6) | |
N | n-type |
P | p-type |
- Design 333
Ordering data
Product type description |
IFL 15-333-11PK-1312 |
Article number (order number) |
101115688 |
eCl@ss number, version 12.0 |
27-27-40-01 |
eCl@ss number, version 11.0 |
27-27-01-01 |
eCl@ss number, version 9.0 |
27-27-01-01 |
ETIM number, version 7.0 |
EC002714 |
ETIM number, version 6.0 |
EC002714 |
General data
Standards |
DIN VDE 0660-208 EN IEC 60947-5-2 |
Housing construction form |
Block |
Installation conditions (mechanical) |
flush |
Housing material |
Plastic |
Active area |
Plastic |
Material of the housing cover |
Luran |
Gross weight |
173 g |
General data - Features
Integral system diagnostics, status |
Yes |
Mechanical data - Switching distances
Nominal switching distance Sn |
15 mm |
Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-2 |
Mechanical data - Connection technique
Length of cable |
2 m |
Termination |
Screw terminals M20 x 1.5 |
Cable section, maximum |
2 x 1.5 mm² |
Mechanical data - Dimensions
Length of sensor |
112 mm |
Width of sensor |
40 mm |
Height of sensor |
40 mm |
Ambient conditions
Degree of protection |
IP65 |
Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
II |
Electrical data
Type of voltage range |
DC |
No-load supply current I0, typical |
5.5 mA |
Operating current |
400 mA |
Switching element |
NO contact and NC contact (antivalent) |
Protection circuit integrated |
inductive interference protection Max. fuse rating |
Switching frequency, approx. |
100 Hz |
Electrical data - Digital Output
Voltage drop Ud, maximum |
1.5 V |
Current at Voltage drop Ud |
0.4 A |
Design of control elements |
p-type |
Status indication
Note (Integral System Diagnostics, status ) |
yellow LED |
Note
Note (General) |
By repositioning the switch 5 different actuating directions can be selected. The selected actuating direction can be marked with a sticker. |
Language filter
Datasheet
Mounting and wiring instructions
EC Declaration of conformity
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 25/06/2025, 04:59