SD-I-U-EIP
SD-I-U-EIP
Downloads
- UNIVERSAL Gateway for the series-wiring of the diagnostic signals of safety
switchgear with integrated SD interface. - Comprehensive volumes of status and diagnostic data of the SD devices are transmitted to the control system through the field bus interface.
- Series-wiring of the diagnostic lines of max. 31 safety switchgear
- Series-wiring of different devices possible
- Reduced wiring efforts and costs as a result of the series-wiring of the safety channels and the diagnostic cables in the field.
- Automatic addressing of the safety switchgear in the SD interface
Ordering data
Product type description |
SD-I-U-EIP |
Article number (order number) |
101210747 |
EAN (European Article Number) |
4030661448893 |
eCl@ss number, version 12.0 |
27-23-02-06 |
eCl@ss number, version 11.0 |
27-23-02-06 |
eCl@ss number, version 9.0 |
27-23-02-08 |
ETIM number, version 7.0 |
EC001099 |
ETIM number, version 6.0 |
EC001099 |
Approvals - Standards
|
cULus |
General data
Gross weight |
340 g |
General data - Features
Integral system diagnostics, status |
Yes |
Number of LEDs |
1 |
Mechanical data
Mounting |
Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique
Termination |
Cage clamps |
Mechanical data - Dimensions
Width |
50 mm |
Height |
100 mm |
Depth |
80 mm |
Ambient conditions
Degree of protection of the enclosure |
IP20 |
Ambient temperature |
+0 ... +55 °C |
Storage and transport temperature |
-25 ... +75 °C |
Relative humidity, minimum |
30 % |
Relative humidity, maximum |
85 % |
Note (Relative humidity) |
non-condensing |
Resistance to vibrations |
10 ... 57 Hz, Amplitude 0.35 mm 57 ... 150 Hz, with 5 g |
Restistance to shock |
10 g |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 V |
Rated impulse withstand voltage Uimp |
0.5 kV |
Overvoltage category |
II |
Degree of pollution |
2 |
Electrical data
Operating voltage |
24 VDC -15 % / +20 % (stabilised PELV power supply) |
Rated operating voltage |
24 VDC |
Operating current |
500 mA |
Electrical data - Communication protocols
Feldbus Protokoll |
EtherNet IP |
Electrical data - Electromagnetic compatibility (EMC)
Electromagnetic compatibility |
EN 61000-4-2 EN 61000-4-4 EN 61000-4-5 |
Interfering radiation |
IEC 61000-6-4 (2002) |
EMC rating |
EN 61000-4-3 EN 61000-4-6 |
Other data
Note (applications) |
Safety sensor Guard system |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
Datasheet (provisional PDF)
Software (Download)
Brochure
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Wiring example
Application Note
ID: p-sd-i-u-eip
Video ID: SD-Interface-Mr-Safety
EU Declaration of Conformity |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | SD-I-U-… |
Type: | See ordering code |
Description of the component: | UNIVERSAL gateway for serial diagnostic (SD-I-U-..) |
Relevant Directives: | EMC-Directive | 2014/30/EU |
RoHS-Directive | 2011/65/EU |
Applied standards: | DIN EN 61000-6-2:2006 DIN EN 61000-6-4:2011 EN 61326-3-1:2008 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |