EX-BNS 250-11ZG-3GD 5M
EX-BNS 250-11ZG-3GD 5M
Produktbeteckning: EX-BNS 250-(1)Z(2)-(3)3G/D |
(1) | |
11 | 1 slutande kontakt (sl) /1 brytande kontakt (br) |
12 | 1 slutande kontakt (sl) /2 brytande kontakt (br) |
(2) | |
utan | Utan LED-statusindikering |
G | Med LED-statusindikering |
(3) | |
2187 | Individuellt kontaktuttag (utan LED-statusindikering) |
- Ex-zon 2 och 22
- Plasthus
- Okänslig mot felaktig inriktning på tvären
- inget mekaniskt slitage
Beställningsinformation
Produktbeteckning |
EX-BNS 250-11ZG-3GD 5M |
Artikelnummer (beställningsnummer) |
103045600 |
EAN (European Article Number) |
4030661628752 |
eCl@ss number, version 12.0 |
27-27-44-01 |
eCl@ss number, version 11.0 |
27-27-24-02 |
eCl@ss nummer, version 9.0 |
27-27-24-02 |
ETIM number, version 7.0 |
EC002544 |
ETIM number, version 6.0 |
EC002544 |
Explosionsskydd
Explosionsskydd: Föreskrifter |
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31 |
Ex-zoner |
2 22 |
Explosionsskyddad kategori |
3G 3D |
Explosionsskydd märkning |
D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
Manufacturer declaration |
ATEX Zone 2 and 22 |
Globala egenskaper
Kaplsing, dimensioner |
Block |
Monteringsvillkor (mekanisk) |
inte i jämnhöjd |
Kapslingens material |
Plast, glasfiberförstärkt termoplast |
Bruttovikt |
241 g |
Allmänna data - Egenskaper
Kodning |
Ja |
Integrerad indikering, allmänt |
Ja |
Prerequisite evaluation unit |
Ja |
Antal öppnare |
1 |
Antal slutare |
1 |
Antal kabelledare |
4 |
Klassificering
Standarder, föreskrifter |
EN ISO 13849-1 |
Mission time |
20 År |
Säkerhetsklassificering - säkerhetsutgångar
B10D-värde, NC/NO |
25 000 000 kopplingar |
Mekaniska data
Manövreringselement |
Magnetspole |
Slagenergi, maximum |
7 J |
Rörelseriktning |
Frontalt mot den aktiva ytan |
Mechanical data - Switching distances according EN IEC 60947-5-3
Säkra brytavstånd TILL |
4 mm |
Säkrat brytavstånd FRÅN |
14 mm |
Mechanical data - Connection technique
Kabelns längd |
5 m |
Anslutning, kontakt |
Kabel |
Ledararea |
0,25 mm2 |
Ledararea |
23 AWG |
Kabelmantelns material |
PVC |
Mekaniska data - mått
Sensorns längd |
13 mm |
Sensorns bredd |
33 mm |
Sensorns höjd |
25 mm |
Omgivningsförhållanden
Skyddsklass |
IP67 |
Ambient temperature |
-25 ... +70 °C |
Storage and transport temperature |
-25 ... +70 °C |
Vibrationstålig enligt EN 60068-2-6 |
10 … 55 Hz, Amplitud 1 mm |
tålighet mot chock |
30 g / 11 ms |
Elektriska data
Kopplingsspänning, maximum |
24 VDC |
Kopplingsström, maximum |
0,1 A |
Kopplingseffekt, maximum |
1 W |
Kopplingsdon |
1 slutande kontakt (sl), 1 brytande kontakter (br) |
Kopplingsfrekvens, maximum |
5 Hz |
Elektriska data - Digital utgång
Kopplingsutgång |
Övrigt, reedkontakter |
Statusindikering
Note (Integral System Diagnostics, status ) |
Lysdioden lyser när skyddsdörren är öppen. |
Leveransomfång
Leveransomfång |
Actuator must be ordered separately. |
Tillbehör
Rekommendation (aktiveringsdon) |
EX-BPS 250-3G/D |
Recommended safety switchgear |
SRB-E-301ST SRB-E-201LC |
Note
Note (General) |
Kontaktsymboler visas med skyddet i stäng tillstånd Kontaktkonfigurationen för versioner med eller utan LED är identisk. |
Språk filter
Datablad
Driftsinstruktion och EU-försäkran om överensstämmelse
Broschyr
SISTEMA-VDMA Bibliotek/Library
Ladda ned senaste versionen av Adobe reader
Produktbild (singelfoto i katalog)
Måttritning (grundkomponent)
Diagram
Karakteristisk kurva
UK Declaration of Conformity |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | EX-BNS 250 | EX-BPS 250 |
Type: | See ordering code |
Marking: | D II 3G Ex nC IIC T6 Gc D II 3D Ex tc IIIC T80°C Dc | D II 3G Ex h IIC T6 Gc D II 3D Ex h IIIC T80°C Dc |
Description of the component: | Coded safety-sensor with magnetic operating principle in combination with the SRB(-E) / PROTECT-SELECT / PSC1 safety-monitoring modules from Schmersal or an equivalent safety-oriented control system fulfilling the requirements of the EN 60947-5-3. |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN 60947-5-3:2013 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 EN ISO 80079-36:2016 EN ISO 80079-37:2016 |
Conformity with SI 2016/1107 (Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations) is declared by the manufacturer without involving a conformity assessment center. |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, November 10, 2022 |
Authorised signature Philip Schmersal Managing Director |
EU Declaration of Conformity |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | EX-BNS 250 | EX-BPS 250 |
Type: | See ordering code |
Marking: | D II 3G Ex nC IIC T6 Gc D II 3D Ex tc IIIC T80°C Dc | D II 3G Ex h IIC T6 Gc D II 3D Ex h IIIC T80°C Dc |
Description of the component: | Coded safety-sensor with magnetic operating principle in combination with the SRB(-E) / PROTECT-SELECT / PSC1 safety-monitoring modules from Schmersal or an equivalent safety-oriented control system fulfilling the requirements of the EN 60947-5-3. |
Relevant Directives: | Machinery Directive | 2006/42/EC |
Explosion Protection Directive (ATEX) | 2014/34/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 60947-5-3:2013 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 EN ISO 80079-36:2016 EN ISO 80079-37:2016 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Conformity with the explosion protection directive 2014/34/EU (ATEX) is declared by the manufacturer without involving a test center. |
Place and date of issue: | Wuppertal, May 10, 2022 |
Authorised signature Philip Schmersal Managing Director |
Schmersal Nordiska AB, F O Petersons gata 28, S-421 31 Västra Frölunda
Alla data och värden har kontrollerats noga. Bilder kan avvika från originalet. Ytterligare tekniska data finns i manualen. Tekniska ändringar och fel förbehålles.
Genererat den 2024-11-22 05:56