AST11 L-AS6
AST11 L-AS6
Downloads
Product type description: AST (1)(2)-AS(3)(4) |
(1) | |
02 | 1 NC contact / 1 NC contact |
11 | 1 NO contact / 1 NC contact |
(2) | |
ST | Connector M12 |
L | Connecting cable (2m) |
(3) | |
2 | Connecting cable 2 pole |
4 | Connecting cable 4 pole |
216 | Connecting cable 6 pole |
(4) | |
ST | Connector plug M12, Connecting cable 2- and 4-pole (optional) |
- Input module with cable (AS-i), length 2 m
- For sensors with NC / NO combination
- AS-i connection, Pre-wired cable, 4-pole
- Sensor connection, Pre-wired cable 2 m
- Solenoid supply 24 VDC (Aux)
- Magnetic drive through AS-Interface output
- NOTICE: Not available!
- Input module for 2 safe inputs for mechanical contacts
- Thermoplastic enclosure
- AS-Interface LED and status display
- 86,5 mm x 28 mm x 28 mm
- Long life
- Integrated AS-Interface
Ordering data
Note (Delivery capacity) |
Not available! |
Product type description |
AST11 L-AS6 |
Article number (order number) |
101176312 |
eCl@ss number, version 12.0 |
27-24-26-04 |
eCl@ss number, version 11.0 |
27-24-26-04 |
eCl@ss number, version 9.0 |
27-24-26-04 |
ETIM number, version 7.0 |
EC001599 |
ETIM number, version 6.0 |
EC001599 |
Approvals - Standards
|
cULus |
General data
Standards |
EN 50295 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 61508 |
Connector (electric) |
AS-i Terminal: Pre-wired cable, 4-pole Sensor connection: pre-wired cable 6-pole |
Housing material |
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
General data - Features
Cross-circuit detection |
Yes |
Integral system diagnostics, status |
Yes |
Number of inputs for NC |
1 |
Number of inputs for NO |
1 |
Number of pre-wired cable |
2 |
Safety classification |
Standards |
EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
2.04 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Mechanical data - Connection technique
Length of cable |
2 m |
Termination |
1 NO contacts/1 NC contact |
Wire cross-section |
0.23 mm2 |
Wire cross-section |
23 AWG |
Mechanical data - Dimensions
Diameter of sensor |
28 mm |
Height of sensor |
86.5 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-25 ... +55 °C |
Storage and transport temperature |
-25 ... +85 °C |
Relative humidity, minimum |
30 % |
Relative humidity, maximum |
95 % |
Note (Relative humidity) |
non-condensing |
Protection class |
II |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0.8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Current consumption |
50 mA |
Current consumption, maximum |
500 mA |
Electrical data - AS Interface
Rated operating voltage |
26.5 ... 31.6 VDC (Protection against polarity reversal) |
Electrical data - AS-Interface specification
AS-i Version |
V 2.1 |
AS-i Profile |
S-7.B.F.E |
AS-i, IO-Code |
0x7 |
AS-i, ID-Code |
0xB |
AS-i, ID-Code1 |
0xF |
AS-i, ID-Code2 |
0xE |
AS-i Input, Channel 1 |
Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 |
Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 |
Solenoid control |
AS-i Outputs, DO 1 |
No Function |
AS-i Outputs, DO 2 |
No Function |
AS-i Outputs, DO 3 |
No Function |
AS-i Parameter bits, P0 ... P3 |
No function |
Note (AS-i Parameter bits) |
Set the parameter outputs to "1111" (0xF) FID: periphery error |
AS-i Input module address |
0 |
Note (AS-i Input module address) |
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Status indication
Note (LED switching conditions display) |
(1) LED green: Supply voltage (2) LED red: Communication error (3) LED yellow : Enabling status |
Pin assignment
Connection |
AS-i connection |
PIN 1 |
Brown (AS interface +) |
PIN 2 |
White - (Aux -) |
PIN 3 |
Blue (AS interface −) |
PIN 4 |
Black - (Aux +) |
Connection |
Sensor connection |
PIN 1 |
Brown - Normally open contact (NO) |
PIN 2 |
Blue - Normally open contact (NO) |
PIN 3 |
White - Opener (NC) |
PIN 4 |
Black - Opener (NC) |
PIN 5 |
Red - Magnet (+) AUS |
PIN 6 |
Grey - Solenoid GND |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Diagram
Wiring example
Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 2024-11-26, 6:44 p.m.